Comparação da bioimpedância frente ao padrão ouro para composição corporal em idosas
Ano de defesa: | 2018 |
---|---|
Autor(a) principal: | |
Orientador(a): | |
Banca de defesa: | |
Tipo de documento: | Dissertação |
Tipo de acesso: | Acesso aberto |
Idioma: | por |
Instituição de defesa: |
Universidade Católica de Brasília
|
Programa de Pós-Graduação: |
Programa Stricto Sensu em Gerontologia
|
Departamento: |
Escola de Saúde e Medicina
|
País: |
Brasil
|
Palavras-chave em Português: | |
Palavras-chave em Inglês: | |
Área do conhecimento CNPq: | |
Resumo em Inglês: | Objective: to compare distinct bioimpedances (BIAs) in front of the gold standard for body composition in elderly women, verifying the existence of a correlation between the methods and the necessity or not of using a previous protocol of hydration. Methods: a cross-sectional, descriptive and comparative study with 83 elderly women aged 60 years or older attending the Center for the Cohabitation of the Elderly at the Catholic University of Brasília. In order to determine the body composition, we used x - ray Absorptiometry (DXA), InBody 120 and Biodynamics 310e, with and without hydration protocol. Results: Bioimpedance only showed no difference with and without protocol (p = 0.70). Among the age groups there was no difference in fat percentage (p = 0.44) and fat free lean mass (p = 0.22). In the total sample, Bioimpedances underestimate the percentage of body fat and underestimate lean fat free mass compared to DXA. According to nutritional status by the InBody 120, the percentage of fat in the elderly women with low weight, eutrophic and obese were equal to the DXA and fat-free lean mass in obese women. Conclusion: BIA is an instrument capable of measuring body composition in elderly women in front of DXA, but it is necessary to verify the accuracy of the equipment, since both the measurement of the body composition and the performance or not of the hydration protocol will exist differences in the results, independent of the hydration protocol or not. |
Link de acesso: | https://bdtd.ucb.br:8443/jspui/handle/tede/2461 |
Resumo: | Objective: to compare distinct bioimpedances (BIAs) in front of the gold standard for body composition in elderly women, verifying the existence of a correlation between the methods and the necessity or not of using a previous protocol of hydration. Methods: a cross-sectional, descriptive and comparative study with 83 elderly women aged 60 years or older attending the Center for the Cohabitation of the Elderly at the Catholic University of Brasília. In order to determine the body composition, we used x - ray Absorptiometry (DXA), InBody 120 and Biodynamics 310e, with and without hydration protocol. Results: Bioimpedance only showed no difference with and without protocol (p = 0.70). Among the age groups there was no difference in fat percentage (p = 0.44) and fat free lean mass (p = 0.22). In the total sample, Bioimpedances underestimate the percentage of body fat and underestimate lean fat free mass compared to DXA. According to nutritional status by the InBody 120, the percentage of fat in the elderly women with low weight, eutrophic and obese were equal to the DXA and fat-free lean mass in obese women. Conclusion: BIA is an instrument capable of measuring body composition in elderly women in front of DXA, but it is necessary to verify the accuracy of the equipment, since both the measurement of the body composition and the performance or not of the hydration protocol will exist differences in the results, independent of the hydration protocol or not. |
id |
UCB_ca44326eaa1af1e83e80f88f23e82fc1 |
---|---|
oai_identifier_str |
oai:bdtd.ucb.br:tede/2461 |
network_acronym_str |
UCB |
