Implantes pós exodônticos em área estética – controle de um ano

Detalhes bibliográficos
Ano de defesa: 2016
Autor(a) principal: Aur Junior, Roberto Jorge lattes
Orientador(a): Gulinelli, Jéssica Lemos lattes
Banca de defesa: Não Informado pela instituição
Tipo de documento: Tese
Tipo de acesso: Acesso aberto
Idioma: por
Instituição de defesa: Universidade do Sagrado Coração
Programa de Pós-Graduação: Cirurgia Bucomaxilofacial
Departamento: Ciências da Saúde e Biológicas
País: Brasil
Palavras-chave em Português:
Palavras-chave em Inglês:
Área do conhecimento CNPq:
Link de acesso: http://tede2.usc.br:8080/jspui/handle/tede/364
Resumo: Rehabilitation with implants is safe and predictable procedure. However, the treatment time is still a limiting factor for patient satisfaction. The tooth extraction and immediate implant insertion has been used and has many advantages, especially in relation to maintaining aesthetic and marginal peri-implant bone loss. The aim of the study was to evaluate the clinical efficacy and volumetric changes in bone level using computed tomography unit rehabilitations in previous aesthetic areas after post exodontics implant and immediate loading. The evaluated were: size of the implant insertion torque, tomographic peri-implant bone change, prosthetic complications and survival of the implant. The first CT scan was performed immediately after surgery (T0) and the second after a year of rehabilitation (T1). Ten patients were included in this study and a total of 10 implants placed in alveolus of the maxillary central incisors immediately without minimally invasive flapless extraction. The space formed between the alveolar wall and the implant surface were filled with bovine bone mineralization. All implants placed presented cone Morse connection, the average length was 15.4 mm and 3.5 mm in diameter. The average insertion torque was 60 N. There was no loss of the implant. The mean reduction (T1-T0) the horizontal distance between the width of the implant surface and the inside of the buccal bone (S - CI) was 0.347 (35%), with a statistically significant difference (p = 0.031250) the horizontal distance across the width of the implant surface and the outside of the vestibular bone (Y - CB) was 2.53 (25%), the average of the vertical distance between the center of the implant and the top of the crest of bone (CR) was 4.26 (43%) and the average thickness of the vestibular bone 0.23 (2%). The results demonstrate the maintenance of the peri-implant tissues, maintenance of interdental papilla, no inflammation and bone loss and adequate aesthetic evaluation after 12 months. It is concluded that post exodontias implants subjected to immediate loading unit in previous edentulous regions approach is predictable with high survival rate of the implant and promotes the maintenance of buccal bone wall
id USC_e3576b31be08ceb8be3c4e4158479ad0
oai_identifier_str oai:localhost:tede/364
network_acronym_str USC
network_name_str Biblioteca Digital de Teses e Dissertações da USC
repository_id_str
spelling Gulinelli, Jéssica Lemoshttp://lattes.cnpq.br/812840111972251616.696.761064.282.068-62http://lattes.cnpq.br/2425021037909455Aur Junior, Roberto Jorge2017-09-26T00:19:50Z2016-06-22AUR JUNIOR, Roberto Jorge. Implantes pós exodônticos em área estética – controle de um ano. 2016. 42 f. Tese (Doutorado em Odontologia - Área de Concentração: Cirurgia Bucomaxilofacial) - Universidade do Sagrado Coração, Bauru, 2016.http://tede2.usc.br:8080/jspui/handle/tede/364Rehabilitation with implants is safe and predictable procedure. However, the treatment time is still a limiting factor for patient satisfaction. The tooth extraction and immediate implant insertion has been used and has many advantages, especially in relation to maintaining aesthetic and marginal peri-implant bone loss. The aim of the study was to evaluate the clinical efficacy and volumetric changes in bone level using computed tomography unit rehabilitations in previous aesthetic areas after post exodontics implant and immediate loading. The evaluated were: size