Pressões respiratórias máximas: da busca de evidências à aplicabilidade clínica

Detalhes bibliográficos
Ano de defesa: 2022
Autor(a) principal: Bruna Mara Franco SIlveira
Orientador(a): Não Informado pela instituição
Banca de defesa: Não Informado pela instituição
Tipo de documento: Tese
Tipo de acesso: Acesso aberto
Idioma: por
Instituição de defesa: Universidade Federal de Minas Gerais
Programa de Pós-Graduação: Não Informado pela instituição
Departamento: Não Informado pela instituição
País: Não Informado pela instituição
Palavras-chave em Português:
Link de acesso: https://hdl.handle.net/1843/44281
Resumo: Maximal respiratory pressures (MRP) measurements are widely used to assess respiratory muscle strength. This is a simple, fast, non-invasive, and well-tolerated method in which individuals generate maximal inspiratory and expiratory pressures (PImax and PEmax, respectively) against an occluded mouthpiece. The values obtained during these measurements are influenced by the lung volume in which the test is performed. MRP measurements obtained at the functional residual capacity (FRC) level may minimize the influence of the elastic recoil pressure of the respiratory system on the measures. The aims of the present thesis were: i) to summarize and critically appraise the evidence on the measurement properties reliability and validity of MRP measurements using the COSMIN recommendations, ii) to evaluate concurrent validity of the TrueForce (LabCare/LEB – UFMG, Brazil) for MRP obtained at residual volume (RV) and total lung capacity (TLC), and test-retest and inter-rater reliability of MRP obtained at FRC with the TrueForce in healthy individuals, as well as to compare values obtained at different volumes in healthy individuals and individuals with COPD, iii) to compare inspiratory pressures obtained at functional residual capacity FRC with measures at RV, and expiratory pressures obtained at FRC with measures at TLC in individuals with health conditions (post-COVID-19, chronic obstructive pulmonary chronic, idiopathic pulmonary fibrosis, heart failure and stroke), and to compare the mean differences between measurements at FRC and RV/TLC among the groups, iv) to investigate the use of MRP by physiotherapists with experience in the cardiorespiratory and intensive care fields. The first study of this thesis is a systematic review that gathered studies evaluating the measurement properties reliability and validity of MRP. The literature search was performed in PubMed and EMBASE databases. This review was designed following the COSMIN recommendations, and reported according to PRISMA statement. Twenty-six studies were included. Test-retest reliability was graded as moderate level of evidence for PImax and PEmax, interrater reliability was low for PImax and very low for PEmax, and measurement error was very low for PImax and PEmax. Concurrent validity was graded as high level of evidence for PImax and PEmax. Test-retest and measurement error for PImax obtained at functional residual capacity were graded as very low quality evidence, with no sufficient evidence for conclusions on the other measurement properties and PEmax at FRC. For the second study, MRP of 100 healthy individuals were obtained using the TrueForce and the gold-standard (MicroRPM®) at RV and TLC to evaluate concurrent validity. MRP were obtained at FRC using the TrueForce to evaluate test-retest and interrater reliability. The intraclass correlation coefficient were 0.77 and 0.86 for concurrent validity for PImax and PEmax, respectively. The coefficients were 0.87 and 0.78 for test-retest reliability (PImax and PEmax, respectively) and 0.91 and 0.84 for inter-rater reliability (PImax and PEmax, respectively). MRP were lower When obtained at FRC for healthy individuals and with COPD. For the third study, inspiratory and expiratory pressures were obtained at RV, TLC and FRC in a random order with individuals with different health conditions (15 individuals were included in each group). Inspiratory pressures at FRC were lower than RV, and expiratory pressures at FRC were lower than TLC (p≤0.005 for all). The mean differences between PImax at RV and FRC were between 8.0 and 12.8 cmH2O, and the mean differences between PEmax at TLC and FRC were between 51.9 and 62.9 cmH2O. All mean differences were similar among groups (p≥0.227 for all). For the fourth study, an online, cross-sectional, survey was developed for physiotherapists in the cardiorespiratory and intensive care fields in Brazil, and sent via electronic mail. Of the 179 responses obtained, 168 were included in the analyses. Most physiotherapists reported that currently use (109/168, 65%), or already used MRP measurements (44/59, 75%). The majority reported using the aneroid manometer (70/109, 64%), choosing the reference values proposed by Neder et al. (35/109, 32%), recording peak (34/109, 31%) and sustained pressures (34/109, 31%), and performing the measurements at RV for PImax (59/109, 54%), and at TLC for PEmax (34/109, 31%). Most physiotherapists were not aware of all indications and contraindications for MRP measurements. Summarizing, the results of the four studies included in this thesis contribute to the knowledge regarding MRP measures, from the scientific evidence presented ins a systematic review to the understanding of the clinical applicability of the measures.
