Determinação de contaminates inorgânicos em nanotubos de carbono por ICP-OES e ICP-MS

Detalhes bibliográficos
Ano de defesa: 2016
Autor(a) principal: Krzyzaniak, Sindy Raquel lattes
Orientador(a): Mello, Paola de Azevedo lattes
Banca de defesa: Mortari, Sergio Roberto lattes, Flores, Érico Marlon de Moraes lattes
Tipo de documento: Dissertação
Tipo de acesso: Acesso aberto
Idioma: por
Instituição de defesa: Universidade Federal de Santa Maria
Centro de Ciências Naturais e Exatas
Programa de Pós-Graduação: Programa de Pós-Graduação em Química
Departamento: Química
País: Brasil
Palavras-chave em Português:
Área do conhecimento CNPq:
Link de acesso: http://repositorio.ufsm.br/handle/1/18056
Resumo: In this work, microwave-assisted wet digestion using the single reaction chamber (MAWD-SRC) and microwave-induced combustion (MIC) methods were investigated for the decomposition of carbon nanotubes (CNTs) and further determination of inorganic contaminants by inductively coupled plasma optical emission spectrometry (ICP-OES) and by inductively coupled plasma mass spectrometry (ICP-MS). Initially, the CNTs were decomposed by microwave-assisted wet digestion (MAWD) and the results obtained were considered as reference values. Parameters investigated for MAWD-SRC were the irradiation temperature (220 to 270 °C), the mass of CNT (25 to 300 mg) and the composition of digestion mixture (HNO3 and H2O2). Quantitative recoveries were obtained for Al, As, Ca, Cd, Co, Cr, Fe, La, Mg, Mn, Mo, Ni, Pb, V and Zn, using 275 mg of CNT, 6 mL of 14.4 mol L-1 HNO3 and 0.5 mL of 30% H2O2 with an irradiation program of 65 min. Using the optimized conditions, the results obtained after the decomposition of CNTs by MAWD-SRC, presented no statistical difference when compared with those obtained using the reference method (MAWD). The accuracy of MAWD-SRC method was also evaluated through the determination of some elements by neutron activation analysis (NAA) and also by high resolution continuum source graphite furnace atomic absorption spectrometry with direct solid sampling (DSS-HR-CS-GF AAS) and no statistical difference between the results were observed. In addition, the results obtained for a certified reference material (CRM) of SWCNT presented no difference in relation to the certified values. Parameters of MIC method, such as the mass of CNT (25 to 500 mg), the concentration of absorbing solutions (1, 4, 7 e 14.4 mol L-1 of HNO3), the acid mixture (HNO3+HCl in proportion 3+1 and 1+1) and the reflux time (5 to 15 min) were optimized. For quantitative recoveries of all analytes using MIC, 15 min of reflux using the acid mixture of HNO3+HCl (3+1) and decomposition of up to 100 mg of CNT were necessary. Using the optimized conditions, no statistical difference was observed between the results obtained by reference method (MAWD) and by DSS-HR-CS-GF AAS.
