Resumo: | The electroencephalogram (EEG) is a widely used test to support the diagnosis of neurological disorders. Among its applications, scalp EEG stands out, a non-invasive method widely used in the detection of epilepsy, performed by attaching electrodes to the surface of the scalp. In the field of machine learning, the identification of epileptic seizures is a recurring task, and for anomaly detection, two approaches are generally adopted: binary classification and unary classification. In this context, this work explores the application of unary classification (one-class classification) in EEG signals. Seven methods were analyzed: minimum Euclidean distance to the centroid, minimum kernel Euclidean distance to the centroid (KDEMC), minimum Mahalanobis distance to the centroid, PCA, kernel PCA (KPCA), one-class SVM and isolation forest. For this purpose, the public CHB-MIT Scalp EEG dataset was used, considering different hypotheses for extracting segments with seizure occurrence (ictal EEG) and without seizure occurrence (non-ictal EEG) to generate the training and test sets. Feature extraction was performed using the covariance vector, a fast and efficient method for the task in question. Furthermore, a comparative analysis was performed with literature studies that use the binary classification paradigm. Based on the analysis and discussion of the results, it was observed that among the unary classifiers evaluated, KDEMC and KPCA stand out, achieving maximum accuracy of 95.53% and 97.27%, sensitivity (recall) of 98.66% and 99.40%, and precision of 96.10% and 86.61%. The best unary classifiers achieve performances equivalent to the binary classifiers in the literature. |
| id |
UFC-7_91b432755554fa8a65321f2fa222104c |
|---|---|
| oai_identifier_str |
oai:repositorio.ufc.br:riufc/88425 |
| network_acronym_str |
UFC-7 |
| network_name_str |
Repositório Institucional da Universidade Federal do Ceará (UFC) |
| repository_id_str |
|
| spelling |
Leitão, Patrícia Tavareshttp://lattes.cnpq.br/365921413https://orcid.org/0000-0002-7002-1216http://lattes.cnpq.br/8902002461422112Barreto, Guilherme de Alencar2026-11-03T17:42:53Z2026-11-03T17:42:53Z2025LEITÃO, Patrícia Tavares. Comparação de técnicas de classificação unária para detecção de crises epilépticas em eletroencefalogramas. 2025. Dissertação (Mestrado em Engenharia de Teleinformática) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2025.http://repositorio.ufc.br/handle/riufc/88425The electroencephalogram (EEG) is a widely used test to support the diagnosis of neurological disorders. Among its applications, scalp EEG stands out, a non-invasive method widely used in the detection of epilepsy, performed by attaching electrodes to the surface of the scalp. In the field of machine learning, the identification of epileptic seizures is a recurring task, and for anomaly detection, two approaches are generally adopted: binary classification and unary classification. In this context, this work explores the application of unary classification (one-class classification) in EEG signals. Seven methods were analyzed: minimum Euclidean distance to the centroid, minimum kernel Euclidean distance to the centroid (KDEMC), minimum Mahalanobis distance to the centroid, PCA, kernel PCA (KPCA), one-class SVM and isolation forest. For this purpose, the public CHB-MIT Scalp EEG dataset was used, considering different hypotheses for extracting segments with seizure occurrence (ictal EEG) and without seizure occurrence (non-ictal EEG) to generate the training and test sets. Feature extraction was performed using the covariance vector, a fast and efficient method for the task in question. Furthermore, a comparative analysis was performed with literature studies that use the binary classification paradigm. Based on the analysis and discussion of the results, it was observed that among the unary classifiers evaluated, KDEMC and KPCA stand out, achieving maximum accuracy of 95.53% and 97.27%, sensitivity (recall) of 98.66% and 99.40%, and precision of 96.10% and 86.61%. The best unary classifiers achieve performances equivalent to the binary classifiers in the literature.O eletroencefalograma (EEG) é um exame amplamente utilizado no apoio ao diagnóstico de distúrbios neurológicos. Entre suas aplicações, destaca-se o EEG de escalpo, um método não invasivo bastante empregado na detecção da epilepsia, realizado por meio da fixação de eletrodos na superfície do couro cabeludo. Na área do aprendizado de máquina, a identificação de crises epilépticas é uma tarefa recorrente e, para a detecção de anomalias, geralmente são adotadas duas abordagens: a classificação binária e a classificação unária. Neste contexto, o presente trabalho explora a aplicação da classificação unária (one-class classification) em