Avaliação "in vitro" da microinfiltração em dentes restaurados com resinas, por imagens radiográficas
Ano de defesa: | 2013 |
---|---|
Autor(a) principal: | |
Orientador(a): | |
Banca de defesa: | |
Tipo de documento: | Tese |
Tipo de acesso: | Acesso aberto |
Idioma: | por |
Instituição de defesa: |
Não Informado pela instituição
|
Programa de Pós-Graduação: |
Não Informado pela instituição
|
Departamento: |
Não Informado pela instituição
|
País: |
Não Informado pela instituição
|
Resumo em Inglês: | Neutrongraphic inspections of microleakage in restored teeth will provide to dentists, informations regarding about adhesion of polymeric synthetic resins to tooth cavity after the complete restorative process. So, was subjected to intervention with dental rotary drill samples to produce them cavities of similar dimensions, which have been carefully filled with different synthetic resins in order to avoid the occurrence of voids. We used eight types of resins, among the most commercialized in Rio de Janeiro. The restored teeth were radiographed and neutrographed and their images analyzed. By the neutrographic mages obtained, it was concluded that there was good grip in all resins used, not being viewed microleakage, as was expected, a painstaking restoration procedure. It was necessary to simulate defects such as: no adhesives or acid cleaning during the restorations. Using the system, with a maximum resolution of about 56 microns microleakage could be visualized through neutrongraphic images and the Neutrongraphy performance was superior to conventional radiographic technique |
Link de acesso: | http://hdl.handle.net/ien/811 |
Resumo: | Inspeções neutrongráficas de microinfiltrações em dentes restaurados fornecerão aos odontólogos, informações quanto a aderência de resinas poliméricas sintéticas à cavidade dentária, após o completo processo restaurativo. Para tal, submeteu-se amostras dentárias à intervenção com broca rotativa, produzindo nelas cavidades de dimensões similares, que foram cuidadosamente preenchidas com diferentes resinas sintéticas de forma a se evitar a ocorrência de vazios. Empregou-se oito tipos de resinas, dentre as mais comercializadas no Rio de Janeiro. Os dentes restaurados foram neutrongrafados e radiografados e suas imagens analisadas. Pelas imagens neutrongráficas obtidas, concluiu-se que houve uma boa aderência em todas as resinas empregadas, não sendo visualizadas microinfiltrações, como era de se esperar, num procedimento esmerado de restauração. Fez-se necessário a simulação de defeitos, como: ausência de adesivos ou limpeza ácida, durante as restaurações. Com o uso do sistema, cuja resolução máxima em torno de 56, microinfiltrações puderam ser visualizadas através das imagens neutrográficas o desempenho da Neutrongrafia mostrou-se superior ao da técnica radiográfica convencional. |
id |
IEN_f48ef85d1ea0baddf6323584624c72e6 |
---|---|
oai_identifier_str |
oai:carpedien.ien.gov.br:ien/811 |
network_acronym_str |
IEN |
network_name_str |
Repositório Institucional do IEN |
spelling |
BARBOSA, André Luis NunesSILVA, Ademir Xavier daBRANDÃO, Luis Eduardo BarreiraCARMO, Eduardo Gomes Dutra doROSA, Luiz Antonio Ribeiro daFERREIRA, Francisco José de OliveiraCRISPIM, Verginia Reis2014-08-08T17:29:28Z2014-08-08T17:29:28Z20132013-12Barbosa, André Luís Nunes. Avaliação "in vitro" da microinfiltração em dentes restaurados com resinas, por imagens radiográficas. Rio de Janeiro: UFRJ, 2013. 100p. Tese (Doutorado em Engenharia Nuclear)http://hdl.handle.net/ien/811Inspeções neutrongráficas de microinfiltrações em dentes restaurados fornecerão aos odontólogos, informações quanto a aderência de resinas poliméricas sintéticas à cavidade dentária, após o completo processo restaurativo. Para tal, submeteu-se amostras dentárias à intervenção com broca rotativa, produzindo nelas cavidades de dimensões similares, que foram cuidadosamente preenchidas com diferentes resinas sintéticas de forma a se evitar a ocorrência de vazios. Empregou-se oito tipos de resinas, dentre as mais comercializadas no Rio de Janeiro. Os dentes restaurados foram neutrongrafados e radiografados e suas imagens analisadas. Pelas imagens neutrongráficas obtidas, concluiu-se que houve uma boa aderência em todas as resinas empregadas, não sendo visualizadas microinfiltrações, como era de se esperar, num procedimento esmerado de restauração. Fez-se necessário a simulação de defeitos, como: ausência de adesivos ou limpeza ácida, durante as restaurações. Com o uso do sistema, cuja resolução máxima em torno de 56, microinfiltrações