Contribuições para o desenvolvimento de método por GCxGC para a análise de nitro-HPAs em material particulado no ar

Detalhes bibliográficos
Ano de defesa: 2013
Autor(a) principal: Silvana Odete Pisani
Orientador(a): Lilian Rothschild Franco de Carvalho
Banca de defesa: Fabio Augusto, Claudimir Lucio do Lago, Bruno Spinosa de Martinis, Jorge Cesar Masini
Tipo de documento: Tese
Tipo de acesso: Acesso aberto
Idioma: por
Instituição de defesa: Universidade de São Paulo
Programa de Pós-Graduação: Química
Departamento: Não Informado pela instituição
País: BR
Link de acesso: https://doi.org/10.11606/T.46.2013.tde-05082013-155917
Resumo: Os hidrocarbonetos policíclicos aromáticos nitrados (nitro-HPAs) são potencialmente genotóxicos, por isso existe um grande interesse na determinação analítica desses compostos no material particulado no ar. Os nitro-PAHs são emitidos diretamente para a atmosfera pela combustão incompleta ou podem ser formados in situ a partir dos HPAs precursores. Neste trabalho, são apresentados os resultados obtidos no desenvolvimento de um método de análise de nitro-HPAs (1-nitronaftaleno, 2-nitronaftaleno, 1-nitropireno, 2-nitropireno, 2-nitrofluoranteno, 3-nitrofluoranteno, 1,3-dinitropireno, 1,6- dinitropireno, 2-nitrofluoreno, 6-nitrocriseno, 7-nitrobenzo(a)antraceno, 9- nitroantraceno e 9-nitrofenantreno) por GCxGC. A separação destes compostos por GCxGC pode simplificar a etapa de pré-tratamento do extrato orgânico oriundo do material particulado no ar. A GCxGC promove a separação em duas colunas com mecanismos de separação diferentes, conectadas em série, o que resulta em uma capacidade de separação maior. O sistema GCxGC empregado neste trabalho possui um injetor com programação de temperatura (PTV), um modulador criogênico de dois jatos de CO2 líquido (Dual Jet) e um detector por ionização em chama (FID). A separação foi feita empregando a fase estacionária apolar 5% fenil polisilfenilene siloxano na primeira coluna (30 m / 0,25 mm / 0,25 µm) e a semipolar 14% cianopropilfenil polisiloxano na segunda coluna (1 m / 0,10 mm / 0,10 µm). Diferentes condições cromatográficas foram testadas, como: programação de temperatura no PTV, de 40-90ºC até 350ºC, com taxa de aquecimento de 2,2 e 14,5ºC/s; programação de temperatura no forno, de 40-90ºC até 300ºC, com taxa de aquecimento de 2, 2,5 e 3ºC/min; períodos de modulação de 3, 4 e 5s. O volume injetado foi 2µL, no modo splitless; a vazão do gás de arraste (He) foi constante e igual a 1 mL/min e o detector FID foi operado em 120 Hz. As larguras de pico medidas em 10% da altura variaram de 167 a 350ms para 1- nitronaftaleno e 6-nitrocriseno, respectivamente, e a capacidade de pico para o conjunto de colunas de separação usado foi estimada em cerca de 9800. Parâmetros de validação, tais como os limites de detecção (200 a 500 ng/mL) e de quantificação (650 a 1600 ng/mL) para alguns nitro-HPAs foram determinados. Para a quantificação, foram testados os métodos por padronização interna e externa, sendo que, através dos resultados deste trabalho, pode-se mostrar que a determinação de nitro-HPAs por GCxGC com o modulador empregado é possível se for feita através do método de padronização interna. O sistema GCxGC empregado causou dificuldades operacionais, principalmente na conexão das colunas e na modulação. Perdas de massa de analito foram detectadas nas análises por GCxGC, muito provavelmente causadas por uma conexão parcial das colunas. Isso poderia ser evitado se a conexão fosse feita pela fusão das colunas a um conector de vidro adequado a essa finalidade. Picos modulados divididos foram observados com frequência, o que comprometeu a precisão e exatidão dos resultados. A divisão dos picos ocorreu de modo aleatório dificultando a identificação da causa mais provável para a sua ocorrência. Cromatogramas GCxGC de extratos orgânicos não fracionados de particulados no ar, oriundos de queima direta de palha de cana-de-açúcar, de região afetada pela queima de cana-de-açúcar e de área urbana da cidade de São Paulo, mostraram a potencialidade do método
id USP_595a351933f795741b6807411dc77cee
oai_identifier_str oai:teses.usp.br:tde-05082013-155917
network_acronym_str USP
network_name_str Biblioteca Digital de Teses e Dissertações da USP
repository_id_str
