Efeito agudo da pressão expiratória positiva sobre a capacidade de exercício em pacientes com doença pulmonar obstrutiva crônica

Detalhes bibliográficos
Ano de defesa: 2017
Autor(a) principal: Hugo Leonardo Alves Pereira
Orientador(a): Não Informado pela instituição
Banca de defesa: Não Informado pela instituição
Tipo de documento: Dissertação
Tipo de acesso: Acesso aberto
Idioma: por
Instituição de defesa: Universidade Federal de Minas Gerais
Programa de Pós-Graduação: Não Informado pela instituição
Departamento: Não Informado pela instituição
País: Não Informado pela instituição
Palavras-chave em Português:
Link de acesso: https://hdl.handle.net/1843/BUOS-AUMLDG
Resumo: Chronic obstructive pulmonary disease (COPD) is a multisystem, preventable, and treatable disease characterized by persistent airflow limitation. Patients afflicted with this disease have reduced exercise capacity and an investigation of strategies to improve this capacity becomes important. Among the instrumental devices for chest physiotherapy used to promote alveolar ventilation increase, the EPAP (Expiratory Positive Airway Pressure) is highlighted. In this study, it was hypothesized that the use of EPAP during or before exercise of constant load on the cycle ergometer may contribute to the increase of exercise capacity in patients with COPD. Thus, the primary aim of this study was to evaluate the acute effects of EPAP on exercise capacity in patients with COPD, through exercise time of a constant-load test on the cycle ergometer. The secondary aim was to assess responses of some respiratory pattern variables and thoracic chest wall operating volumes. With these aims, a quasiexperimental study, whose sample size was 34 subjects, being the present study performed with the participation of nine patients with moderate to very severe COPD, of both sexes, and age of 66 ± 8 years. Patients underwent three constant-load tests on the cycle ergometer with 80% of maximal exercise load, which was estimated byequation obtained for performance an incremental shuttle walk test. The constant-load tests were performed in three different conditions: EPAP 7.5 cmH2O during the test (Protocol 1 - P1), EPAP 7.5 cmH2O before the test (Protocol 2 - P2) and EPAP sham before the test (Protocol 3 - P3). During the tests, the respiratory pattern and the thoracoabdominal movement were recorded by use of optoelectronic plethysmography, and three moments were analyzed later: rest (M1), half of the time of the constant-load exercise (M2) and end time of the constant-load exercise (M3). The comparisons between the different protocols (P1, P2 and P3), between the different moments (M1, M2 and M3) and interaction effect (P x M) were performed by use of generalized estimating equations. A 5% alpha was considered significant. The post hoc comparisons were performed using the Bonferroni test. Statistical Package for Social Sciences (SPSS 15.0, Chicago, IL, USA) was used to analyze data, and they were presented as average and standard deviation. The P1 exercise time (124.44 ± 48.65 seconds) was significantly lower comparing to P2 (211.44 ± 105.76 seconds, p = 0.040) and P3 (228.22 ± 104.57 seconds; P = 0.017), with no significant difference between P2 and P3 (p = 0.186). The degree of dyspnea observed during P1 (7.78 ± 1.99) was significantly higher in relation to P2 (2.61 ± 1.74, p <0.001) and P3 (2.72 ± 1.62; p < 0.001) without significant difference between P2 and P3. The perception of effort in lower limbs was higher during P1 (6.33 ± 2.40) in relation to P2 (3.78 ± 2.53, p = 0.009) and P3 (3.55 ± 2.30; P = 0.046), with no significant difference between P2 and P3. Chest wall tidal volume (Vcw), respiratory rate (RR) and minute ventilation (VE) increased significantly with exercise progression in all protocols. The Vcw during P2 and P3 was statistically different from P1, independent of the moment analyzed. There was an increase of RR throughout the exercise in all protocols, however, without significant increase in the half of the exercise comparing to the rest and in the half of the exercise comparing to the end of the exercise in the P1. The VE increased significantly in all protocols. Regarding the chest wall volumes (inspiratory and end expiratory), no significant differences were found between rest and end of exercise in any of the protocols. In conclusion, the results of the present study demonstrated that the use of EPAP, with load of 7.5 cmH2O, during or before constant-load test was not able to increase the exercise capacity of the patients evaluated.
