Medição de força de mordida baseada em extensometria no elemento dentário
| Ano de defesa: | 2026 |
|---|---|
| Autor(a) principal: | |
| Orientador(a): | |
| Banca de defesa: | |
| Tipo de documento: | Dissertação |
| Tipo de acesso: | Acesso aberto |
| Idioma: | por |
| Instituição de defesa: |
Não Informado pela instituição
|
| Programa de Pós-Graduação: |
Pós-Graduação em Engenharia Elétrica
|
| Departamento: |
Não Informado pela instituição
|
| País: |
Não Informado pela instituição
|
| Palavras-chave em Português: | |
| Palavras-chave em Inglês: | |
| Área do conhecimento CNPq: | |
| Link de acesso: | https://ri.ufs.br/jspui/handle/riufs/25398 |
Resumo: | Bite force constitutes a relevant parameter for the diagnosis and treatment of oral pathologies. Several studies have search for to develop methods to assess bite force, considering its ability to detect issues related to masticatory efficiency, TMD, and bruxism. However, many devices for this type of measurement significantly interfere with oral anatomy, potentially causing discomfort to the patient and unreliable measurements. Thus, aiming to enable bite force measurement without interference in the natural oral anatomy, this dissertation presents the development, analysis, and investigation of a force measurement system based on strain gauges applied to a dental element, constructed using a 3D-printed photopolymer resin model. To conduct this study, two cylindrical load cells (one solid and one hollow), three 3D-printed models of teeth, and electrical resistance strain gauges were used; the gauges were bonded to the load cells and models using Loctite 496 adhesive. The results evidenced that the models exhibited linear behavior, and, in particular, the models with a 3 mm cavity preparation showed higher sensitivity compared to the solid (intact) models. It was also observed that better occlusal stability results in a lower standard deviation in measurements. Due to its high gain, the measurement system is significantly influenced by temperature, although this effect can be compensated. In this context, this dissertation proposes a new approach for bite force measurement with potential for diverse biomedical applications. |
| id |
UFS-2_2ffbcbc9d55f46c6fbdf96354f3fc6ff |
|---|---|
| oai_identifier_str |
oai:oai:ri.ufs.br:repo_01:riufs/25398 |
| network_acronym_str |
UFS-2 |
| network_name_str |
Repositório Institucional da UFS |
| repository_id_str |
|
| spelling |
Santos Júnior, Nilson RodriguesCarvalho, Ádan NunesCarvalho Filho, José Gilmar Nunes de2026-07-09T14:08:34Z2026-07-09T14:08:34Z2026-02-04SANTOS JÚNIOR, Nilson Rodrigues. Medição de força de mordida baseada em extensometria no elemento dentário. 2026. 64 f. Dissertação (Mestrado em Engenharia Elétrica) — Universidade Federal de Sergipe, São Cristóvão, 2026.https://ri.ufs.br/jspui/handle/riufs/25398Bite force constitutes a relevant parameter for the diagnosis and treatment of oral pathologies. Several studies have search for to develop methods to assess bite force, considering its ability to detect issues related to masticatory efficiency, TMD, and bruxism. However, many devices for this type of measurement significantly interfere with oral anatomy, potentially causing discomfort to the patient and unreliable measurements. Thus, aiming to enable bite force measurement without interference in the natural oral anatomy, this dissertation presents the development, analysis, and investigation of a force measurement system based on strain gauges applied to a dental element, constructed using a 3D-printed photopolymer resin model. To conduct this study, two cylindrical load cells (one solid and one hollow), three 3D-printed models of teeth, and electrical resistance strain gauges were used; the gauges were bonded to the load cells and models using Loctite 496 adhesive. The results evidenced that the models exhibited linear behavior, and, in particular, the models with a 3 mm cavity preparation showed higher sensitivity compared to the solid (intact) models. It was also observed that better occlusal stability results in a lower standard deviation in measurements. Due to its high gain, the measurement system is significantly influenced by temperature, although this effect can be compensated. In this context, this dissertation proposes a new approach