Caracterizações físicas, químicas e de bioatividade de superfícies de titânio modificadas para aplicação biomédica
| Ano de defesa: | 2010 |
|---|---|
| Autor(a) principal: | |
| Orientador(a): | |
| Banca de defesa: | |
| Tipo de documento: | Tese |
| Tipo de acesso: | Acesso aberto |
| Idioma: | por |
| Instituição de defesa: |
Não Informado pela instituição
|
| Programa de Pós-Graduação: |
Não Informado pela instituição
|
| Departamento: |
Não Informado pela instituição
|
| País: |
Não Informado pela instituição
|
| Palavras-chave em Português: | |
| Link de acesso: | https://hdl.handle.net/1884/25989 |
Resumo: | Orientador: Prof. Dr. Carlos Maurício Lepienski |
| id |
UFPR_3560eb53a92347ff5018dd734b4834b2 |
|---|---|
| oai_identifier_str |
oai:acervodigital.ufpr.br:1884/25989 |
| network_acronym_str |
UFPR |
| network_name_str |
Repositório Institucional da UFPR |
| repository_id_str |
|
| spelling |
Foerster, Carlos EugênioUniversidade Federal do Paraná. Setor de Tecnologia. Programa de Pós-Graduação em Engenharia e Ciência dos Materiais - PIPELepienski, Carlos Mauricio, 1954-Souza, Gelson Biscaia de2024-12-12T13:40:56Z2024-12-12T13:40:56Z2010https://hdl.handle.net/1884/25989Orientador: Prof. Dr. Carlos Maurício LepienskiCoorientador: Prof. Dr. Carlos Eugênio FoersterTese (doutorado) - Universidade Federal do Paraná, Setor de Tecnologia, Programa de Pós-Graduaçao em Engenharia - PIPE. Defesa: Curitiba, 30/06/2010Bibliografia: fls. 217-229Área de concentração: Engenharia e ciência de materiaisResumo: Os objetivos deste trabalho estão focados em dois aspectos de interesse para a biomedicina, ambos direcionados à substituição de tecidos duros do organismo por próteses de titânio. O primeiro diz respeito à capacidade de osseointegração da prótese: investiga-se a potencialidade da técnica de implantação iônica de baixas energias (LEI), ou imersão em plasma, para se promover a bioatividade na superfície do titânio. No segundo objetivo, analisa-se a razão entre bioatividade e comportamento tribo-mecânico das superfícies de Ti modificadas por LEI, bem como do Ti modificado por outros tratamentos dedicados à osseointegração (tratamento alcalino - AT, tratamento alcalino e térmico - AHT, e oxidação anódica). Estes últimos (AT, AHT, oxidação anódica) foram tomados como referenciais de bioatividade para as superfícies tratadas por LEI. As amostras foram caracterizadas quanto aos elementos presentes na superfície (NRA e EDS), ao seu estado químico (XPS), à microestrutura (XRD e TF-XRD) e à morfologia (SEM e perfilometria). As propriedades mecânicas foram avaliadas em escala nanométrica por indentação instrumentada. O módulo de elasticidade (E) e a dureza (H) dos revestimentos, independentes dos efeitos do substrato, foram calculados através de métodos analíticos; os erros nas medidas de E e H em razão da rugosidade da superfície foram corrigidos pela análise da rigidez de contato. Os ensaios tribológicos foram realizados em nanoescala (resistência ao risco) e micro e miliescala (coeficiente de atrito e desgaste). Avaliou-se a bioatividade in vitro através de períodos de imersão de 14 a 30 dias em fluído corpóreo simulado (SBF). Tanto o AT quanto o AHT apresentaram elevada bioatividade in vitro; o tratamento térmico eleva significativamente a qualidade tribo-mecânica do revestimento, comparando-se o AT com o AHT. Porém, o filme de AHT é danificado ou removido sob risco com ponta Berkovich com cargas tão baixas quanto 5 mN; seu módulo de elasticidade é de apenas 2% do valor para o Ti de referência, e sua dureza é de menos de 1%. A oxidação anódica utilizando eletrólitos a base de Ca e P também