id UFMG_044243d3fd11b9ecf3b3e2cd76bc9ea1
oai_identifier_str oai:repositorio.ufmg.br:1843/44281
network_acronym_str UFMG
network_name_str Repositório Institucional da UFMG
repository_id_str
spelling Pressões respiratórias máximas: da busca de evidências à aplicabilidade clínicaMaximal respiratory pressures: from evidence search to clinical applicabilityPulmõesSistema respiratórioExercícios respiratóriosFisioterapiaCapacidade residual funcionalConfiabilidade e validadeMúsculos respiratóriosPressões respiratórias máximasQuestionárioMaximal respiratory pressures (MRP) measurements are widely used to assess respiratory muscle strength. This is a simple, fast, non-invasive, and well-tolerated method in which individuals generate maximal inspiratory and expiratory pressures (PImax and PEmax, respectively) against an occluded mouthpiece. The values obtained during these measurements are influenced by the lung volume in which the test is performed. MRP measurements obtained at the functional residual capacity (FRC) level may minimize the influence of the elastic recoil pressure of the respiratory system on the measures. The aims of the present thesis were: i) to summarize and critically appraise the evidence on the measurement properties reliability and validity of MRP measurements using the COSMIN recommendations, ii) to evaluate concurrent validity of the TrueForce (LabCare/LEB – UFMG, Brazil) for MRP obtained at residual volume (RV) and total lung capacity (TLC), and test-retest and inter-rater reliability of MRP obtained at FRC with the TrueForce in healthy individuals, as well as to compare values obtained at different volumes in healthy individuals and individuals with COPD, iii) to compare inspiratory pressures obtained at functional residual capacity FRC with measures at RV, and expiratory pressures obtained at FRC with measures at TLC in individuals with health conditions (post-COVID-19, chronic obstructive pulmonary chronic, idiopathic pulmonary fibrosis, heart failure and stroke), and to compare the mean differences between measurements at FRC and RV/TLC among the groups, iv) to investigate the use of MRP by physiotherapists with experience in the cardiorespiratory and intensive care fields. The first study of this thesis is a systematic review that gathered studies evaluating the measurement properties reliability and validity of MRP. The literature search was performed in PubMed and EMBASE databases. This review was designed following the COSMIN recommendations, and reported according to PRISMA statement. Twenty-six studies were included. Test-retest reliability was graded as moderate level of evidence for PImax and PEmax, interrater reliability was low for PImax and very low for PEmax, and measurement error was very low for PImax and PEmax. Concurrent validity was graded as high level of evidence for PImax and PEmax. Test-retest and measurement error for PImax obtained at functional residual capacity were graded as very low quality evidence, with no sufficient evidence for conclusions on the other measurement properties and PEmax at FRC. For the second study, MRP of 100 healthy individuals were obtained using the TrueForce and the gold-standard (MicroRPM®) at RV and TLC to evaluate concurrent validity. MRP were obtained at FRC using the TrueForce to evaluate test-retest and interrater reliability. The intraclass correlation coefficient were 0.77 and 0.86 for concurrent validity for PImax and PEmax, respectively. The coefficients were 0.87 and 0.78 for test-retest reliability (PImax and PEmax, respectively) and 0.91 and 0.84 for inter-rater reliability (PImax and PEmax, respectively). MRP were lower When obtained at FRC for healthy individuals and with COPD. For the third study, inspiratory and expiratory pressures were obtained at RV, TLC and FRC in a random order with individuals with different health conditions (15 individuals were included in each group). Inspiratory pressures at FRC were lower than RV, and expiratory pressures at FRC were lower than TLC (p≤0.005 for all). The mean differences between PImax at RV and FRC were between 8.0 and 12.8 cmH2O, and the mean differences between PEmax at TLC and FRC were between 51.9 and 62.9 cmH2O. All mean differences were similar among groups (p≥0.227 for all). For the fourth study, an online, cross-sectional, survey was developed for physiotherapists in the cardiorespiratory