id UFSM_4272d53b31459d1b04c5daaf970fb989
oai_identifier_str oai:repositorio.ufsm.br:1/18056
network_acronym_str UFSM
network_name_str Biblioteca Digital de Teses e Dissertações do UFSM
repository_id_str
spelling 2019-08-28T14:17:41Z2019-08-28T14:17:41Z2016-03-05http://repositorio.ufsm.br/handle/1/18056In this work, microwave-assisted wet digestion using the single reaction chamber (MAWD-SRC) and microwave-induced combustion (MIC) methods were investigated for the decomposition of carbon nanotubes (CNTs) and further determination of inorganic contaminants by inductively coupled plasma optical emission spectrometry (ICP-OES) and by inductively coupled plasma mass spectrometry (ICP-MS). Initially, the CNTs were decomposed by microwave-assisted wet digestion (MAWD) and the results obtained were considered as reference values. Parameters investigated for MAWD-SRC were the irradiation temperature (220 to 270 °C), the mass of CNT (25 to 300 mg) and the composition of digestion mixture (HNO3 and H2O2). Quantitative recoveries were obtained for Al, As, Ca, Cd, Co, Cr, Fe, La, Mg, Mn, Mo, Ni, Pb, V and Zn, using 275 mg of CNT, 6 mL of 14.4 mol L-1 HNO3 and 0.5 mL of 30% H2O2 with an irradiation program of 65 min. Using the optimized conditions, the results obtained after the decomposition of CNTs by MAWD-SRC, presented no statistical difference when compared with those obtained using the reference method (MAWD). The accuracy of MAWD-SRC method was also evaluated through the determination of some elements by neutron activation analysis (NAA) and also by high resolution continuum source graphite furnace atomic absorption spectrometry with direct solid sampling (DSS-HR-CS-GF AAS) and no statistical difference between the results were observed. In addition, the results obtained for a certified reference material (CRM) of SWCNT presented no difference in relation to the certified values. Parameters of MIC method, such as the mass of CNT (25 to 500 mg), the concentration of absorbing solutions (1, 4, 7 e 14.4 mol L-1 of HNO3), the acid mixture (HNO3+HCl in proportion 3+1 and 1+1) and the reflux time (5 to 15 min) were optimized. For quantitative recoveries of all analytes using MIC, 15 min of reflux using the acid mixture of HNO3+HCl (3+1) and decomposition of up to 100 mg of CNT were necessary. Using the optimized conditions, no statistical difference was observed between the results obtained by reference method (MAWD) and by DSS-HR-CS-GF AAS.Neste trabalho, métodos de decomposição por via úmida assistida por radiação micro-ondas em câmara única de reação (MAWD-SRC) e de combustão-iniciada por micro-ondas (MIC) foram investigados para a decomposição de nanotubos de carbono (CNTs) e posterior determinação de contaminantes inorgânicos por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP-OES) e espectrometria de massa com plasma indutivamente acoplado (ICP-MS). Inicialmente, os CNTs foram decompostos por decomposição por via úmida assistida por radiação micro-ondas (MAWD) e os resultados obtidos empregando este método foram considerados como valores de referência. Na avaliação do método por MAWD-SRC foram avaliadas a temperatura de irradiação (220 a 270 °C), a massa de CNT (25 a 300 mg) e a composição da solução de decomposição (HNO3 e H2O2). Recuperações quantitativas foram obtidas para Al, As, Ca, Cd, Co, Cr, Fe, La, Mg, Mn, Mo, Ni, Pb, V e Zn, utilizando 275 mg de CNT, 6 mL de HNO3 14,4 mol L-1 + 0,5 mL de H2O2 30% como solução de decomposição, com um programa de irradiação de 65 min. Utilizando as condições otimizadas, os resultados obtidos após decomposição dos CNTs por MAWD-SRC não apresentaram diferença estatística significativa quando comparados com aqueles obtidos empregando o método de referência (MAWD). A exatidão do método de MAWD-SRC também foi avaliada para alguns elementos utilizando a análise por ativação neutrônica (NAA) e a espectrometria de absorção atômica de alta resolução com fonte contínua e forno de grafite com amostragem direta de sólidos (DSS-HR-CS-GF AAS) e não foram observadas diferenças estatísticas significativas entre os resultados obtidos. Além disso, os resultados obtidos para o material de referência certificado (CRM) de SWCNT não apresentaram diferença em relação aos valores certificados. Na