puderam ser visualizadas através das imagens neutrográficas o desempenho da Neutrongrafia mostrou-se superior ao da técnica radiográfica convencional.Neutrongraphic inspections of microleakage in restored teeth will provide to dentists, informations regarding about adhesion of polymeric synthetic resins to tooth cavity after the complete restorative process. So, was subjected to intervention with dental rotary drill samples to produce them cavities of similar dimensions, which have been carefully filled with different synthetic resins in order to avoid the occurrence of voids. We used eight types of resins, among the most commercialized in Rio de Janeiro. The restored teeth were radiographed and neutrographed and their images analyzed. By the neutrographic mages obtained, it was concluded that there was good grip in all resins used, not being viewed microleakage, as was expected, a painstaking restoration procedure. It was necessary to simulate defects such as: no adhesives or acid cleaning during the restorations. Using the system, with a maximum resolution of about 56 microns microleakage could be visualized through neutrongraphic images and the Neutrongraphy performance was superior to conventional radiographic techniqueSubmitted by Almir Azevedo (barbio1313@gmail.com) on 2014-08-08T17:29:28Z No. of bitstreams: 0Made available in DSpace on 2014-08-08T17:29:28Z (GMT). No. of bitstreams: 0 Previous issue date: 2013NeutrongrafiaResinasAvaliação "in vitro" da microinfiltração em dentes restaurados com resinas, por imagens radiográficasinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisRio de JaneiroUFRJCOPPEporreponame:Repositório Institucional do IENinstname:Instituto de Engenharia Nuclearinstacron:IENinfo:eu-repo/semantics/openAccessORIGINALAVALIAÇÃO “IN VITRO” .pdfAVALIAÇÃO “IN VITRO” .pdfapplication/pdf9740436http://carpedien.ien.gov.br:8080/xmlui/bitstream/ien/811/2/AVALIA%C3%87%C3%83O+%E2%80%9CIN+VITRO%E2%80%9D+.pdf14c96c256ebdbaa9d0cad0790117d60cMD52LICENSElicense.txtlicense.txttext/plain; charset=utf-81748http://carpedien.ien.gov.br:8080/xmlui/bitstream/ien/811/1/license.txt8a4605be74aa9ea9d79846c1fba20a33MD51ien/811oai:carpedien.ien.gov.br:ien/8112015-06-17 15:47:43.002Dspace IENlsales@ien.gov.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 |
dc.title.pt_BR.fl_str_mv |
Avaliação "in vitro" da microinfiltração em dentes restaurados com resinas, por imagens radiográficas |
title |
Avaliação "in vitro" da microinfiltração em dentes restaurados com resinas, por imagens radiográficas |
spellingShingle |
Avaliação "in vitro" da microinfiltração em dentes restaurados com resinas, por imagens radiográficas BARBOSA, André Luis Nunes Neutrongrafia Resinas |
title_short |
Avaliação "in vitro" da microinfiltração em dentes restaurados com resinas, por imagens radiográficas |
title_full |
Avaliação "in vitro" da microinfiltração em dentes restaurados com resinas, por imagens radiográficas |
title_fullStr |
Avaliação "in vitro" da microinfiltração em dentes restaurados com resinas, por imagens radiográficas |
title_full_unstemmed |
Avaliação "in vitro" da microinfiltração em dentes restaurados com resinas, por imagens radiográficas |
title_sort |
Avaliação "in vitro" da microinfiltração em dentes restaurados com resinas, por imagens radiográficas |
author |
BARBOSA, André Luis Nunes |
author_facet |
BARBOSA, André Luis Nunes |
author_role |
author |
dc.contributor.member.none.fl_str_mv |
SILVA, Ademir Xavier da BRANDÃO, Luis Eduardo Barreira CARMO, Eduardo Gomes Dutra do ROSA, Luiz Antonio Ribeiro da FERREIRA, Francisco José de Oliveira |
dc.contributor.author.fl_str_mv |
BARBOSA, André Luis Nunes |
dc.contributor.advisor1.fl_str_mv |
CRISPIM, Verginia Reis |
contributor_str_mv |
CRISPIM, Verginia Reis |
dc.subject.other.pt_BR.fl_str_mv |
Neutrongrafia Resinas |
topic |
Neutrongrafia Resinas |
dc.description.abstract.por.fl_txt_mv |
Inspeções neutrongráficas de microinfiltrações em dentes restaurados fornecerão aos odontólogos, informações quanto a aderência de resinas poliméricas sintéticas à cavidade dentária, após o completo processo restaurativo. Para tal, submeteu-se amostras dentárias à intervenção com broca rotativa, produzindo nelas cavidades de dimensões similares, que foram cuidadosamente preenchidas com diferentes resinas sintéticas de forma a se evitar a ocorrência de vazios. Empregou-se oito tipos de resinas, dentre as mais comercializadas no Rio de Janeiro. Os dentes restaurados foram neutrongrafados e radiografados e suas imagens analisadas. Pelas imagens neutrongráficas obtidas, concluiu-se que houve uma boa aderência em todas as resinas empregadas, não sendo visualizadas microinfiltrações, como era de se esperar, num procedimento esmerado de restauração. Fez-se necessário a simulação de defeitos, como: ausência de adesivos ou limpeza ácida, durante as restaurações. Com o uso do sistema, cuja resolução máxima em torno de 56, microinfiltrações puderam ser visualizadas através das imagens neutrográficas o desempenho da Neutrongrafia mostrou-se superior ao da técnica radiográfica convencional. |