and intensive care fields in Brazil, and sent via electronic mail. Of the 179 responses obtained, 168 were included in the analyses. Most physiotherapists reported that currently use (109/168, 65%), or already used MRP measurements (44/59, 75%). The majority reported using the aneroid manometer (70/109, 64%), choosing the reference values proposed by Neder et al. (35/109, 32%), recording peak (34/109, 31%) and sustained pressures (34/109, 31%), and performing the measurements at RV for PImax (59/109, 54%), and at TLC for PEmax (34/109, 31%). Most physiotherapists were not aware of all indications and contraindications for MRP measurements. Summarizing, the results of the four studies included in this thesis contribute to the knowledge regarding MRP measures, from the scientific evidence presented ins a systematic review to the understanding of the clinical applicability of the measures.FAPEMIG - Fundação de Amparo à Pesquisa do Estado de Minas GeraisUniversidade Federal de Minas Gerais2022-08-16T17:13:51Z2025-09-09T00:30:21Z2022-08-16T17:13:51Z2022-02-10info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisapplication/pdfhttps://hdl.handle.net/1843/44281porBruna Mara Franco SIlveirainfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFMGinstname:Universidade Federal de Minas Gerais (UFMG)instacron:UFMG2025-09-09T18:12:19Zoai:repositorio.ufmg.br:1843/44281Repositório InstitucionalPUBhttps://repositorio.ufmg.br/oairepositorio@ufmg.bropendoar:2025-09-09T18:12:19Repositório Institucional da UFMG - Universidade Federal de Minas Gerais (UFMG)false
dc.title.none.fl_str_mv Pressões respiratórias máximas: da busca de evidências à aplicabilidade clínica
Maximal respiratory pressures: from evidence search to clinical applicability
title Pressões respiratórias máximas: da busca de evidências à aplicabilidade clínica
spellingShingle Pressões respiratórias máximas: da busca de evidências à aplicabilidade clínica
Bruna Mara Franco SIlveira
Pulmões
Sistema respiratório
Exercícios respiratórios
Fisioterapia
Capacidade residual funcional
Confiabilidade e validade
Músculos respiratórios
Pressões respiratórias máximas
Questionário
title_short Pressões respiratórias máximas: da busca de evidências à aplicabilidade clínica
title_full Pressões respiratórias máximas: da busca de evidências à aplicabilidade clínica
title_fullStr Pressões respiratórias máximas: da busca de evidências à aplicabilidade clínica
title_full_unstemmed Pressões respiratórias máximas: da busca de evidências à aplicabilidade clínica
title_sort Pressões respiratórias máximas: da busca de evidências à aplicabilidade clínica
author Bruna Mara Franco SIlveira
author_facet Bruna Mara Franco SIlveira
author_role author
dc.contributor.author.fl_str_mv Bruna Mara Franco SIlveira
dc.subject.por.fl_str_mv Pulmões
Sistema respiratório
Exercícios respiratórios
Fisioterapia
Capacidade residual funcional
Confiabilidade e validade
Músculos respiratórios
Pressões respiratórias máximas
Questionário
topic Pulmões
Sistema respiratório
Exercícios respiratórios
Fisioterapia
Capacidade residual funcional
Confiabilidade e validade
Músculos respiratórios
Pressões respiratórias máximas
Questionário
description Maximal respiratory pressures (MRP) measurements are widely used to assess respiratory muscle strength. This is a simple, fast, non-invasive, and well-tolerated method in which individuals generate maximal inspiratory and expiratory pressures (PImax and PEmax, respectively) against an occluded mouthpiece. The values obtained during these measurements are influenced by the lung volume in which the test is performed. MRP measurements obtained at the functional residual capacity (FRC) level may minimize the influence of the elastic recoil pressure of the respiratory system on the measures. The aims of the present thesis were: i) to summarize and critically appraise the evidence on the measurement properties reliability and validity of MRP measurements using the COSMIN recommendations, ii) to evaluate concurrent validity of the TrueForce (LabCare/LEB – UFMG, Brazil) for MRP obtained at residual volume (RV) and total lung capacity (TLC), and test-retest and inter-rater reliability of MRP obtained at FRC with the TrueForce in healthy individuals, as well as to compare values obtained at different volumes in healthy individuals and individuals with COPD, iii) to compare inspiratory pressures