promoveu uma elevada bioatividade in vitro, a qual foi atribuída à presença de Ti-OH e à morfologia da camada. Os valores de E da camada são similares aos valores para os tecidos ósseos (10-40 GPa), o que é importante para se garantir a compatibilidade mecânica do implante. Apesar da boa relação entre bioatividade e propriedades mecânicas, as camadas são frágeis sob carregamento normal e tangencial. A LEI foi empregada sobre o Ti utilizando-se espécies iônicas provenientes de plasmas de O2, 60%N2 40% H2 (nitretante), Ar, H2O+Ar, H2O+(60%N2 40% H2) e hidrogenação (H2), esta última isolada ou sucessiva aos demais tratamentos. A bioatividade não foi observada nestas superfícies nos testes em SBF, o que se atribuiu à energia dos íons no plasma, insuficiente para se aumentar, de modo significativo, a quantidade de ligações Ti-OH nas superfícies tratadas. O AHT, quando aplicado sobre o Ti previamente submetido à LEI, torna as superfícies bioativas, porém em menor grau comparado com o mesmo tratamento sobre o Ti. Assim como a bioatividade, a resistência em testes tribológicos também se reduz na seguinte ordem: hidrogenação - nitretação - oxidação (com H2O) - oxidação (com O2). Assim, diferentemente de informações da literatura, verificou-se que no tratamento alcalino o filme bioativo cresce preferencialmente a partir de reações com o Ti metálico, e menos da dissolução do TiO2. Em suma, o tratamento do Ti por LEI não é favorável à sua bioatividade. Os estudos aqui realizados também revelaram alguns fenômenos devidos à hidrogenação do titânio por LEI, ainda não reportados na literatura: (i) a fragilização da superfície do Ti e do Ti nitretado; (ii) o efeito de barreira dos nitretos à difusão do hidrogênio implantado; (iii) a desnitretação na região próxima à uperfície.Abstract: The present work is focused in two aspects concerning the replacement of hard tissues by titanium prosthesis, which are of interest to the biomedicine field. The first one regards the osseointegration capability: the potentiality of the low energy ion implantation (LEI) technique to produce bioactive Ti surfaces is investigated. In the second aim, the ratio between bioactivity and adequate tribo-mechanical behavior for implants are analyzed for LEI, as well as for other treatments dedicated to the osseointegration, namely the alkali treatment (AT), alkali-heat treatment (AHT) and anodic oxidation. The last ones (AT, AHT and anodic oxidation) were considered bioactivity referentials to the evaluation of the LEI treated surfaces. Samples were characterized regarding the elements presence and distribution at the surface (NRA and EDS), their chemical state (XPS), the structural features (XRD or TF-XRD) and the morphology (SEM and profilometry). The mechanical properties were obtained at nanoscale by instrumented indentation. The elastic modulus (E) and hardness (H) of the coatings, independent from the substrate effects, were calculated by analytical methods. The roughness effects on these properties were corrected by the contact stiffness analysis. Tribological assays were performed in nanoscale (scratch resistance) and micro and miliscale (friction coefficient and wear). The in vitro bioactivity was evaluated by soaking the samples in a simulated body fluid (SBF) during 14-30 days. The surfaces submitted to AT and AHT presented elevated in vitro bioactivity; the heating (in AHT) subsequent to the alkali treatment (in AT) significantly increases the tribo-mechanical features of the film. However, the AHT film is damaged or removed by loads as low as 5 mN; its elastic modulus is only 2% of the pristine Ti whereas hardness