Sensing electroporation during pulsed electric fields

Detalhes bibliográficos
Ano de defesa: 2022
Autor(a) principal: Pintarelli, Guilherme Brasil
Orientador(a): Suzuki, Daniela Ota Hisayasu
Banca de defesa: Não Informado pela instituição
Tipo de documento: Tese
Tipo de acesso: Acesso aberto
Idioma: eng
Instituição de defesa: Não Informado pela instituição
Programa de Pós-Graduação: Não Informado pela instituição
Departamento: Não Informado pela instituição
País: Não Informado pela instituição
Link de acesso: https://repositorio.ufsc.br/handle/123456789/240958
Resumo: Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Elétrica, Florianópolis, 2022.
id UFSC_322bd74e59d6662f0bccd8f2eea82fe4
oai_identifier_str oai:repositorio.ufsc.br:123456789/240958
network_acronym_str UFSC
network_name_str Repositório Institucional da UFSC
repository_id_str
spelling Universidade Federal de Santa CatarinaPintarelli, Guilherme BrasilSuzuki, Daniela Ota Hisayasu2022-10-21T16:59:38Z2022-10-21T16:59:38Z2022378616https://repositorio.ufsc.br/handle/123456789/240958Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Elétrica, Florianópolis, 2022.Os campos elétricos pulsados (PEF) podem melhorar ou ser uma alternativa a métodos tradicionais nas áreas de medicina e biotecnologia. Os PEF provocam abertura de poros na membrana celular (eletroporação). A eletroporação pode ser utilizada na transferência de substâncias para células, tratamento de cânceres ou pasteurização não térmica. A eletroporação é um fenômeno dinâmico caracterizado por alterar a permeabilidade da membrana. Esta tese tem como objetivo desenvolver um método de sensoriamento para eletroporação durante o protocolo PEF. Propomos usar a corrente do PEF para feedback. Essa abordagem não é invasiva e pode ser implementada usando os eletrodos existentes. Os métodos de detecção propostos podem ser usados para modelagem e controle da eletroporação. Foram executados quatro experimentos: (i) Investigação dos efeitos da amplitude de PEF para eletroporação irreversível em S. cerevisiae com medição da viabilidade celular, medidas de impedância macroscópica, microscopia eletrônica de varredura e simulações numéricas. A eletroporação irreversível com 500 kV/m reduz os números de levedura aos níveis industriais para vinho. Foi detectado um aumento de 15% nas medições de corrente do PEF para uma diminuição de 100 vezes na viabilidade para 105 células/ml. A microscopia eletrônica mostra detalhes de danos na levedura. A corrente contínua é afetada por outros efeitos além da eletroporação, pois o PEF contém um amplo espectro de frequências, principalmente sub-10 kHz (tipicamente sinais pulsados de alta tensão). (ii) Investigamos o uso de corrente alternada sobreposta ao protocolo PEF para mitigar outros efeitos de interferências. Com COMSOL foram realizadas simulações de eletroporação de leveduras e demonstrado que a membrana e parede celular são suscetíveis à passagem da corrente de deslocamento iniciando entre 10 kHz a 10 MHz. Meios biológicos possuem uma caracterização particular no espectro de frequências. Esses contribuem com a maior parte da dispersão macroscópica tipo ß, característica de interesse no desenvolvimento de sensores. A medição de impedância em certas frequências pode ser usada para detectar eletroporação. (iii) Foi desenvolvido um gerador de sinais capaz gerar PEF com sobreposição de sinais arbitrários. O sistema desenvolvido gera formas de onda de até ± 85 V, 12 A e 100 kHz (THD < 2,5% a ± 30 Vpp). Phantoms de gel (com condutividade semelhante aos tecidos biológicos, 0,1 S/m em dezenas de kHz) e propensos a acumular íons nos eletrodos foram usados para estudar os efeitos da polarização. Os resultados não mostraram mudanças significativas de impedância em 100 kHz devido à polarização do eletrodo. A leitura em 100 kHz reduz erros devido à polarização dos eletrodos, e o sistema é satisfatório para avaliar respostas em 100 kHz com polarização DC. (iv) Foi realizado o estudo in vitro com S. Tuberosum utilizando protocolos PEF com seno sobreposto de 100 kHz. A análise da impedância complexa em função do PEF ainda não foi discutida na literatura. Os resultados mostram que certos níveis de PEF induzem uma redução no efeito capacitivo da amostra em 100 kHz (deslocamento de dispersão ß), e a capacitância não é mais a principal característica da amostra em experimentos de eletroporação irreversível do tecido.Abstract: Pulsed electric fields (PEF) can improve and be an alternative to traditional methods in the areas of medicine and biotechnology. PEF can open pores in the cell membrane; this phenomenon is called electroporation. Electroporation can be used to transfer substances to cells, treat cancers or non-thermal pasteurisation. Electroporation is a dynamic phenomenon characterized by altering the cell membrane permeability. This thesis aims to develop a sensing method for electroporation during the PEF protocol. We propose using the PEF current reading to get treatment feedback. This approach is non-invasive and can be implemented using the existing PEF electrodes. Ultimately the proposed methods can be used to better understand (e.g., modelling) and control electroporation. We executed four experiments to support the objective: (i) We investigated the effects of irreversible electroporation pulse amplitude on S. cerevisiae using cell viability tests, macroscopic impedance measurements, scanning electron microscopy and numerical simulations. Irreversible electroporation proved to reach active