of the implant insertion torque, tomographic peri-implant bone change, prosthetic complications and survival of the implant. The first CT scan was performed immediately after surgery (T0) and the second after a year of rehabilitation (T1). Ten patients were included in this study and a total of 10 implants placed in alveolus of the maxillary central incisors immediately without minimally invasive flapless extraction. The space formed between the alveolar wall and the implant surface were filled with bovine bone mineralization. All implants placed presented cone Morse connection, the average length was 15.4 mm and 3.5 mm in diameter. The average insertion torque was 60 N. There was no loss of the implant. The mean reduction (T1-T0) the horizontal distance between the width of the implant surface and the inside of the buccal bone (S - CI) was 0.347 (35%), with a statistically significant difference (p = 0.031250) the horizontal distance across the width of the implant surface and the outside of the vestibular bone (Y - CB) was 2.53 (25%), the average of the vertical distance between the center of the implant and the top of the crest of bone (CR) was 4.26 (43%) and the average thickness of the vestibular bone 0.23 (2%). The results demonstrate the maintenance of the peri-implant tissues, maintenance of interdental papilla, no inflammation and bone loss and adequate aesthetic evaluation after 12 months. It is concluded that post exodontias implants subjected to immediate loading unit in previous edentulous regions approach is predictable with high survival rate of the implant and promotes the maintenance of buccal bone wallO implante dentário com conexão cone Morse tem sido muito utilizado e apresenta vantagens, especialmente em relação à manutenção da estética e da perda óssea marginal peri-implantar. O objetivo do estudo foi avaliar as variações volumétricas do nível ósseo de implantes pós exodônticos com carga imediata em área estética anterior utilizando a tomografia computadorizada no período de um ano. Dez pacientes participaram deste estudo e um total de 10 implantes com conexão do tipo Cone Morse foram instalados em alvéolos de incisivos centrais superiores, imediatamente à exodontia minimamente invasiva sem retalho. O espaço formado entre a parede alveolar e a superfície do implante foi preenchido com osso bovino mineralizado. O comprimento médio dos implantes foi de 15,4 mm e 3,5 mm de diâmetro. O torque médio de inserção foi de 60 N. Não houve perda de implante. A primeira tomografia foi realizada imediatamente após a cirurgia (T0) e a segunda após um ano da reabilitação (T1). A média da redução (T1-T0) da distância horizontal entre a largura da superfície do implante e da parte interna do osso vestibular (S – IC), foi de 0,347 (35%) com diferença estatisticamente significante (p=0,031250),a da distância horizontal entre a largura da superfície do implante e da parte externa do osso vestibular (S – OC) foi de 2,53 (25%), a média da distância vertical entre o centro do implante e a parte superior da crista do osso (R-C) foi de 4,26 (43%) e a média da espessura óssea vestibular foi 0,23 (2%). Os resultados demonstraram a manutenção dos tecidos peri-implantares e perda óssea compatível com os dados científicos após avaliação de 12 meses. Conclui-se que os implantes com conexão cone Morse pós exodônticos submetidos à estética imediata em regiões unitárias edêntulas anteriores é uma abordagem previsível, com elevada taxa de sobrevivência do implante e favorece a manutenção da parede óssea vestibularSubmitted by Laudeceia Machado (laudeceia.machado@usc.br) on 2017-09-13T21:39:53Z No. of bitstreams: 1 Implantes pos exodonticos em area estetica - controle de um ano (208318).pdf: 2034165 bytes, checksum: 227b6928356ba9b111cc79e44cf1f591 (MD5)Approved for entry into archive by Laudeceia Machado (laudeceia.machado@usc.br) on 2017-09-26T00:18:25Z (GMT) No. of bitstreams: 1 Implantes pos exodonticos em area estetica - controle de um ano (208318).pdf: 2034165 bytes, checksum: 227b6928356ba9b111cc79e44cf1f591 (MD5)Approved