spelling info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesis Contribuições para o desenvolvimento de método por GCxGC para a análise de nitro-HPAs em material particulado no ar Contributions to the GCxGC method development for the analysis of nitro-PAHs in airborne particulate material 2013-05-20Lilian Rothschild Franco de CarvalhoFabio AugustoClaudimir Lucio do LagoBruno Spinosa de MartinisJorge Cesar MasiniSilvana Odete PisaniUniversidade de São PauloQuímicaUSPBR Atmosphere particulate material Chromatography CO2 dual jet cryogenic modulator Comprehensive two-dimensional gas chromatography Cromatografia Cromatografia gasosa bidimensional abrangente Dual Jet Material particulado no ar Modulador criogênico de dois jatos de CO2 líquido Nitro-HPAs Nitro-PAHs PTV-GCxGC-FID PTVGCxGC- FID Os hidrocarbonetos policíclicos aromáticos nitrados (nitro-HPAs) são potencialmente genotóxicos, por isso existe um grande interesse na determinação analítica desses compostos no material particulado no ar. Os nitro-PAHs são emitidos diretamente para a atmosfera pela combustão incompleta ou podem ser formados in situ a partir dos HPAs precursores. Neste trabalho, são apresentados os resultados obtidos no desenvolvimento de um método de análise de nitro-HPAs (1-nitronaftaleno, 2-nitronaftaleno, 1-nitropireno, 2-nitropireno, 2-nitrofluoranteno, 3-nitrofluoranteno, 1,3-dinitropireno, 1,6- dinitropireno, 2-nitrofluoreno, 6-nitrocriseno, 7-nitrobenzo(a)antraceno, 9- nitroantraceno e 9-nitrofenantreno) por GCxGC. A separação destes compostos por GCxGC pode simplificar a etapa de pré-tratamento do extrato orgânico oriundo do material particulado no ar. A GCxGC promove a separação em duas colunas com mecanismos de separação diferentes, conectadas em série, o que resulta em uma capacidade de separação maior. O sistema GCxGC empregado neste trabalho possui um injetor com programação de temperatura (PTV), um modulador criogênico de dois jatos de CO2 líquido (Dual Jet) e um detector por ionização em chama (FID). A separação foi feita empregando a fase estacionária apolar 5% fenil polisilfenilene siloxano na primeira coluna (30 m / 0,25 mm / 0,25 µm) e a semipolar 14% cianopropilfenil polisiloxano na segunda coluna (1 m / 0,10 mm / 0,10 µm). Diferentes condições cromatográficas foram testadas, como: programação de temperatura no PTV, de 40-90ºC até 350ºC, com taxa de aquecimento de 2,2 e 14,5ºC/s; programação de temperatura no forno, de 40-90ºC até 300ºC, com taxa de aquecimento de 2, 2,5 e 3ºC/min; períodos de modulação de 3, 4 e 5s. O volume injetado foi 2µL, no modo splitless; a vazão do gás de arraste (He) foi constante e igual a 1 mL/min e o detector FID foi operado em 120 Hz. As larguras de pico medidas em 10% da altura variaram de 167 a 350ms para 1- nitronaftaleno e 6-nitrocriseno, respectivamente, e a capacidade de pico para o conjunto de colunas de separação usado foi estimada em cerca de 9800. Parâmetros de validação, tais como os limites de detecção (200 a 500 ng/mL) e de quantificação (650 a 1600 ng/mL) para alguns nitro-HPAs foram determinados. Para a quantificação, foram testados os métodos por padronização interna e externa, sendo que, através dos resultados deste trabalho, pode-se mostrar que a determinação de nitro-HPAs por GCxGC com o modulador empregado é possível se for feita através do método de padronização interna. O sistema GCxGC empregado causou dificuldades operacionais, principalmente na conexão das colunas e na modulação. Perdas de massa de analito foram detectadas nas análises por GCxGC, muito provavelmente causadas por uma conexão parcial das colunas. Isso poderia ser evitado se a conexão fosse feita pela fusão das colunas a um conector de vidro adequado a essa finalidade. Picos modulados divididos foram observados com frequência, o que comprometeu a precisão e exatidão dos resultados. A divisão dos picos ocorreu de modo aleatório dificultando a identificação da causa mais provável para a sua ocorrência. Cromatogramas GCxGC de extratos orgânicos não fracionados de particulados no ar, oriundos de queima direta de palha de cana-de-açúcar, de região afetada pela queima de cana-de-açúcar e de área urbana da cidade de São Paulo, mostraram a potencialidade do método Nitro-polycyclic aromatic hydrocarbons (nitro-PAHs) are potentially genotoxic, so there is a great interest in the analytical determination of these compounds in airborne particulate matter. The nitro-PAHs are emitted directly into the atmosphere by incomplete combustion or may be formed in situ from PAHs. In this work, results obtained from the development of an analytical method for nitro-PAHs by GCxGC are presented. The nitro-PAHs studied were: 1- nitronaphthalene, 2-nitronaphthalene, 1-nitropyrene, 2-nitropyrene, 2- nitrofluoranthene, 3-nitrofluoranthene, 