sinais de EEG. Foram analisados sete métodos: distância euclidiana mínima ao centroide, distância euclidiana kernel mínima ao centroide (KDEMC), distância Mahalanobis mínima ao centroide, PCA, kernel PCA (KPCA), one-class SVM e isolation forest. Para isso, utilizou-se o conjunto de dados público de CHB-MIT Scalp EEG, considerando diferentes hipóteses de extração de segmentos com ocorrência de crises (EEG ictal) e sem ocorrência de crises (EEG não-ictal), para a geração dos conjuntos de treino e teste. A extração de atributos foi realizada por meio do vetor de covariâncias, um método rápido e eficiente para a tarefa em questão. Além disso, realizou-se uma análise comparativa com trabalhos da literatura que utilizam o paradigma da classificação binária. A partir da análise e discussão dos resultados, observou-se que entre os classificadores unários avaliados, destacam-se o KDEMC e o KPCA que alcançam acurácia máxima de 95,53% e 97,27%, sensibilidade (recall) de 98,66% e 99,40%, e precisão de 96,10% e 86,61%. Os melhores classificadores unários alcançam desempenhos equivalentes aos classificadores binários na literatura.Este documento está disponível online com base na Portaria no 348, de 08 de dezembro de 2022, disponível em: https://biblioteca.ufc.br/wp-content/uploads/2022/12/portaria348-2022.pdf, que autoriza a digitalização e a disponibilização no Repositório Institucional (RI) da coleção retrospectiva de TCC, dissertações e teses da UFC, sem o termo de anuência prévia dos autores. Em caso de trabalhos com pedidos de patente e/ou de embargo, cabe, exclusivamente, ao autor(a) solicitar a restrição de acesso ou retirada de seu trabalho do RI, mediante apresentação de documento comprobatório à Direção do Sistema de Bibliotecas.Comparação de técnicas de classificação unária para detecção de crises epilépticas em eletroencefalogramasComparison of one-class classification techniques for epileptic seizure detection in electroencephalograms.info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisCrises EpilépticasEletroencefalograma (EEG)Detecção de anomaliasClassificação unáriaAprendizado do computadorEpilepsiaEpileptic SeizuresElectroencephalogram (EEG)Anomaly detectionOne-class classificationMachine learningEpilepsyCNPQ::ENGENHARIASinfo:eu-repo/semantics/openAccessporreponame:Repositório Institucional da Universidade Federal do Ceará (UFC)instname:Universidade Federal do Ceará (UFC)instacron:UFC2026-10-01ORIGINAL2025_dis_ptleitao2025_dis_ptleitaoDissertaçãoapplication/pdf3273222http://repositorio.ufc.br/bitstream/riufc/88425/3/2025_dis_ptleitao545181b2f2602cc4ce86211434abe350MD53LICENSElicense.txtlicense.txttext/plain; charset=utf-81748http://repositorio.ufc.br/bitstream/riufc/88425/4/license.txt8a4605be74aa9ea9d79846c1fba20a33MD54riufc/884252026-11-11 09:01:58.239oai:repositorio.ufc.br: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Repositório InstitucionalPUBhttp://www.repositorio.ufc.br/ri-oai/requestbu@ufc.br || repositorio@ufc.bropendoar:2026-11-11T12:01:58Repositório Institucional da Universidade Federal do Ceará (UFC) - Universidade Federal do Ceará (UFC)false |
| dc.title.pt_BR.fl_str_mv |
Comparação de técnicas de classificação unária para detecção de crises epilépticas em eletroencefalogramas |
| dc.title.en.pt_BR.fl_str_mv |
Comparison of one-class classification techniques for epileptic seizure detection in electroencephalograms. |
| title |
Comparação de técnicas de classificação unária para detecção de crises epilépticas em eletroencefalogramas |
| spellingShingle |
Comparação de técnicas de classificação unária para detecção de crises epilépticas em eletroencefalogramas Leitão, Patrícia Tavares CNPQ::ENGENHARIAS Crises Epilépticas Eletroencefalograma (EEG) Detecção de anomalias Classificação unária Aprendizado do computador Epilepsia Epileptic Seizures Electroencephalogram (EEG) Anomaly detection One-class classification Machine learning Epilepsy |
| title_short |
Comparação de técnicas de classificação unária para detecção de crises epilépticas em eletroencefalogramas |
| title_full |
Comparação de técnicas de classificação unária para detecção de crises epilépticas em eletroencefalogramas |
| title_fullStr |
Comparação de técnicas de classificação unária para detecção de crises epilépticas em eletroencefalogramas |
| title_full_unstemmed |
Comparação de técnicas de classificação unária para detecção de crises epilépticas em eletroencefalogramas |
| title_sort |
Comparação de técnicas de classificação unária para detecção de crises epilépticas em eletroencefalogramas |
| author |
Leitão, Patrícia Tavares |
| author_facet |
Leitão, Patrícia Tavares |
| author_role |
author |
| dc.contributor.authorLattes.pt_BR.fl_str_mv |
http://lattes.cnpq.br/365921413 |
| dc.contributor.advisorORCID.pt_BR.fl_str_mv |