dc.description.abstract.eng.fl_txt_mv |
Neutrongraphic inspections of microleakage in restored teeth will provide to dentists, informations regarding about adhesion of polymeric synthetic resins to tooth cavity after the complete restorative process. So, was subjected to intervention with dental rotary drill samples to produce them cavities of similar dimensions, which have been carefully filled with different synthetic resins in order to avoid the occurrence of voids. We used eight types of resins, among the most commercialized in Rio de Janeiro. The restored teeth were radiographed and neutrographed and their images analyzed. By the neutrographic mages obtained, it was concluded that there was good grip in all resins used, not being viewed microleakage, as was expected, a painstaking restoration procedure. It was necessary to simulate defects such as: no adhesives or acid cleaning during the restorations. Using the system, with a maximum resolution of about 56 microns microleakage could be visualized through neutrongraphic images and the Neutrongraphy performance was superior to conventional radiographic technique |
description |
Inspeções neutrongráficas de microinfiltrações em dentes restaurados fornecerão aos odontólogos, informações quanto a aderência de resinas poliméricas sintéticas à cavidade dentária, após o completo processo restaurativo. Para tal, submeteu-se amostras dentárias à intervenção com broca rotativa, produzindo nelas cavidades de dimensões similares, que foram cuidadosamente preenchidas com diferentes resinas sintéticas de forma a se evitar a ocorrência de vazios. Empregou-se oito tipos de resinas, dentre as mais comercializadas no Rio de Janeiro. Os dentes restaurados foram neutrongrafados e radiografados e suas imagens analisadas. Pelas imagens neutrongráficas obtidas, concluiu-se que houve uma boa aderência em todas as resinas empregadas, não sendo visualizadas microinfiltrações, como era de se esperar, num procedimento esmerado de restauração. Fez-se necessário a simulação de defeitos, como: ausência de adesivos ou limpeza ácida, durante as restaurações. Com o uso do sistema, cuja resolução máxima em torno de 56, microinfiltrações puderam ser visualizadas através das imagens neutrográficas o desempenho da Neutrongrafia mostrou-se superior ao da técnica radiográfica convencional. |
publishDate |
2013 |
dc.date.degree.none.fl_str_mv |
2013-12 |
dc.date.issued.fl_str_mv |
2013 |
dc.date.accessioned.fl_str_mv |
2014-08-08T17:29:28Z |
dc.date.available.fl_str_mv |
2014-08-08T17:29:28Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/doctoralThesis |
status_str |
publishedVersion |
format |
doctoralThesis |
dc.identifier.citation.fl_str_mv |
Barbosa, André Luís Nunes. Avaliação "in vitro" da microinfiltração em dentes restaurados com resinas, por imagens radiográficas. Rio de Janeiro: UFRJ, 2013. 100p. Tese (Doutorado em Engenharia Nuclear) |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/ien/811 |
identifier_str_mv |
Barbosa, André Luís Nunes. Avaliação "in vitro" da microinfiltração em dentes restaurados com resinas, por imagens radiográficas. Rio de Janeiro: UFRJ, 2013. 100p. Tese (Doutorado em Engenharia Nuclear) |
url |
http://hdl.handle.net/ien/811 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional do IEN instname:Instituto de Engenharia Nuclear instacron:IEN |
reponame_str |
Repositório Institucional do IEN |
collection |
Repositório Institucional do IEN |
instname_str |
Instituto de Engenharia Nuclear |
instacron_str |
IEN |
institution |
IEN |
bitstream.url.fl_str_mv |
http://carpedien.ien.gov.br:8080/xmlui/bitstream/ien/811/2/AVALIA%C3%87%C3%83O+%E2%80%9CIN+VITRO%E2%80%9D+.pdf http://carpedien.ien.gov.br:8080/xmlui/bitstream/ien/811/1/license.txt |
bitstream.checksum.fl_str_mv |
14c96c256ebdbaa9d0cad0790117d60c 8a4605be74aa9ea9d79846c1fba20a33 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 |
repository.name.fl_str_mv |
Dspace IEN |
repository.mail.fl_str_mv |
lsales@ien.gov.br |
_version_ |
1623394159678193664 |