1,3-dinitropyrene, 1,6-dinitropyrene, 2- nitrofluorene, 6-nitrochrysene, 7-nitrobenzo(a)anthracene, 9-nitroanthracene and 9- nitrophenanthrene. The separation of these compounds by GCxGC should simplify the pretreatment step of the airborne particulate organic extract. In GCxGC two capillary columns of different mechanisms of separation are coupled by an interface called modulator, which increase significantly the chromatographic resolution. The GCxGC system used in this work is equipped with a PTV injector, a dual-stage double jets CO2 cryogenic modulator and a flame ionization detector (FID). The separation was carried out using a nonpolar stationary phase 5% methyl phenyl polysiloxane in the first column (30 m / 0.25 mm / 0.25 µm) and a semipolar 14% cyanopropyl phenyl dimethyl polysiloxane in the second column. Different chromatographic conditions were tested: the PTV was programmed from 40-90ºC to 350ºC at 2.2 and 14.5ºC/s; the oven was programmed from 40-90ºC to 350ºC at 2.0, 2.5 and 3.0ºC/min; the modulation periods tested were 3, 4 and 5s. The injected volume was 2µL in splitless mode, the carrier gas (He) flow rate of 1 mL/min was constant and the FID detector was operated at 120 Hz. Validation parameters, such as the limit of detection (200 - 500 ng/mL) and quantitation (650 - 1600 ng/mL) were determined. For quantification, the internal and external standardization methods were tested, and through the results of this study, it can be shown that the determination of nitro-PAHs by GCxGC with the modulator used is possible if made by internal standardization method. The GCxGC system presented operational difficulties, particularly in the column connection and in the modulation zone. A partial connection of the columns resulted in mass loss of the analytes. The connection of the columns could be more effective if it was made by fusing the columns to a glass connector suitable for this purpose. Divided modulated peaks were frequently observed, which compromised the precision and accuracy of the results. The division of the peaks occurred randomly hindering the identification of the most likely cause for its occurrence. GCxGC chromatograms corresponding to unfractionated organic extracts of airborne particulate material from the sugarcane straw burning, from an area impacted by sugar cane burning emissions and from an urban area of São Paulo City showed the capability of the method. https://doi.org/10.11606/T.46.2013.tde-05082013-155917info:eu-repo/semantics/openAccessporreponame:Biblioteca Digital de Teses e Dissertações da USPinstname:Universidade de São Paulo (USP)instacron:USP2023-12-21T18:16:22Zoai:teses.usp.br:tde-05082013-155917Biblioteca Digital de Teses e Dissertaçõeshttp://www.teses.usp.br/PUBhttp://www.teses.usp.br/cgi-bin/mtd2br.plvirginia@if.usp.br|| atendimento@aguia.usp.br||virginia@if.usp.bropendoar:27212016-07-28T16:10:36Biblioteca Digital de Teses e Dissertações da USP - Universidade de São Paulo (USP)false
dc.title.pt.fl_str_mv Contribuições para o desenvolvimento de método por GCxGC para a análise de nitro-HPAs em material particulado no ar
dc.title.alternative.en.fl_str_mv Contributions to the GCxGC method development for the analysis of nitro-PAHs in airborne particulate material
title Contribuições para o desenvolvimento de método por GCxGC para a análise de nitro-HPAs em material particulado no ar
spellingShingle Contribuições para o desenvolvimento de método por GCxGC para a análise de nitro-HPAs em material particulado no ar
Silvana Odete Pisani
title_short Contribuições para o desenvolvimento de método por GCxGC para a análise de nitro-HPAs em material particulado no ar
title_full Contribuições para o desenvolvimento de método por GCxGC para a análise de nitro-HPAs em material particulado no ar
title_fullStr Contribuições para o desenvolvimento de método por GCxGC para a análise de nitro-HPAs em material particulado no ar
title_full_unstemmed Contribuições para o desenvolvimento de método por GCxGC para a análise de nitro-HPAs em material particulado no ar
title_sort Contribuições para o desenvolvimento de método por GCxGC para a análise de nitro-HPAs em material particulado no ar
author Silvana Odete Pisani
author_facet Silvana Odete Pisani
author_role author
dc.contributor.advisor1.fl_str_mv Lilian Rothschild Franco de Carvalho
dc.contributor.referee1.fl_str_mv Fabio Augusto
dc.contributor.referee2.fl_str_mv Claudimir Lucio do Lago
dc.contributor.referee3.fl_str_mv Bruno Spinosa de Martinis
dc.contributor.referee4.fl_str_mv Jorge Cesar Masini