for entry into archive by Laudeceia Machado (laudeceia.machado@usc.br) on 2017-09-26T00:19:50Z (GMT) No. of bitstreams: 1 Implantes pos exodonticos em area estetica - controle de um ano (208318).pdf: 2034165 bytes, checksum: 227b6928356ba9b111cc79e44cf1f591 (MD5)Made available in DSpace on 2017-09-26T00:19:50Z (GMT). No. of bitstreams: 1 Implantes pos exodonticos em area estetica - controle de um ano (208318).pdf: 2034165 bytes, checksum: 227b6928356ba9b111cc79e44cf1f591 (MD5) Previous issue date: 2016-06-22application/pdfporUniversidade do Sagrado CoraçãoCirurgia BucomaxilofacialUSCBrasilCiências da Saúde e BiológicasEstéticaImplante dentárioMaxilaTomografia computadorizadaAestheticDental implantMaxillaTomographyODONTOLOGIA::CIRURGIA BUCO-MAXILO-FACIALImplantes pós exodônticos em área estética – controle de um anoPost-Exodontic implants in aesthetic area - one-year controlinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesis-6325264627946202213600600600-7534288876771829636481503023822191279info:eu-repo/semantics/openAccessreponame:Biblioteca Digital de Teses e Dissertações da USCinstname:Universidade do Sagrado Coração (USC)instacron:USCORIGINALImplantes pos exodonticos em area estetica - controle de um ano (208318).pdfImplantes pos exodonticos em area estetica - controle de um ano (208318).pdfapplication/pdf2034165http://localhost:8080/tede/bitstream/tede/364/2/Implantes+pos+exodonticos+em+area+estetica+-+controle+de+um+ano+%28208318%29.pdf227b6928356ba9b111cc79e44cf1f591MD52LICENSElicense.txtlicense.txttext/plain; charset=utf-82165http://localhost:8080/tede/bitstream/tede/364/1/license.txtbd3efa91386c1718a7f26a329fdcb468MD51tede/3642017-09-25 21:19:50.166oai:localhost: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Biblioteca Digital de Teses e Dissertaçõeshttps://tede2.usc.br:8443/http://tede2.usc.br:8080/oai/requestbiblicorjesu@unisagrado.edu.br||normalizacao@usc.bropendoar:2017-09-26T00:19:50Biblioteca Digital de Teses e Dissertações da USC - Universidade do Sagrado Coração (USC)false
dc.title.eng.fl_str_mv Implantes pós exodônticos em área estética – controle de um ano
dc.title.alternative.eng.fl_str_mv Post-Exodontic implants in aesthetic area - one-year control
title Implantes pós exodônticos em área estética – controle de um ano
spellingShingle Implantes pós exodônticos em área estética – controle de um ano
Aur Junior, Roberto Jorge
Estética
Implante dentário
Maxila
Tomografia computadorizada
Aesthetic
Dental implant
Maxilla
Tomography
ODONTOLOGIA::CIRURGIA BUCO-MAXILO-FACIAL
title_short Implantes pós exodônticos em área estética – controle de um ano
title_full Implantes pós exodônticos em área estética – controle de um ano
title_fullStr Implantes pós exodônticos em área estética – controle de um ano
title_full_unstemmed Implantes pós exodônticos em área estética – controle de um ano
title_sort Implantes pós exodônticos em área estética – controle de um ano
author Aur Junior, Roberto Jorge
author_facet Aur Junior, Roberto Jorge
author_role author
dc.contributor.advisor1.fl_str_mv Gulinelli, Jéssica Lemos
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/8128401119722516
dc.contributor.authorID.fl_str_mv 16.696.761
064.282.068-62
dc.contributor.authorLattes.fl_str_mv http://lattes.cnpq.br/2425021037909455
dc.contributor.author.fl_str_mv Aur Junior, Roberto Jorge
contributor_str_mv Gulinelli, Jéssica Lemos
dc.subject.por.fl_str_mv Estética
Implante dentário
Maxila
Tomografia computadorizada
topic Estética
Implante dentário
Maxila
Tomografia computadorizada
Aesthetic
Dental implant
Maxilla
Tomography
ODONTOLOGIA::CIRURGIA BUCO-MAXILO-FACIAL
dc.subject.eng.fl_str_mv Aesthetic
Dental implant
Maxilla
Tomography
dc.subject.cnpq.fl_str_mv ODONTOLOGIA::CIRURGIA BUCO-MAXILO-FACIAL