network_name_str |
Biblioteca Digital de Teses e Dissertações da UCB |
spelling |
Carvalho, Gustavo de Azevedohttp://lattes.cnpq.br/7711160989704684http://lattes.cnpq.br/8649753943637718Ayub, Pollyanna2018-09-17T13:44:34Z2018-06-26AYUB, Pollyanna. Comparação da bioimpedância frente ao padrão ouro para composição corporal em idosas. 2018. 84 f. Dissertação (Programa Stricto Sensu em Gerontologia) - Universidade Católica de Brasília, Brasília, 2018.https://bdtd.ucb.br:8443/jspui/handle/tede/2461Objective: to compare distinct bioimpedances (BIAs) in front of the gold standard for body composition in elderly women, verifying the existence of a correlation between the methods and the necessity or not of using a previous protocol of hydration. Methods: a cross-sectional, descriptive and comparative study with 83 elderly women aged 60 years or older attending the Center for the Cohabitation of the Elderly at the Catholic University of Brasília. In order to determine the body composition, we used x - ray Absorptiometry (DXA), InBody 120 and Biodynamics 310e, with and without hydration protocol. Results: Bioimpedance only showed no difference with and without protocol (p = 0.70). Among the age groups there was no difference in fat percentage (p = 0.44) and fat free lean mass (p = 0.22). In the total sample, Bioimpedances underestimate the percentage of body fat and underestimate lean fat free mass compared to DXA. According to nutritional status by the InBody 120, the percentage of fat in the elderly women with low weight, eutrophic and obese were equal to the DXA and fat-free lean mass in obese women. Conclusion: BIA is an instrument capable of measuring body composition in elderly women in front of DXA, but it is necessary to verify the accuracy of the equipment, since both the measurement of the body composition and the performance or not of the hydration protocol will exist differences in the results, independent of the hydration protocol or not.Objetivo: Determinar o nível de concordância entre dois equipamentos de bioimpedâncias elétricas frente ao padrão-ouro Absorciometria por dupla emissão de Raios – x (DXA), na avaliação da composição corporal em idosas; conferir, pelo método DXA, se existe alteração na composição corporal por faixa etária – 60 a 64, 65 a 69 e 70 anos ou mais e verificar se existe diferença, utilizando-se o método de bioimpedância, na Porcentagem de Gordura Corporal (%GC), Massa Magra Livre de Gordura (MMLG) e Taxa de Metabolismo Basal (TBM), quando o protocolo de hidratação é realizado ou não. Métodos: estudo transversal, descritivo e comparativo com 83 idosas de 60 anos ou mais que frequentam o Centro de Convivência do Idoso da Universidade Católica de Brasília. Para determinar a avaliação da composição corporal utilizou-se os equipamentos (DXA), InBody 120 e Biodynamics 310e, com e sem protocolo de hidratação. Resultados: apenas na BIA 120 não houve diferença com e sem protocolo (p=0,70). Entre as faixas etárias não houve diferença na porcentagem de gordura (p=0,44) e massa magra livre de gordura (p= 0,22). Na amostra total, as Bioimpedâncias subestimam a porcentagem de gordura corporal e subestimam massa magra livre de gordura em comparação à DXA. De acordo com estado nutricional pelo IMC a InBody 120, o percentual de gordura nas idosas com baixo peso, eutróficas e obesas foram iguais à DXA e a massa magra livre de gordura em obesas. Conclusão: a BIA é um equipamento apto a mensurar a composição corporal em idosas em frente à DXA, porém é necessário verificar a precisão do equipamento, pois tanto na mensuração da composição corporal quanto na realização ou não do protocolo de hidratação existirão diferenças nos resultados, independente do protocolo de hidratação ou