for bite force measurement with potential for diverse biomedical applications.A força de mordida constitui um parâmetro relevante para o diagnóstico e o tratamento de patologias orais. Diversos trabalhos buscaram desenvolver métodos para avaliar a força de mordida, considerando a sua capacidade de detectar problemas relacionados a eficiência mastigatória, DTM e bruxismo. No entanto, muitos dispositivos para esse tipo de medição interferem significamente na anatomia da boca, podendo causar incômodos ao paciente e medições não confiáveis. Assim, com o intuito de proporcionar a medição da força de mordida, sem interferência na anatomia natural da boca, são apresentados nesta dissertação o desenvolvimento, a análise e a investigação de um sistema de medição de força baseado em extensometria na unidade dentária, construído por meio de um modelo impresso em 3D em resina fotopolimerizável. Para a realização deste trabalho, foram utilizadas duas células de carga cilíndricas (uma maciça e uma oca), três modelos impressos em 3D e extensômetros, fixados às células e aos modelos utilizando o adesivo Loctite 496. Os resultados evidenciaram que os modelos apresentaram comportamento linear e, em particular, os modelos com preparo cavitário de 3 mm, possuíram uma maior sensibilidade em relação aos modelos maciços (intactos), visto que apresentam menos material e assim conseguem deformar mais. Também foi observado que uma melhor estabilidade oclusal resulta em menor desvio padrão nas medições. O sistema de medição, devido ao seu alto ganho, é influenciado significativamente pela temperatura, embora essa seja passível de compensação. Nesse contexto, esta dissertação propõe uma nova abordagem para a medição de força de mordida, com potencial para diversas aplicações biomédicas.Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPESSão CristóvãoporEngenharia elétricaExtensômetroSaúde bucalExtensômetroMedição de forçaForça de mordidaStrain gaugeForce measureBite forceENGENHARIAS::ENGENHARIA ELETRICAMedição de força de mordida baseada em extensometria no elemento dentárioBite force measurement based on extensometry applied to a dental elementinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisPós-Graduação em Engenharia ElétricaUniversidade Federal de Sergipe (UFS)reponame:Repositório Institucional da UFSinstname:Universidade Federal de Sergipe (UFS)instacron:UFSinfo:eu-repo/semantics/openAccessLICENSElicense.txtlicense.txttext/plain; charset=utf-81475https://ri.ufs.br/jspui/bitstream/riufs/25398/1/license.txt098cbbf65c2c15e1fb2e49c5d306a44cMD51ORIGINALNILSON_RODRIGUES_SANTOS_JUNIOR.pdfNILSON_RODRIGUES_SANTOS_JUNIOR.pdfapplication/pdf17813792https://ri.ufs.br/jspui/bitstream/riufs/25398/2/NILSON_RODRIGUES_SANTOS_JUNIOR.pdf9693658c816969b07d456bc202bb8a48MD52riufs/253982026-07-09 11:08:34.63oai:oai:ri.ufs.br:repo_01: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Repositório InstitucionalPUBhttps://ri.ufs.br/oai/requestrepositorio@academico.ufs.bropendoar:2026-07-09T14:08:34Repositório Institucional da UFS - Universidade Federal de Sergipe (UFS)false |
| dc.title.pt_BR.fl_str_mv |
Medição de força de mordida baseada em extensometria no elemento dentário |
| dc.title.alternative.eng.fl_str_mv |
Bite force measurement based on extensometry applied to a dental element |
| title |
Medição de força de mordida baseada em extensometria no elemento dentário |
| spellingShingle |
Medição de força de mordida baseada em extensometria no elemento dentário Santos Júnior, Nilson Rodrigues Engenharia elétrica Extensômetro Saúde bucal Extensômetro Medição de força Força de mordida Strain gauge Force measure Bite force ENGENHARIAS::ENGENHARIA ELETRICA |
| title_short |
Medição de força de mordida baseada em extensometria no elemento dentário |
| title_full |
Medição de força de mordida baseada em extensometria no elemento dentário |
| title_fullStr |
Medição de força de mordida baseada em extensometria no elemento dentário |
| title_full_unstemmed |
Medição de força de mordida baseada em extensometria no elemento dentário |
| title_sort |
Medição de força de mordida baseada em extensometria no elemento dentário |
| author |
Santos Júnior, Nilson Rodrigues |
| author_facet |
Santos Júnior, Nilson Rodrigues |
| author_role |
author |
| dc.contributor.author.fl_str_mv |
Santos Júnior, Nilson Rodrigues |