dc.contributor.author.fl_str_mv Silvana Odete Pisani
contributor_str_mv Lilian Rothschild Franco de Carvalho
Fabio Augusto
Claudimir Lucio do Lago
Bruno Spinosa de Martinis
Jorge Cesar Masini
description Os hidrocarbonetos policíclicos aromáticos nitrados (nitro-HPAs) são potencialmente genotóxicos, por isso existe um grande interesse na determinação analítica desses compostos no material particulado no ar. Os nitro-PAHs são emitidos diretamente para a atmosfera pela combustão incompleta ou podem ser formados in situ a partir dos HPAs precursores. Neste trabalho, são apresentados os resultados obtidos no desenvolvimento de um método de análise de nitro-HPAs (1-nitronaftaleno, 2-nitronaftaleno, 1-nitropireno, 2-nitropireno, 2-nitrofluoranteno, 3-nitrofluoranteno, 1,3-dinitropireno, 1,6- dinitropireno, 2-nitrofluoreno, 6-nitrocriseno, 7-nitrobenzo(a)antraceno, 9- nitroantraceno e 9-nitrofenantreno) por GCxGC. A separação destes compostos por GCxGC pode simplificar a etapa de pré-tratamento do extrato orgânico oriundo do material particulado no ar. A GCxGC promove a separação em duas colunas com mecanismos de separação diferentes, conectadas em série, o que resulta em uma capacidade de separação maior. O sistema GCxGC empregado neste trabalho possui um injetor com programação de temperatura (PTV), um modulador criogênico de dois jatos de CO2 líquido (Dual Jet) e um detector por ionização em chama (FID). A separação foi feita empregando a fase estacionária apolar 5% fenil polisilfenilene siloxano na primeira coluna (30 m / 0,25 mm / 0,25 µm) e a semipolar 14% cianopropilfenil polisiloxano na segunda coluna (1 m / 0,10 mm / 0,10 µm). Diferentes condições cromatográficas foram testadas, como: programação de temperatura no PTV, de 40-90ºC até 350ºC, com taxa de aquecimento de 2,2 e 14,5ºC/s; programação de temperatura no forno, de 40-90ºC até 300ºC, com taxa de aquecimento de 2, 2,5 e 3ºC/min; períodos de modulação de 3, 4 e 5s. O volume injetado foi 2µL, no modo splitless; a vazão do gás de arraste (He) foi constante e igual a 1 mL/min e o detector FID foi operado em 120 Hz. As larguras de pico medidas em 10% da altura variaram de 167 a 350ms para 1- nitronaftaleno e 6-nitrocriseno, respectivamente, e a capacidade de pico para o conjunto de colunas de separação usado foi estimada em cerca de 9800. Parâmetros de validação, tais como os limites de detecção (200 a 500 ng/mL) e de quantificação (650 a 1600 ng/mL) para alguns nitro-HPAs foram determinados. Para a quantificação, foram testados os métodos por padronização interna e externa, sendo que, através dos resultados deste trabalho, pode-se mostrar que a determinação de nitro-HPAs por GCxGC com o modulador empregado é possível se for feita através do método de padronização interna. O sistema GCxGC empregado causou dificuldades operacionais, principalmente na conexão das colunas e na modulação. Perdas de massa de analito foram detectadas nas análises por GCxGC, muito provavelmente causadas por uma conexão parcial das colunas. Isso poderia ser evitado se a conexão fosse feita pela fusão das colunas a um conector de vidro adequado a essa finalidade. Picos modulados divididos foram observados com frequência, o que comprometeu a precisão e exatidão dos resultados. A divisão dos picos ocorreu de modo aleatório dificultando a identificação da causa mais provável para a sua ocorrência. Cromatogramas GCxGC de extratos orgânicos não fracionados de particulados no ar, oriundos de queima direta de palha de cana-de-açúcar, de região afetada pela queima de cana-de-açúcar e de área urbana da cidade de São Paulo, mostraram a potencialidade do método
publishDate 2013
dc.date.issued.fl_str_mv 2013-05-20
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://doi.org/10.11606/T.46.2013.tde-05082013-155917
url https://doi.org/10.11606/T.46.2013.tde-05082013-155917
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv Universidade de São Paulo
dc.publisher.program.fl_str_mv Química
dc.publisher.initials.fl_str_mv USP
dc.publisher.country.fl_str_mv BR
publisher.none.fl_str_mv Universidade de São Paulo
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações da USP
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Biblioteca Digital de Teses e Dissertações da USP
collection Biblioteca Digital de Teses e Dissertações da USP
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da USP - Universidade de São Paulo (USP)
repository.mail.fl_str_mv virginia@if.usp.br|| atendimento@aguia.usp.br||virginia@if.usp.br
_version_ 1786376581904596992