não.Submitted by Sara Ribeiro (sara.ribeiro@ucb.br) on 2018-09-17T13:44:16Z No. of bitstreams: 1 PollyannaAyubDissertacao2018.pdf: 1758469 bytes, checksum: d2688a9966cb1580d8d1dc969b3bccfa (MD5)Approved for entry into archive by Sara Ribeiro (sara.ribeiro@ucb.br) on 2018-09-17T13:44:34Z (GMT) No. of bitstreams: 1 PollyannaAyubDissertacao2018.pdf: 1758469 bytes, checksum: d2688a9966cb1580d8d1dc969b3bccfa (MD5)Made available in DSpace on 2018-09-17T13:44:34Z (GMT). No. of bitstreams: 1 PollyannaAyubDissertacao2018.pdf: 1758469 bytes, checksum: d2688a9966cb1580d8d1dc969b3bccfa (MD5) Previous issue date: 2018-06-26application/pdfhttps://bdtd.ucb.br:8443/jspui/retrieve/5949/PollyannaAyubDissertacao2018.pdf.jpgporUniversidade Católica de BrasíliaPrograma Stricto Sensu em GerontologiaUCBBrasilEscola de Saúde e MedicinaIdosasGerontologiaComposição corporalBioimpedância elétricaElectrical impedanceBody compositionGerontologyElderlyCNPQ::CIENCIAS DA SAUDEComparação da bioimpedância frente ao padrão ouro para composição corporal em idosasinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisinfo:eu-repo/semantics/openAccessreponame:Biblioteca Digital de Teses e Dissertações da UCBinstname:Universidade Católica de Brasíliainstacron:UCBTHUMBNAILPollyannaAyubDissertacao2018.pdf.jpgPollyannaAyubDissertacao2018.pdf.jpgimage/jpeg5226https://bdtd.ucb.br:8443/jspui/bitstream/tede/2461/4/PollyannaAyubDissertacao2018.pdf.jpgf656357f9e1cc55b61f6b815e72d4445MD54TEXTPollyannaAyubDissertacao2018.pdf.txtPollyannaAyubDissertacao2018.pdf.txttext/plain167134https://bdtd.ucb.br:8443/jspui/bitstream/tede/2461/3/PollyannaAyubDissertacao2018.pdf.txt8909f118ca0edbd2cb023f5fb839cc31MD53ORIGINALPollyannaAyubDissertacao2018.pdfPollyannaAyubDissertacao2018.pdfapplication/pdf1758469https://bdtd.ucb.br:8443/jspui/bitstream/tede/2461/2/PollyannaAyubDissertacao2018.pdfd2688a9966cb1580d8d1dc969b3bccfaMD52LICENSElicense.txtlicense.txttext/plain; charset=utf-81831https://bdtd.ucb.br:8443/jspui/bitstream/tede/2461/1/license.txtd7d5e5ec75089f122abe937645a56120MD51tede/2461oai:bdtd.ucb.br:tede/24612018-09-18 01:09:11.957Biblioteca Digital de Dissertações da Universidade Católica de Brasília - UCBsdi@ucb.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 |
dc.title.por.fl_str_mv |
Comparação da bioimpedância frente ao padrão ouro para composição corporal em idosas |
title |
Comparação da bioimpedância frente ao padrão ouro para composição corporal em idosas |
spellingShingle |
Comparação da bioimpedância frente ao padrão ouro para composição corporal em idosas Ayub, Pollyanna Idosas Gerontologia Composição corporal Bioimpedância elétrica Electrical impedance Body composition Gerontology Elderly CNPQ::CIENCIAS DA SAUDE |
title_short |
Comparação da bioimpedância frente ao padrão ouro para composição corporal em idosas |
title_full |
Comparação da bioimpedância frente ao padrão ouro para composição corporal em idosas |
title_fullStr |
Comparação da bioimpedância frente ao padrão ouro para composição corporal em idosas |
title_full_unstemmed |
Comparação da bioimpedância frente ao padrão ouro para composição corporal em idosas |
title_sort |
Comparação da bioimpedância frente ao padrão ouro para composição corporal em idosas |
author |
Ayub, Pollyanna |
author_facet |
Ayub, Pollyanna |
author_role |
author |
dc.contributor.advisor1.fl_str_mv |
Carvalho, Gustavo de Azevedo |
dc.contributor.advisor1Lattes.fl_str_mv |
http://lattes.cnpq.br/7711160989704684 |
dc.contributor.authorLattes.fl_str_mv |
http://lattes.cnpq.br/8649753943637718 |
dc.contributor.author.fl_str_mv |
Ayub, Pollyanna |
contributor_str_mv |
Carvalho, Gustavo de Azevedo |
dc.subject.por.fl_str_mv |
Idosas Gerontologia Composição corporal Bioimpedância elétrica |