is less than 1%. Likewise, the anodic oxidation using Ca and P based electrolytes also promoted elevated in vitro bioactivity, which was attributed to the morphology and plenty of Ti-OH at the surface. The E values for the produced layer are similar to the values for the bone tissues (10-40 GPa). However, despite the good bioactivity and mechanical response, such anodic layers are brittle under normal and tangential loading. LEI treatments were performed on Ti by using ionic species originated from the following plasmas: O2; 60%N2 40% H2 (nitriding atmosphere); Ar; H2O+Ar; H2O+(60%N2 40% H2); and hydrogenation (H2), the latter one used alone or successive to the former treatments. After SBF assays, bioactivity was not observed on the surfaces submitted to LEI. This fact was attributed to the low energy delivered to the ion in this process, which is not enough to promote a significant increase in the Ti-OH bonds amount at the surface. On the other hand, the AHT performed on Ti after the LEI processes became such surfaces bioactive, however, in a lesser degree than AHT used separately. In these LEI + AHT surfaces, the bioactivity and tribological performance are diminished, in comparing to the Ti submitted only to AHT, in the following sequence: hydrogenation - nitriding - oxidation (by H2O) - oxidation (by O2). Thus, differently from information in literature, from these results it was verified that the bioactive film growth in the alkali environment is strongly dependent on the reactions with metallic Ti at surface, whereas the dissolution of TiO2 is a less important reaction. Therefore, the LEI treatments are not favorable to promote bioactivity on Ti surfaces. The studies here conducted also disclosed other phenomena running at the Ti surface by the LEI hydrogenation, which had not yet been reported in literature: (i) the brittleness of Ti and nitrided Ti surfaces; (ii) the barrier effect by the nitride precipitates to the diffusion of implanted hydrogen; (iii) the denitriding at very near surface region.230f. : il. [algumas color.], grafs., tabs.application/pdfDisponível em formato digitalTitânio - Propriedades mecânicasBiomedicinaImplantes dentários endoósseosPrótese dentáriaEngenharia de Materiais e MetalurgiaCaracterizações físicas, químicas e de bioatividade de superfícies de titânio modificadas para aplicação biomédicainfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisporreponame:Repositório Institucional da UFPRinstname:Universidade Federal do Paraná (UFPR)instacron:UFPRinfo:eu-repo/semantics/openAccessORIGINALTeseDout_GBdeSouza_UFPR_2010.pdfapplication/pdf21920338https://acervodigital.ufpr.br/bitstream/1884/25989/1/TeseDout_GBdeSouza_UFPR_2010.pdf3d7e245e55d587f881d18478f044fb9bMD51open accessTEXTTeseDout_GBdeSouza_UFPR_2010.pdf.txtExtracted Texttext/plain504857https://acervodigital.ufpr.br/bitstream/1884/25989/2/TeseDout_GBdeSouza_UFPR_2010.pdf.txt461e82e87b7bc6c506ac219b1a5d7e5bMD52open accessTHUMBNAILTeseDout_GBdeSouza_UFPR_2010.pdf.jpgGenerated Thumbnailimage/jpeg1217https://acervodigital.ufpr.br/bitstream/1884/25989/3/TeseDout_GBdeSouza_UFPR_2010.pdf.jpg1f9e0ae0218cf1ce03d8034349bd749dMD53open access1884/259892024-12-12 10:40:56.957open accessoai:acervodigital.ufpr.br:1884/25989Repositório InstitucionalPUBhttp://acervodigital.ufpr.br/oai/requestinformacaodigital@ufpr.bropendoar:3082024-12-12T13:40:56Repositório Institucional da UFPR - Universidade Federal do Paraná (UFPR)false |
| dc.title.pt_BR.fl_str_mv |
Caracterizações físicas, químicas e de bioatividade de superfícies de titânio modificadas para aplicação biomédica |
| title |