https://orcid.org/0000-0002-7002-1216 |
| dc.contributor.advisorLattes.pt_BR.fl_str_mv |
http://lattes.cnpq.br/8902002461422112 |
| dc.contributor.author.fl_str_mv |
Leitão, Patrícia Tavares |
| dc.contributor.advisor1.fl_str_mv |
Barreto, Guilherme de Alencar |
| contributor_str_mv |
Barreto, Guilherme de Alencar |
| dc.subject.cnpq.fl_str_mv |
CNPQ::ENGENHARIAS |
| topic |
CNPQ::ENGENHARIAS Crises Epilépticas Eletroencefalograma (EEG) Detecção de anomalias Classificação unária Aprendizado do computador Epilepsia Epileptic Seizures Electroencephalogram (EEG) Anomaly detection One-class classification Machine learning Epilepsy |
| dc.subject.ptbr.pt_BR.fl_str_mv |
Crises Epilépticas Eletroencefalograma (EEG) Detecção de anomalias Classificação unária Aprendizado do computador Epilepsia |
| dc.subject.en.pt_BR.fl_str_mv |
Epileptic Seizures Electroencephalogram (EEG) Anomaly detection One-class classification Machine learning Epilepsy |
| description |
The electroencephalogram (EEG) is a widely used test to support the diagnosis of neurological disorders. Among its applications, scalp EEG stands out, a non-invasive method widely used in the detection of epilepsy, performed by attaching electrodes to the surface of the scalp. In the field of machine learning, the identification of epileptic seizures is a recurring task, and for anomaly detection, two approaches are generally adopted: binary classification and unary classification. In this context, this work explores the application of unary classification (one-class classification) in EEG signals. Seven methods were analyzed: minimum Euclidean distance to the centroid, minimum kernel Euclidean distance to the centroid (KDEMC), minimum Mahalanobis distance to the centroid, PCA, kernel PCA (KPCA), one-class SVM and isolation forest. For this purpose, the public CHB-MIT Scalp EEG dataset was used, considering different hypotheses for extracting segments with seizure occurrence (ictal EEG) and without seizure occurrence (non-ictal EEG) to generate the training and test sets. Feature extraction was performed using the covariance vector, a fast and efficient method for the task in question. Furthermore, a comparative analysis was performed with literature studies that use the binary classification paradigm. Based on the analysis and discussion of the results, it was observed that among the unary classifiers evaluated, KDEMC and KPCA stand out, achieving maximum accuracy of 95.53% and 97.27%, sensitivity (recall) of 98.66% and 99.40%, and precision of 96.10% and 86.61%. The best unary classifiers achieve performances equivalent to the binary classifiers in the literature. |
| publishDate |
2025 |
| dc.date.issued.fl_str_mv |
2025 |
| dc.date.accessioned.fl_str_mv |
2026-11-03T17:42:53Z |
| dc.date.available.fl_str_mv |
2026-11-03T17:42:53Z |
| dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
| dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
| format |
masterThesis |
| status_str |
publishedVersion |
| dc.identifier.citation.fl_str_mv |
LEITÃO, Patrícia Tavares. Comparação de técnicas de classificação unária para detecção de crises epilépticas em eletroencefalogramas. 2025. Dissertação (Mestrado em Engenharia de Teleinformática) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2025. |
| dc.identifier.uri.fl_str_mv |
http://repositorio.ufc.br/handle/riufc/88425 |
| identifier_str_mv |
LEITÃO, Patrícia Tavares. Comparação de técnicas de classificação unária para detecção de crises epilépticas em eletroencefalogramas. 2025. Dissertação (Mestrado em Engenharia de Teleinformática) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2025. |
| url |
http://repositorio.ufc.br/handle/riufc/88425 |
| dc.language.iso.fl_str_mv |
por |
| language |
por |
| dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.source.none.fl_str_mv |
reponame:Repositório Institucional da Universidade Federal do Ceará (UFC) instname:Universidade Federal do Ceará (UFC) instacron:UFC |
| instname_str |
Universidade Federal do Ceará (UFC) |
| instacron_str |
UFC |
| institution |
UFC |
| reponame_str |
Repositório Institucional da Universidade Federal do Ceará (UFC) |
| collection |
Repositório Institucional da Universidade Federal do Ceará (UFC) |
| bitstream.url.fl_str_mv |
http://repositorio.ufc.br/bitstream/riufc/88425/3/2025_dis_ptleitao http://repositorio.ufc.br/bitstream/riufc/88425/4/license.txt |
| bitstream.checksum.fl_str_mv |
545181b2f2602cc4ce86211434abe350 8a4605be74aa9ea9d79846c1fba20a33 |
| bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 |
| repository.name.fl_str_mv |
Repositório Institucional da Universidade Federal do Ceará (UFC) - Universidade Federal do Ceará (UFC) |
| repository.mail.fl_str_mv |
bu@ufc.br || repositorio@ufc.br |
| _version_ |
1881776017468555264 |