topic |
Idosas Gerontologia Composição corporal Bioimpedância elétrica Electrical impedance Body composition Gerontology Elderly CNPQ::CIENCIAS DA SAUDE |
dc.subject.eng.fl_str_mv |
Electrical impedance Body composition Gerontology Elderly |
dc.subject.cnpq.fl_str_mv |
CNPQ::CIENCIAS DA SAUDE |
dc.description.abstract.eng.fl_txt_mv |
Objective: to compare distinct bioimpedances (BIAs) in front of the gold standard for body composition in elderly women, verifying the existence of a correlation between the methods and the necessity or not of using a previous protocol of hydration. Methods: a cross-sectional, descriptive and comparative study with 83 elderly women aged 60 years or older attending the Center for the Cohabitation of the Elderly at the Catholic University of Brasília. In order to determine the body composition, we used x - ray Absorptiometry (DXA), InBody 120 and Biodynamics 310e, with and without hydration protocol. Results: Bioimpedance only showed no difference with and without protocol (p = 0.70). Among the age groups there was no difference in fat percentage (p = 0.44) and fat free lean mass (p = 0.22). In the total sample, Bioimpedances underestimate the percentage of body fat and underestimate lean fat free mass compared to DXA. According to nutritional status by the InBody 120, the percentage of fat in the elderly women with low weight, eutrophic and obese were equal to the DXA and fat-free lean mass in obese women. Conclusion: BIA is an instrument capable of measuring body composition in elderly women in front of DXA, but it is necessary to verify the accuracy of the equipment, since both the measurement of the body composition and the performance or not of the hydration protocol will exist differences in the results, independent of the hydration protocol or not. |
dc.description.abstract.por.fl_txt_mv |
Objetivo: Determinar o nível de concordância entre dois equipamentos de bioimpedâncias elétricas frente ao padrão-ouro Absorciometria por dupla emissão de Raios – x (DXA), na avaliação da composição corporal em idosas; conferir, pelo método DXA, se existe alteração na composição corporal por faixa etária – 60 a 64, 65 a 69 e 70 anos ou mais e verificar se existe diferença, utilizando-se o método de bioimpedância, na Porcentagem de Gordura Corporal (%GC), Massa Magra Livre de Gordura (MMLG) e Taxa de Metabolismo Basal (TBM), quando o protocolo de hidratação é realizado ou não. Métodos: estudo transversal, descritivo e comparativo com 83 idosas de 60 anos ou mais que frequentam o Centro de Convivência do Idoso da Universidade Católica de Brasília. Para determinar a avaliação da composição corporal utilizou-se os equipamentos (DXA), InBody 120 e Biodynamics 310e, com e sem protocolo de hidratação. Resultados: apenas na BIA 120 não houve diferença com e sem protocolo (p=0,70). Entre as faixas etárias não houve diferença na porcentagem de gordura (p=0,44) e massa magra livre de gordura (p= 0,22). Na amostra total, as Bioimpedâncias subestimam a porcentagem de gordura corporal e subestimam massa magra livre de gordura em comparação à DXA. De acordo com estado nutricional pelo IMC a InBody 120, o percentual de gordura nas idosas com baixo peso, eutróficas e obesas foram iguais à DXA e a massa magra livre de gordura em obesas. Conclusão: a BIA é um equipamento apto a mensurar a composição corporal em idosas em frente à DXA, porém é necessário verificar a precisão do equipamento, pois tanto na mensuração da composição corporal quanto na realização ou não do protocolo de hidratação existirão diferenças nos resultados, independente do protocolo de hidratação ou não. |
description |