yeast limits established by wine standards within 500 kV/m. We detected a 15% increase in the pulse current measurements for a 100-fold yeast viability decrease to 105 cells/ml. Scanning electron microscopic show details of PEF-triggered yeast surface damage. The direct current is affected by other effects rather than electroporation as PEF contain a broad spectrum of frequencies, mainly sub-10 kHz (typically pulsed high voltage signals). (ii) We investigate the use of alternating current superposing the PEF protocol to mitigate other effects interferences. We used COMSOL simulations with yeast electroporation model to demonstrate that the cell membrane and wall are susceptible to the passage of the displacement current starting between 10 kHz to 10 MHz. The biological media have specific characterization in the broad frequency spectrum. Those contribute with most of macroscopic dispersion ß, which is used to development of biological sensors. We show that certain frequencies could be used to detect the occurrence of electroporation, i.e., dielectric dispersion modulated sensing. (iii) We developed a custom signal generator capable of creating the PEF protocol with overlapping arbitrary signals. The system generates waveforms up to ± 85 V, 12 A and 100 kHz (THD < 2.5% at ± 30 Vpp). We used gel phantoms (with conductivity similar to the biological tissues, 0.1 S/m in tens of kHz) and likely to accumulate ions in the electrodes interface to study polarization effects. The results showed no significant changes at 100 kHz due to electrode polarization. It can be concluded that the reading at 100 kHz mitigates errors due to the electrodes polarization, and the system is satisfactory for evaluating responses at 100 kHz with DC bias. (iv) We executed in vitro study on S. Tuberosum using PEF and 100 kHz superposed sine. The analysis of the complex impedance as a function of the PEF has not yet been discussed in the literature. Our results show that certain levels of PEF induce a reduction in the sample's capacitive effect at 100 kHz (ß dispersion shift), and the capacitance is no longer the main characteristic of the sample at tissue's irreversible electroporation experiments.145 p.| il., gráfs.engEngenharia elétricaCampos elétricosEletroporaçãoDielétricosBiosensoresImpedância (Eletricidade)Alta voltagemSensing electroporation during pulsed electric fieldsinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisreponame:Repositório Institucional da UFSCinstname:Universidade Federal de Santa Catarina (UFSC)instacron:UFSCinfo:eu-repo/semantics/openAccessORIGINALPEEL2083-T.pdfPEEL2083-T.pdfapplication/pdf24645491https://repositorio.ufsc.br/bitstream/123456789/240958/-1/PEEL2083-T.pdfd13685fa00a15dbc0e5a48b30c6de5b0MD5-1123456789/2409582022-10-21 13:59:38.154oai:repositorio.ufsc.br:123456789/240958Repositório InstitucionalPUBhttp://150.162.242.35/oai/requestsandra.sobrera@ufsc.bropendoar:23732022-10-21T16:59:38Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)false
dc.title.none.fl_str_mv Sensing electroporation during pulsed electric fields
title Sensing electroporation during pulsed electric fields
spellingShingle Sensing electroporation during pulsed electric fields
Pintarelli, Guilherme Brasil
Engenharia elétrica
Campos elétricos
Eletroporação
Dielétricos
Biosensores
Impedância (Eletricidade)
Alta voltagem
title_short Sensing electroporation during pulsed electric fields
title_full Sensing electroporation during pulsed electric fields
title_fullStr Sensing electroporation during pulsed electric fields
title_full_unstemmed Sensing electroporation during pulsed electric fields
title_sort Sensing electroporation during pulsed electric fields
author Pintarelli, Guilherme Brasil
author_facet Pintarelli, Guilherme Brasil
author_role author
dc.contributor.none.fl_str_mv Universidade Federal de Santa Catarina
dc.contributor.author.fl_str_mv Pintarelli, Guilherme Brasil
dc.contributor.advisor1.fl_str_mv Suzuki, Daniela Ota Hisayasu
contributor_str_mv Suzuki, Daniela Ota Hisayasu
dc.subject.classification.none.fl_str_mv Engenharia elétrica
Campos elétricos
Eletroporação
Dielétricos
Biosensores
Impedância (Eletricidade)
Alta voltagem
topic Engenharia elétrica
Campos elétricos
Eletroporação
Dielétricos
Biosensores
Impedância (Eletricidade)
Alta voltagem
description Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Elétrica, Florianópolis, 2022.
publishDate 2022
dc.date.accessioned.fl_str_mv 2022-10-21T16:59:38Z
dc.date.available.fl_str_mv 2022-10-21T16:59:38Z
dc.date.issued.fl_str_mv 2022
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://repositorio.ufsc.br/handle/123456789/240958
dc.identifier.other.none.fl_str_mv 378616
identifier_str_mv 378616
url https://repositorio.ufsc.br/handle/123456789/240958
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 145 p.| il., gráfs.
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFSC
instname:Universidade Federal de Santa Catarina (UFSC)
instacron:UFSC
instname_str Universidade Federal de Santa Catarina (UFSC)
instacron_str UFSC
institution UFSC
reponame_str Repositório Institucional da UFSC
collection Repositório Institucional da UFSC
bitstream.url.fl_str_mv https://repositorio.ufsc.br/bitstream/123456789/240958/-1/PEEL2083-T.pdf
bitstream.checksum.fl_str_mv d13685fa00a15dbc0e5a48b30c6de5b0
bitstream.checksumAlgorithm.fl_str_mv MD5
repository.name.fl_str_mv Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)
repository.mail.fl_str_mv sandra.sobrera@ufsc.br
_version_ 1851759089163436032