avaliação da MIC, foram avaliados parâmetros como a massa de CNT (25 a 500 mg), a concentração da solução absorvedora (1, 4, 7 e 14,4 mol L-1 de HNO3), a mistura de ácidos (HNO3+HCl na proporção 3+1 e 1+1) e o tempo de refluxo (5 a 15 min). Para a recuperação quantitativa de todos os analitos empregando a MIC, foram necessários 15 min de refluxo utilizando uma mistura de HNO3+HCl (3+1) como solução absorvedora e decomposição de até 100 mg de CNT. Os resultados obtidos utilizando as condições otimizadas, não apresentaram diferença estatística significativa quando comparados com os resultados obtidos pelo método de referência (MAWD) e por DSS-HR-CS-GF AAS.Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPqporUniversidade Federal de Santa MariaCentro de Ciências Naturais e ExatasPrograma de Pós-Graduação em QuímicaUFSMBrasilQuímicaAttribution-NonCommercial-NoDerivatives 4.0 Internationalhttp://creativecommons.org/licenses/by-nc-nd/4.0/info:eu-repo/semantics/openAccessMétodos de decomposição por via úmida assistida por radiação micro-ondas em câmara única de reação (MAWD-SRC)Combustão-iniciada por micro-ondas (MIC)Decomposição de nanotubos de carbono (CNTs)Determinação de contaminantes inorgânicos por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP-OES)Espectrometria de massa com plasma indutivamente acoplado (ICP-MS)CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICADeterminação de contaminates inorgânicos em nanotubos de carbono por ICP-OES e ICP-MSinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisMello, Paola de Azevedohttp://lattes.cnpq.br/2189500441942469Mortari, Sergio Robertohttp://lattes.cnpq.br/7784609477475171Flores, Érico Marlon de Moraeshttp://lattes.cnpq.br/7167629055579212http://lattes.cnpq.br/9088666879040816Krzyzaniak, Sindy Raquel1006000000006000128b934-4b3f-43d6-8526-fb278da0f673a866c1af-fc31-48d2-99f7-dada20cc9415b4d0ba10-19c4-43bb-8e88-bb2ae6aa3e1b62862614-b588-40e1-9d9a-b355c8ba3a6ereponame:Biblioteca Digital de Teses e Dissertações do UFSMinstname:Universidade Federal de Santa Maria (UFSM)instacron:UFSMORIGINALDIS_PPGQUIMICA_2016_KRZYZANIAK_SINDY.pdfDIS_PPGQUIMICA_2016_KRZYZANIAK_SINDY.pdfDissertação de Mestradoapplication/pdf1430086http://repositorio.ufsm.br/bitstream/1/18056/1/DIS_PPGQUIMICA_2016_KRZYZANIAK_SINDY.pdf6fbbb5e7b01e58710e36820cfed9cbd5MD51CC-LICENSElicense_rdflicense_rdfapplication/rdf+xml; charset=utf-8805http://repositorio.ufsm.br/bitstream/1/18056/2/license_rdf4460e5956bc1d1639be9ae6146a50347MD52LICENSElicense.txtlicense.txttext/plain; charset=utf-81956http://repositorio.ufsm.br/bitstream/1/18056/3/license.txt2f0571ecee68693bd5cd3f17c1e075dfMD53TEXTDIS_PPGQUIMICA_2016_KRZYZANIAK_SINDY.pdf.txtDIS_PPGQUIMICA_2016_KRZYZANIAK_SINDY.pdf.txtExtracted texttext/plain178031http://repositorio.ufsm.br/bitstream/1/18056/4/DIS_PPGQUIMICA_2016_KRZYZANIAK_SINDY.pdf.txt553ae0fe9a704a6e23f394add0b008f3MD54THUMBNAILDIS_PPGQUIMICA_2016_KRZYZANIAK_SINDY.pdf.jpgDIS_PPGQUIMICA_2016_KRZYZANIAK_SINDY.pdf.jpgIM Thumbnailimage/jpeg4335http://repositorio.ufsm.br/bitstream/1/18056/5/DIS_PPGQUIMICA_2016_KRZYZANIAK_SINDY.pdf.jpga19cf463e7505c9d1f5a2c6877502942MD551/180562022-06-01 09:36:18.603oai:repositorio.ufsm.br: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 Digital de Teses e Dissertaçõeshttps://repositorio.ufsm.br/ONGhttps://repositorio.ufsm.br/oai/requestatendimento.sib@ufsm.br||tedebc@gmail.comopendoar:2022-06-01T12:36:18Biblioteca Digital de Teses e Dissertações do UFSM - Universidade Federal de Santa Maria (UFSM)false
dc.title.por.fl_str_mv Determinação de contaminates inorgânicos em nanotubos de carbono por ICP-OES e ICP-MS
title Determinação de contaminates inorgânicos em nanotubos de carbono por ICP-OES e ICP-MS
spellingShingle Determinação de contaminates inorgânicos em nanotubos de carbono por ICP-OES e ICP-MS
Krzyzaniak, Sindy Raquel
Métodos de decomposição por via úmida assistida por radiação micro-ondas em câmara única de reação (MAWD-SRC)
Combustão-iniciada por micro-ondas (MIC)
Decomposição de nanotubos de carbono (CNTs)
Determinação de contaminantes inorgânicos por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP-OES)
Espectrometria de massa com plasma indutivamente acoplado (ICP-MS)
CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA
title_short Determinação de contaminates inorgânicos em nanotubos de carbono por ICP-OES e ICP-MS
title_full Determinação de contaminates inorgânicos em nanotubos de carbono por ICP-OES e ICP-MS
title_fullStr Determinação de contaminates inorgânicos em nanotubos de carbono por ICP-OES e ICP-MS
title_full_unstemmed Determinação de contaminates inorgânicos em nanotubos de carbono por ICP-OES e ICP-MS
title_sort Determinação de contaminates inorgânicos em nanotubos de carbono por ICP-OES e ICP-MS
author Krzyzaniak, Sindy Raquel
author_facet Krzyzaniak, Sindy Raquel
author_role author
dc.contributor.advisor1.fl_str_mv Mello, Paola de Azevedo
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/2189500441942469
dc.contributor.referee1.fl_str_mv Mortari, Sergio Roberto
dc.contributor.referee1Lattes.fl_str_mv http://lattes.cnpq.br/7784609477475171
dc.contributor.referee2.fl_str_mv Flores, Érico Marlon de Moraes
dc.contributor.referee2Lattes.fl_str_mv http://lattes.cnpq.br/7167629055579212
dc.contributor.authorLattes.fl_str_mv http://lattes.cnpq.br/9088666879040816
dc.contributor.author.fl_str_mv Krzyzaniak, Sindy Raquel
contributor_str_mv Mello, Paola de Azevedo
Mortari, Sergio Roberto
Flores, Érico Marlon de Moraes
dc.subject.por.fl_str_mv Métodos de decomposição por via úmida assistida por radiação micro-ondas em câmara única de reação (MAWD-SRC)
Combustão-iniciada por micro-ondas (MIC)
Decomposição de nanotubos de carbono (CNTs)
Determinação de contaminantes inorgânicos por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP-OES)
Espectrometria de massa com plasma indutivamente acoplado (ICP-MS)
topic Métodos de decomposição por via úmida assistida por radiação micro-ondas em câmara única de reação (MAWD-SRC)
Combustão-iniciada por micro-ondas (MIC)
Decomposição de nanotubos de carbono (CNTs)
Determinação de contaminantes inorgânicos por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP-OES)
Espectrometria de massa com plasma indutivamente acoplado (ICP-MS)
CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA
dc.subject.cnpq.fl_str_mv CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA
description In this work, microwave-assisted wet digestion using the single reaction chamber (MAWD-SRC) and microwave-induced combustion (MIC) methods were investigated for the decomposition of carbon nanotubes (CNTs) and further determination of inorganic contaminants by inductively coupled plasma optical emission spectrometry (ICP-OES) and by inductively coupled plasma mass spectrometry (ICP-MS). Initially, the CNTs were decomposed by microwave-assisted wet digestion (MAWD) and the results obtained were considered as reference values. Parameters investigated for MAWD-SRC were the irradiation temperature (220 to 270 °C), the mass of CNT (25 to 300 mg) and the composition of digestion mixture (HNO3 and H2O2). Quantitative recoveries were obtained for Al, As, Ca, Cd, Co, Cr, Fe, La, Mg, Mn, Mo, Ni, Pb, V and Zn, using 275 mg of CNT, 6 mL of 14.4 mol L-1 HNO3 and 0.5 mL of 30% H2O2 with an irradiation program of 65 min. Using the optimized conditions, the results obtained after the decomposition of CNTs by MAWD-SRC, presented no statistical difference when compared with those obtained using the reference method (MAWD). The accuracy of MAWD-SRC method was also evaluated through the determination of some elements by neutron activation analysis (NAA) and also by high resolution continuum source graphite furnace atomic absorption spectrometry with direct solid sampling (DSS-HR-CS-GF AAS) and no statistical difference between the results were observed. In addition, the results obtained for a certified reference material (CRM) of SWCNT presented no difference in relation to the certified values. Parameters of MIC method, such as the mass of CNT (25 to 500 mg), the concentration of absorbing solutions (1, 4, 7 e 14.4 mol L-1 of HNO3), the acid mixture (HNO3+HCl in proportion 3+1 and 1+1) and the reflux time (5 to 15 min) were optimized. For quantitative recoveries of all analytes using MIC, 15 min of reflux using the acid mixture of HNO3+HCl (3+1) and decomposition of up to 100 mg of CNT were necessary. Using the optimized conditions, no statistical difference was observed between the results obtained by reference method (MAWD) and by DSS-HR-CS-GF AAS.