| dc.contributor.advisor1.fl_str_mv |
Carvalho, Ádan Nunes |
| dc.contributor.advisor-co1.fl_str_mv |
Carvalho Filho, José Gilmar Nunes de |
| contributor_str_mv |
Carvalho, Ádan Nunes Carvalho Filho, José Gilmar Nunes de |
| dc.subject.por.fl_str_mv |
Engenharia elétrica Extensômetro Saúde bucal Extensômetro Medição de força Força de mordida |
| topic |
Engenharia elétrica Extensômetro Saúde bucal Extensômetro Medição de força Força de mordida Strain gauge Force measure Bite force ENGENHARIAS::ENGENHARIA ELETRICA |
| dc.subject.eng.fl_str_mv |
Strain gauge Force measure Bite force |
| dc.subject.cnpq.fl_str_mv |
ENGENHARIAS::ENGENHARIA ELETRICA |
| description |
Bite force constitutes a relevant parameter for the diagnosis and treatment of oral pathologies. Several studies have search for to develop methods to assess bite force, considering its ability to detect issues related to masticatory efficiency, TMD, and bruxism. However, many devices for this type of measurement significantly interfere with oral anatomy, potentially causing discomfort to the patient and unreliable measurements. Thus, aiming to enable bite force measurement without interference in the natural oral anatomy, this dissertation presents the development, analysis, and investigation of a force measurement system based on strain gauges applied to a dental element, constructed using a 3D-printed photopolymer resin model. To conduct this study, two cylindrical load cells (one solid and one hollow), three 3D-printed models of teeth, and electrical resistance strain gauges were used; the gauges were bonded to the load cells and models using Loctite 496 adhesive. The results evidenced that the models exhibited linear behavior, and, in particular, the models with a 3 mm cavity preparation showed higher sensitivity compared to the solid (intact) models. It was also observed that better occlusal stability results in a lower standard deviation in measurements. Due to its high gain, the measurement system is significantly influenced by temperature, although this effect can be compensated. In this context, this dissertation proposes a new approach for bite force measurement with potential for diverse biomedical applications. |
| publishDate |
2026 |
| dc.date.accessioned.fl_str_mv |
2026-07-09T14:08:34Z |
| dc.date.available.fl_str_mv |
2026-07-09T14:08:34Z |
| dc.date.issued.fl_str_mv |
2026-02-04 |
| dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
| dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
| format |
masterThesis |
| status_str |
publishedVersion |
| dc.identifier.citation.fl_str_mv |
SANTOS JÚNIOR, Nilson Rodrigues. Medição de força de mordida baseada em extensometria no elemento dentário. 2026. 64 f. Dissertação (Mestrado em Engenharia Elétrica) — Universidade Federal de Sergipe, São Cristóvão, 2026. |
| dc.identifier.uri.fl_str_mv |
https://ri.ufs.br/jspui/handle/riufs/25398 |
| identifier_str_mv |
SANTOS JÚNIOR, Nilson Rodrigues. Medição de força de mordida baseada em extensometria no elemento dentário. 2026. 64 f. Dissertação (Mestrado em Engenharia Elétrica) — Universidade Federal de Sergipe, São Cristóvão, 2026. |
| url |
https://ri.ufs.br/jspui/handle/riufs/25398 |
| dc.language.iso.fl_str_mv |
por |
| language |
por |
| dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.publisher.program.fl_str_mv |
Pós-Graduação em Engenharia Elétrica |
| dc.publisher.initials.fl_str_mv |
Universidade Federal de Sergipe (UFS) |
| dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UFS instname:Universidade Federal de Sergipe (UFS) instacron:UFS |
| instname_str |
Universidade Federal de Sergipe (UFS) |
| instacron_str |
UFS |
| institution |
UFS |
| reponame_str |
Repositório Institucional da UFS |
| collection |
Repositório Institucional da UFS |
| bitstream.url.fl_str_mv |
https://ri.ufs.br/jspui/bitstream/riufs/25398/1/license.txt https://ri.ufs.br/jspui/bitstream/riufs/25398/2/NILSON_RODRIGUES_SANTOS_JUNIOR.pdf |
| bitstream.checksum.fl_str_mv |
098cbbf65c2c15e1fb2e49c5d306a44c 9693658c816969b07d456bc202bb8a48 |
| bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 |
| repository.name.fl_str_mv |
Repositório Institucional da UFS - Universidade Federal de Sergipe (UFS) |
| repository.mail.fl_str_mv |
repositorio@academico.ufs.br |
| _version_ |
1876368580847599616 |