Caracterizações físicas, químicas e de bioatividade de superfícies de titânio modificadas para aplicação biomédica |
| spellingShingle |
Caracterizações físicas, químicas e de bioatividade de superfícies de titânio modificadas para aplicação biomédica Souza, Gelson Biscaia de Titânio - Propriedades mecânicas Biomedicina Implantes dentários endoósseos Prótese dentária Engenharia de Materiais e Metalurgia |
| title_short |
Caracterizações físicas, químicas e de bioatividade de superfícies de titânio modificadas para aplicação biomédica |
| title_full |
Caracterizações físicas, químicas e de bioatividade de superfícies de titânio modificadas para aplicação biomédica |
| title_fullStr |
Caracterizações físicas, químicas e de bioatividade de superfícies de titânio modificadas para aplicação biomédica |
| title_full_unstemmed |
Caracterizações físicas, químicas e de bioatividade de superfícies de titânio modificadas para aplicação biomédica |
| title_sort |
Caracterizações físicas, químicas e de bioatividade de superfícies de titânio modificadas para aplicação biomédica |
| author |
Souza, Gelson Biscaia de |
| author_facet |
Souza, Gelson Biscaia de |
| author_role |
author |
| dc.contributor.other.pt_BR.fl_str_mv |
Foerster, Carlos Eugênio Universidade Federal do Paraná. Setor de Tecnologia. Programa de Pós-Graduação em Engenharia e Ciência dos Materiais - PIPE |
| dc.contributor.advisor1.fl_str_mv |
Lepienski, Carlos Mauricio, 1954- |
| dc.contributor.author.fl_str_mv |
Souza, Gelson Biscaia de |
| contributor_str_mv |
Lepienski, Carlos Mauricio, 1954- |
| dc.subject.por.fl_str_mv |
Titânio - Propriedades mecânicas Biomedicina Implantes dentários endoósseos Prótese dentária Engenharia de Materiais e Metalurgia |
| topic |
Titânio - Propriedades mecânicas Biomedicina Implantes dentários endoósseos Prótese dentária Engenharia de Materiais e Metalurgia |
| description |
Orientador: Prof. Dr. Carlos Maurício Lepienski |
| publishDate |
2010 |
| dc.date.issued.fl_str_mv |
2010 |
| dc.date.accessioned.fl_str_mv |
2024-12-12T13:40:56Z |
| dc.date.available.fl_str_mv |
2024-12-12T13:40:56Z |
| dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
| dc.type.driver.fl_str_mv |
info:eu-repo/semantics/doctoralThesis |
| format |
doctoralThesis |
| status_str |
publishedVersion |
| dc.identifier.uri.fl_str_mv |
https://hdl.handle.net/1884/25989 |
| url |
https://hdl.handle.net/1884/25989 |
| dc.language.iso.fl_str_mv |
por |
| language |
por |
| dc.relation.pt_BR.fl_str_mv |
Disponível em formato digital |
| dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
230f. : il. [algumas color.], grafs., tabs. application/pdf |
| dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UFPR instname:Universidade Federal do Paraná (UFPR) instacron:UFPR |
| instname_str |
Universidade Federal do Paraná (UFPR) |
| instacron_str |
UFPR |
| institution |
UFPR |
| reponame_str |
Repositório Institucional da UFPR |
| collection |
Repositório Institucional da UFPR |
| bitstream.url.fl_str_mv |
https://acervodigital.ufpr.br/bitstream/1884/25989/1/TeseDout_GBdeSouza_UFPR_2010.pdf https://acervodigital.ufpr.br/bitstream/1884/25989/2/TeseDout_GBdeSouza_UFPR_2010.pdf.txt https://acervodigital.ufpr.br/bitstream/1884/25989/3/TeseDout_GBdeSouza_UFPR_2010.pdf.jpg |
| bitstream.checksum.fl_str_mv |
3d7e245e55d587f881d18478f044fb9b 461e82e87b7bc6c506ac219b1a5d7e5b 1f9e0ae0218cf1ce03d8034349bd749d |
| bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 |
| repository.name.fl_str_mv |
Repositório Institucional da UFPR - Universidade Federal do Paraná (UFPR) |
| repository.mail.fl_str_mv |
informacaodigital@ufpr.br |
| _version_ |
1847526073788530688 |