publishDate 2016
dc.date.issued.fl_str_mv 2016-03-05
dc.date.accessioned.fl_str_mv 2019-08-28T14:17:41Z
dc.date.available.fl_str_mv 2019-08-28T14:17:41Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://repositorio.ufsm.br/handle/1/18056
url http://repositorio.ufsm.br/handle/1/18056
dc.language.iso.fl_str_mv por
language por
dc.relation.cnpq.fl_str_mv 100600000000
dc.relation.confidence.fl_str_mv 600
dc.relation.authority.fl_str_mv 0128b934-4b3f-43d6-8526-fb278da0f673
a866c1af-fc31-48d2-99f7-dada20cc9415
b4d0ba10-19c4-43bb-8e88-bb2ae6aa3e1b
62862614-b588-40e1-9d9a-b355c8ba3a6e
dc.rights.driver.fl_str_mv Attribution-NonCommercial-NoDerivatives 4.0 International
http://creativecommons.org/licenses/by-nc-nd/4.0/
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Attribution-NonCommercial-NoDerivatives 4.0 International
http://creativecommons.org/licenses/by-nc-nd/4.0/
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv Universidade Federal de Santa Maria
Centro de Ciências Naturais e Exatas
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Química
dc.publisher.initials.fl_str_mv UFSM
dc.publisher.country.fl_str_mv Brasil
dc.publisher.department.fl_str_mv Química
publisher.none.fl_str_mv Universidade Federal de Santa Maria
Centro de Ciências Naturais e Exatas
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações do UFSM
instname:Universidade Federal de Santa Maria (UFSM)
instacron:UFSM
instname_str Universidade Federal de Santa Maria (UFSM)
instacron_str UFSM
institution UFSM
reponame_str Biblioteca Digital de Teses e Dissertações do UFSM
collection Biblioteca Digital de Teses e Dissertações do UFSM
bitstream.url.fl_str_mv http://repositorio.ufsm.br/bitstream/1/18056/1/DIS_PPGQUIMICA_2016_KRZYZANIAK_SINDY.pdf
http://repositorio.ufsm.br/bitstream/1/18056/2/license_rdf
http://repositorio.ufsm.br/bitstream/1/18056/3/license.txt
http://repositorio.ufsm.br/bitstream/1/18056/4/DIS_PPGQUIMICA_2016_KRZYZANIAK_SINDY.pdf.txt
http://repositorio.ufsm.br/bitstream/1/18056/5/DIS_PPGQUIMICA_2016_KRZYZANIAK_SINDY.pdf.jpg
bitstream.checksum.fl_str_mv 6fbbb5e7b01e58710e36820cfed9cbd5
4460e5956bc1d1639be9ae6146a50347
2f0571ecee68693bd5cd3f17c1e075df
553ae0fe9a704a6e23f394add0b008f3
a19cf463e7505c9d1f5a2c6877502942
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
MD5
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações do UFSM - Universidade Federal de Santa Maria (UFSM)
repository.mail.fl_str_mv atendimento.sib@ufsm.br||tedebc@gmail.com
_version_ 1793239993494274048