Objective: to compare distinct bioimpedances (BIAs) in front of the gold standard for body composition in elderly women, verifying the existence of a correlation between the methods and the necessity or not of using a previous protocol of hydration. Methods: a cross-sectional, descriptive and comparative study with 83 elderly women aged 60 years or older attending the Center for the Cohabitation of the Elderly at the Catholic University of Brasília. In order to determine the body composition, we used x - ray Absorptiometry (DXA), InBody 120 and Biodynamics 310e, with and without hydration protocol. Results: Bioimpedance only showed no difference with and without protocol (p = 0.70). Among the age groups there was no difference in fat percentage (p = 0.44) and fat free lean mass (p = 0.22). In the total sample, Bioimpedances underestimate the percentage of body fat and underestimate lean fat free mass compared to DXA. According to nutritional status by the InBody 120, the percentage of fat in the elderly women with low weight, eutrophic and obese were equal to the DXA and fat-free lean mass in obese women. Conclusion: BIA is an instrument capable of measuring body composition in elderly women in front of DXA, but it is necessary to verify the accuracy of the equipment, since both the measurement of the body composition and the performance or not of the hydration protocol will exist differences in the results, independent of the hydration protocol or not. |
publishDate |
2018 |
dc.date.accessioned.fl_str_mv |
2018-09-17T13:44:34Z |
dc.date.issued.fl_str_mv |
2018-06-26 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
status_str |
publishedVersion |
format |
masterThesis |
dc.identifier.citation.fl_str_mv |
AYUB, Pollyanna. Comparação da bioimpedância frente ao padrão ouro para composição corporal em idosas. 2018. 84 f. Dissertação (Programa Stricto Sensu em Gerontologia) - Universidade Católica de Brasília, Brasília, 2018. |
dc.identifier.uri.fl_str_mv |
https://bdtd.ucb.br:8443/jspui/handle/tede/2461 |
identifier_str_mv |
AYUB, Pollyanna. Comparação da bioimpedância frente ao padrão ouro para composição corporal em idosas. 2018. 84 f. Dissertação (Programa Stricto Sensu em Gerontologia) - Universidade Católica de Brasília, Brasília, 2018. |
url |
https://bdtd.ucb.br:8443/jspui/handle/tede/2461 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade Católica de Brasília |
dc.publisher.program.fl_str_mv |
Programa Stricto Sensu em Gerontologia |
dc.publisher.initials.fl_str_mv |
UCB |
dc.publisher.country.fl_str_mv |
Brasil |
dc.publisher.department.fl_str_mv |
Escola de Saúde e Medicina |
publisher.none.fl_str_mv |
Universidade Católica de Brasília |
dc.source.none.fl_str_mv |
reponame:Biblioteca Digital de Teses e Dissertações da UCB instname:Universidade Católica de Brasília instacron:UCB |
reponame_str |
Biblioteca Digital de Teses e Dissertações da UCB |
collection |
Biblioteca Digital de Teses e Dissertações da UCB |
instname_str |
Universidade Católica de Brasília |
instacron_str |
UCB |
institution |
UCB |
bitstream.url.fl_str_mv |
https://bdtd.ucb.br:8443/jspui/bitstream/tede/2461/4/PollyannaAyubDissertacao2018.pdf.jpg https://bdtd.ucb.br:8443/jspui/bitstream/tede/2461/3/PollyannaAyubDissertacao2018.pdf.txt https://bdtd.ucb.br:8443/jspui/bitstream/tede/2461/2/PollyannaAyubDissertacao2018.pdf https://bdtd.ucb.br:8443/jspui/bitstream/tede/2461/1/license.txt |
bitstream.checksum.fl_str_mv |
f656357f9e1cc55b61f6b815e72d4445 8909f118ca0edbd2cb023f5fb839cc31 d2688a9966cb1580d8d1dc969b3bccfa d7d5e5ec75089f122abe937645a56120 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 MD5 |
repository.name.fl_str_mv |
Biblioteca Digital de Dissertações da Universidade Católica de Brasília - UCB |
repository.mail.fl_str_mv |
sdi@ucb.br |
_version_ |
1643299889736581120 |