id UFMG_16c44ddfabb09ccfde2c49b30bbd44e7
oai_identifier_str oai:repositorio.ufmg.br:1843/BUOS-AUMLDG
network_acronym_str UFMG
network_name_str Repositório Institucional da UFMG
repository_id_str
spelling Efeito agudo da pressão expiratória positiva sobre a capacidade de exercício em pacientes com doença pulmonar obstrutiva crônicaFisioterapiaSistema respiratorioPulmões Doenças obstrutivasExercícios fisicosDoença pulmonar obstrutiva crônicaCapacidade de exercícioFisioterapia respiratóriaPressão expiratória positivaEpapChronic obstructive pulmonary disease (COPD) is a multisystem, preventable, and treatable disease characterized by persistent airflow limitation. Patients afflicted with this disease have reduced exercise capacity and an investigation of strategies to improve this capacity becomes important. Among the instrumental devices for chest physiotherapy used to promote alveolar ventilation increase, the EPAP (Expiratory Positive Airway Pressure) is highlighted. In this study, it was hypothesized that the use of EPAP during or before exercise of constant load on the cycle ergometer may contribute to the increase of exercise capacity in patients with COPD. Thus, the primary aim of this study was to evaluate the acute effects of EPAP on exercise capacity in patients with COPD, through exercise time of a constant-load test on the cycle ergometer. The secondary aim was to assess responses of some respiratory pattern variables and thoracic chest wall operating volumes. With these aims, a quasiexperimental study, whose sample size was 34 subjects, being the present study performed with the participation of nine patients with moderate to very severe COPD, of both sexes, and age of 66 ± 8 years. Patients underwent three constant-load tests on the cycle ergometer with 80% of maximal exercise load, which was estimated byequation obtained for performance an incremental shuttle walk test. The constant-load tests were performed in three different conditions: EPAP 7.5 cmH2O during the test (Protocol 1 - P1), EPAP 7.5 cmH2O before the test (Protocol 2 - P2) and EPAP sham before the test (Protocol 3 - P3). During the tests, the respiratory pattern and the thoracoabdominal movement were recorded by use of optoelectronic plethysmography, and three moments were analyzed later: rest (M1), half of the time of the constant-load exercise (M2) and end time of the constant-load exercise (M3). The comparisons between the different protocols (P1, P2 and P3), between the different moments (M1, M2 and M3) and interaction effect (P x M) were performed by use of generalized estimating equations. A 5% alpha was considered significant. The post hoc comparisons were performed using the Bonferroni test. Statistical Package for Social Sciences (SPSS 15.0, Chicago, IL, USA) was used to analyze data, and they were presented as average and standard deviation. The P1 exercise time (124.44 ± 48.65 seconds) was significantly lower comparing to P2 (211.44 ± 105.76 seconds, p = 0.040) and P3 (228.22 ± 104.57 seconds; P = 0.017), with no significant difference between P2 and P3 (p = 0.186). The degree of dyspnea observed during P1 (7.78 ± 1.99) was significantly higher in relation to P2 (2.61 ± 1.74, p <0.001) and P3 (2.72 ± 1.62; p < 0.001) without significant difference between P2 and P3. The perception of effort in lower limbs was higher during P1 (6.33 ± 2.40) in relation to P2 (3.78 ± 2.53, p = 0.009) and P3 (3.55 ± 2.30; P = 0.046), with no significant difference between P2 and P3. Chest wall tidal volume (Vcw), respiratory rate (RR) and minute ventilation (VE) increased significantly with exercise progression in all protocols. The Vcw during P2 and P3 was statistically different from P1, independent of the moment analyzed. There was an increase of RR throughout the exercise in all protocols, however, without significant increase in the half of the exercise comparing to the rest and in