description Rehabilitation with implants is safe and predictable procedure. However, the treatment time is still a limiting factor for patient satisfaction. The tooth extraction and immediate implant insertion has been used and has many advantages, especially in relation to maintaining aesthetic and marginal peri-implant bone loss. The aim of the study was to evaluate the clinical efficacy and volumetric changes in bone level using computed tomography unit rehabilitations in previous aesthetic areas after post exodontics implant and immediate loading. The evaluated were: size of the implant insertion torque, tomographic peri-implant bone change, prosthetic complications and survival of the implant. The first CT scan was performed immediately after surgery (T0) and the second after a year of rehabilitation (T1). Ten patients were included in this study and a total of 10 implants placed in alveolus of the maxillary central incisors immediately without minimally invasive flapless extraction. The space formed between the alveolar wall and the implant surface were filled with bovine bone mineralization. All implants placed presented cone Morse connection, the average length was 15.4 mm and 3.5 mm in diameter. The average insertion torque was 60 N. There was no loss of the implant. The mean reduction (T1-T0) the horizontal distance between the width of the implant surface and the inside of the buccal bone (S - CI) was 0.347 (35%), with a statistically significant difference (p = 0.031250) the horizontal distance across the width of the implant surface and the outside of the vestibular bone (Y - CB) was 2.53 (25%), the average of the vertical distance between the center of the implant and the top of the crest of bone (CR) was 4.26 (43%) and the average thickness of the vestibular bone 0.23 (2%). The results demonstrate the maintenance of the peri-implant tissues, maintenance of interdental papilla, no inflammation and bone loss and adequate aesthetic evaluation after 12 months. It is concluded that post exodontias implants subjected to immediate loading unit in previous edentulous regions approach is predictable with high survival rate of the implant and promotes the maintenance of buccal bone wall
publishDate 2016
dc.date.issued.fl_str_mv 2016-06-22
dc.date.accessioned.fl_str_mv 2017-09-26T00:19:50Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv AUR JUNIOR, Roberto Jorge. Implantes pós exodônticos em área estética – controle de um ano. 2016. 42 f. Tese (Doutorado em Odontologia - Área de Concentração: Cirurgia Bucomaxilofacial) - Universidade do Sagrado Coração, Bauru, 2016.
dc.identifier.uri.fl_str_mv http://tede2.usc.br:8080/jspui/handle/tede/364
identifier_str_mv AUR JUNIOR, Roberto Jorge. Implantes pós exodônticos em área estética – controle de um ano. 2016. 42 f. Tese (Doutorado em Odontologia - Área de Concentração: Cirurgia Bucomaxilofacial) - Universidade do Sagrado Coração, Bauru, 2016.
url http://tede2.usc.br:8080/jspui/handle/tede/364
dc.language.iso.fl_str_mv por
language por
dc.relation.program.fl_str_mv -6325264627946202213
dc.relation.confidence.fl_str_mv 600
600
600
dc.relation.department.fl_str_mv -753428887677182963
dc.relation.cnpq.fl_str_mv 6481503023822191279
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade do Sagrado Coração
dc.publisher.program.fl_str_mv Cirurgia Bucomaxilofacial
dc.publisher.initials.fl_str_mv USC
dc.publisher.country.fl_str_mv Brasil
dc.publisher.department.fl_str_mv Ciências da Saúde e Biológicas
publisher.none.fl_str_mv Universidade do Sagrado Coração
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações da USC
instname:Universidade do Sagrado Coração (USC)
instacron:USC
instname_str Universidade do Sagrado Coração (USC)
instacron_str USC
institution USC
reponame_str Biblioteca Digital de Teses e Dissertações da USC
collection Biblioteca Digital de Teses e Dissertações da USC
bitstream.url.fl_str_mv http://localhost:8080/tede/bitstream/tede/364/2/Implantes+pos+exodonticos+em+area+estetica+-+controle+de+um+ano+%28208318%29.pdf
http://localhost:8080/tede/bitstream/tede/364/1/license.txt
bitstream.checksum.fl_str_mv 227b6928356ba9b111cc79e44cf1f591
bd3efa91386c1718a7f26a329fdcb468
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da USC - Universidade do Sagrado Coração (USC)
repository.mail.fl_str_mv biblicorjesu@unisagrado.edu.br||normalizacao@usc.br
_version_ 1831315073422852096