obtained at functional residual capacity FRC with measures at RV, and expiratory pressures obtained at FRC with measures at TLC in individuals with health conditions (post-COVID-19, chronic obstructive pulmonary chronic, idiopathic pulmonary fibrosis, heart failure and stroke), and to compare the mean differences between measurements at FRC and RV/TLC among the groups, iv) to investigate the use of MRP by physiotherapists with experience in the cardiorespiratory and intensive care fields. The first study of this thesis is a systematic review that gathered studies evaluating the measurement properties reliability and validity of MRP. The literature search was performed in PubMed and EMBASE databases. This review was designed following the COSMIN recommendations, and reported according to PRISMA statement. Twenty-six studies were included. Test-retest reliability was graded as moderate level of evidence for PImax and PEmax, interrater reliability was low for PImax and very low for PEmax, and measurement error was very low for PImax and PEmax. Concurrent validity was graded as high level of evidence for PImax and PEmax. Test-retest and measurement error for PImax obtained at functional residual capacity were graded as very low quality evidence, with no sufficient evidence for conclusions on the other measurement properties and PEmax at FRC. For the second study, MRP of 100 healthy individuals were obtained using the TrueForce and the gold-standard (MicroRPM®) at RV and TLC to evaluate concurrent validity. MRP were obtained at FRC using the TrueForce to evaluate test-retest and interrater reliability. The intraclass correlation coefficient were 0.77 and 0.86 for concurrent validity for PImax and PEmax, respectively. The coefficients were 0.87 and 0.78 for test-retest reliability (PImax and PEmax, respectively) and 0.91 and 0.84 for inter-rater reliability (PImax and PEmax, respectively). MRP were lower When obtained at FRC for healthy individuals and with COPD. For the third study, inspiratory and expiratory pressures were obtained at RV, TLC and FRC in a random order with individuals with different health conditions (15 individuals were included in each group). Inspiratory pressures at FRC were lower than RV, and expiratory pressures at FRC were lower than TLC (p≤0.005 for all). The mean differences between PImax at RV and FRC were between 8.0 and 12.8 cmH2O, and the mean differences between PEmax at TLC and FRC were between 51.9 and 62.9 cmH2O. All mean differences were similar among groups (p≥0.227 for all). For the fourth study, an online, cross-sectional, survey was developed for physiotherapists in the cardiorespiratory and intensive care fields in Brazil, and sent via electronic mail. Of the 179 responses obtained, 168 were included in the analyses. Most physiotherapists reported that currently use (109/168, 65%), or already used MRP measurements (44/59, 75%). The majority reported using the aneroid manometer (70/109, 64%), choosing the reference values proposed by Neder et al. (35/109, 32%), recording peak (34/109, 31%) and sustained pressures (34/109, 31%), and performing the measurements at RV for PImax (59/109, 54%), and at TLC for PEmax (34/109, 31%). Most physiotherapists were not aware of all indications and contraindications for MRP measurements. Summarizing, the results of the four studies included in this thesis contribute to the knowledge regarding MRP measures, from the scientific evidence presented ins a systematic review to the understanding of the clinical applicability of the measures.
publishDate 2022
dc.date.none.fl_str_mv 2022-08-16T17:13:51Z
2022-08-16T17:13:51Z
2022-02-10
2025-09-09T00:30:21Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/1843/44281
url https://hdl.handle.net/1843/44281
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Minas Gerais
publisher.none.fl_str_mv Universidade Federal de Minas Gerais
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFMG
instname:Universidade Federal de Minas Gerais (UFMG)
instacron:UFMG
instname_str Universidade Federal de Minas Gerais (UFMG)
instacron_str UFMG
institution UFMG
reponame_str Repositório Institucional da UFMG
collection Repositório Institucional da UFMG
repository.name.fl_str_mv Repositório Institucional da UFMG - Universidade Federal de Minas Gerais (UFMG)
repository.mail.fl_str_mv repositorio@ufmg.br
_version_ 1879513011481214976