the half of the exercise comparing to the end of the exercise in the P1. The VE increased significantly in all protocols. Regarding the chest wall volumes (inspiratory and end expiratory), no significant differences were found between rest and end of exercise in any of the protocols. In conclusion, the results of the present study demonstrated that the use of EPAP, with load of 7.5 cmH2O, during or before constant-load test was not able to increase the exercise capacity of the patients evaluated.Universidade Federal de Minas Gerais2019-08-13T06:45:19Z2025-09-09T01:27:04Z2019-08-13T06:45:19Z2017-04-28info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfhttps://hdl.handle.net/1843/BUOS-AUMLDGHugo Leonardo Alves Pereirainfo:eu-repo/semantics/openAccessporreponame:Repositório Institucional da UFMGinstname:Universidade Federal de Minas Gerais (UFMG)instacron:UFMG2025-09-09T01:27:04Zoai:repositorio.ufmg.br:1843/BUOS-AUMLDGRepositório InstitucionalPUBhttps://repositorio.ufmg.br/oairepositorio@ufmg.bropendoar:2025-09-09T01:27:04Repositório Institucional da UFMG - Universidade Federal de Minas Gerais (UFMG)false
dc.title.none.fl_str_mv Efeito agudo da pressão expiratória positiva sobre a capacidade de exercício em pacientes com doença pulmonar obstrutiva crônica
title Efeito agudo da pressão expiratória positiva sobre a capacidade de exercício em pacientes com doença pulmonar obstrutiva crônica
spellingShingle Efeito agudo da pressão expiratória positiva sobre a capacidade de exercício em pacientes com doença pulmonar obstrutiva crônica
Hugo Leonardo Alves Pereira
Fisioterapia
Sistema respiratorio
Pulmões Doenças obstrutivas
Exercícios fisicos
Doença pulmonar obstrutiva crônica
Capacidade de exercício
Fisioterapia respiratória
Pressão expiratória positiva
Epap
title_short Efeito agudo da pressão expiratória positiva sobre a capacidade de exercício em pacientes com doença pulmonar obstrutiva crônica
title_full Efeito agudo da pressão expiratória positiva sobre a capacidade de exercício em pacientes com doença pulmonar obstrutiva crônica
title_fullStr Efeito agudo da pressão expiratória positiva sobre a capacidade de exercício em pacientes com doença pulmonar obstrutiva crônica
title_full_unstemmed Efeito agudo da pressão expiratória positiva sobre a capacidade de exercício em pacientes com doença pulmonar obstrutiva crônica
title_sort Efeito agudo da pressão expiratória positiva sobre a capacidade de exercício em pacientes com doença pulmonar obstrutiva crônica
author Hugo Leonardo Alves Pereira
author_facet Hugo Leonardo Alves Pereira
author_role author
dc.contributor.author.fl_str_mv Hugo Leonardo Alves Pereira
dc.subject.por.fl_str_mv Fisioterapia
Sistema respiratorio
Pulmões Doenças obstrutivas
Exercícios fisicos
Doença pulmonar obstrutiva crônica
Capacidade de exercício
Fisioterapia respiratória
Pressão expiratória positiva
Epap
topic Fisioterapia
Sistema respiratorio
Pulmões Doenças obstrutivas
Exercícios fisicos
Doença pulmonar obstrutiva crônica
Capacidade de exercício
Fisioterapia respiratória
Pressão expiratória positiva
Epap
description Chronic obstructive pulmonary disease (COPD) is a multisystem, preventable, and treatable disease characterized by persistent airflow limitation. Patients afflicted with this disease have reduced exercise capacity and an investigation of strategies to improve this capacity becomes important. Among the instrumental devices for chest physiotherapy used to promote alveolar ventilation increase, the EPAP (Expiratory Positive Airway Pressure) is highlighted. In this study, it was hypothesized that the use of EPAP during or before exercise of constant load on the cycle ergometer may contribute to the increase of exercise capacity in patients with COPD. Thus, the primary aim of this study was to evaluate the acute effects of EPAP on exercise capacity in patients with COPD, through exercise time of a constant-load test on the cycle ergometer. The secondary aim was to assess responses of some respiratory pattern variables and thoracic chest wall operating volumes. With these aims, a quasiexperimental study, whose sample size was 34 subjects, being the present study performed with the participation of nine patients with moderate to very severe COPD, of both sexes, and age of 66 ± 8 years. Patients underwent three constant-load tests on the cycle ergometer with 80% of maximal exercise load, which was estimated byequation obtained for performance an incremental shuttle walk test. The constant-load tests were performed in three different conditions: EPAP 7.5 cmH2O during the test (Protocol 1 - P1), EPAP 7.5 cmH2O before the test (Protocol 2 - P2) and EPAP sham before the test (Protocol 3 - P3). During the tests, the respiratory pattern and the thoracoabdominal movement were recorded by use of optoelectronic plethysmography, and three moments were analyzed later: rest (M1), half of the time of the constant-load exercise (M2) and end time of the constant-load exercise (M3). The comparisons between the different protocols (P1, P2 and P3), between the different moments (M1, M2 and M3) and interaction effect (P x M) were performed by use of generalized estimating equations. A 5% alpha was considered significant. The post hoc comparisons were performed using the Bonferroni test. Statistical Package for Social Sciences (SPSS 15.0, Chicago, IL, USA) was used to analyze data, and they were presented as average and standard deviation. The P1 exercise time (124.44 ± 48.65 seconds) was significantly lower comparing to P2 (211.44 ± 105.76 seconds, p = 0.040) and P3 (228.22 ± 104.57 seconds; P = 0.017), with no significant difference between P2 and P3 (p = 0.186). The degree of dyspnea observed during P1 (7.78 ± 1.99) was significantly higher in relation to P2 (2.61 ± 1.74, p <0.001) and P3 (2.72 ± 1.62; p < 0.001) without significant difference between P2 and P3. The perception of effort in lower limbs was higher during P1 (6.33 ± 2.40) in relation to P2 (3.78 ± 2.53, p = 0.009) and P3 (3.55 ± 2.30; P = 0.046), with no significant difference between P2 and P3. Chest wall tidal volume (Vcw), respiratory rate (RR) and minute ventilation (VE) increased significantly with exercise progression in all protocols. The Vcw during P2 and P3 was statistically different from P1, independent of the moment analyzed. There was an increase of RR throughout the exercise in all protocols, however, without significant increase in the half of the exercise comparing to the rest and in the half of the exercise comparing to the end of the exercise in the P1. The VE increased significantly in all protocols. Regarding the chest wall volumes (inspiratory and end expiratory), no significant differences were found between rest and end of exercise in any of the protocols. In conclusion, the results of the present study demonstrated that the use of EPAP, with load of 7.5 cmH2O, during or before constant-load test was not able to increase the exercise capacity of the patients evaluated.
publishDate 2017
dc.date.none.fl_str_mv 2017-04-28
2019-08-13T06:45:19Z
2019-08-13T06:45:19Z
2025-09-09T01:27:04Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/1843/BUOS-AUMLDG
url https://hdl.handle.net/1843/BUOS-AUMLDG
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Minas Gerais
publisher.none.fl_str_mv Universidade Federal de Minas Gerais
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFMG
instname:Universidade Federal de Minas Gerais (UFMG)
instacron:UFMG
instname_str Universidade Federal de Minas Gerais (UFMG)
instacron_str UFMG
institution UFMG
reponame_str Repositório Institucional da UFMG
collection Repositório Institucional da UFMG
repository.name.fl_str_mv Repositório Institucional da UFMG - Universidade Federal de Minas Gerais (UFMG)
repository.mail.fl_str_mv repositorio@ufmg.br
_version_ 1879513175443898368