Avaliação fotoelástica de estresse peri-implantar em função da inclinação do implante e da extensão do cantilever em próteses múltiplas
| Ano de defesa: | 2013 |
|---|---|
| Autor(a) principal: | |
| Orientador(a): | |
| Banca de defesa: | |
| Tipo de documento: | Dissertação |
| Tipo de acesso: | Acesso aberto |
| Idioma: | por |
| Instituição de defesa: |
[s.n.]
|
| Programa de Pós-Graduação: |
Não Informado pela instituição
|
| Departamento: |
Não Informado pela instituição
|
| País: |
Não Informado pela instituição
|
| Palavras-chave em Português: | |
| Link de acesso: | https://biblioteca.slmandic.edu.br/TerminalWebRI/acervo/detalhe/61690 |
Resumo: | Dissertação (Mestrado em Implantodontia) - Centro de Pesquisas Odontológicas São Leopoldo Mandic. |
| id |
SLMC-1_d6eb207a011a24cfecbdace7851fc5f3 |
|---|---|
| oai_identifier_str |
oai:prima.com.br:61690 |
| network_acronym_str |
SLMC-1 |
| network_name_str |
Biblioteca Digital de Teses e Dissertações da Faculdade São Leopoldo Mandic |
| repository_id_str |
|
| spelling |
Avaliação fotoelástica de estresse peri-implantar em função da inclinação do implante e da extensão do cantilever em próteses múltiplasImplante dentárioPrótese dentáriaDissertação (Mestrado em Implantodontia) - Centro de Pesquisas Odontológicas São Leopoldo Mandic.O emprego de implantes inclinados e as extensões em cantilever ainda não possuem esclarecimento científico suficiente, principalmente com relação a associação de ambos. O presente estudo avaliou a distribuição de tensão peri-implantar, por fotoelasticidade, quando da simulação de diferentes inclinações do implante adjacente ao cantilever, o qual também foi testado em diferentes posições. Foram confeccionados quatro modelos (M0, M15, M30 e M45), em resina epóxi, com dois implantes posicionados. No primeiro modelo (M0), os dois elementos apresentaram-se axiais; no segundo modelo (M15), um dos implantes teve inclinação de 15°; no terceiro modelo (M30), um dos implantes teve 30° e, no último modelo (M45), o implante teve 45°. Sobre os implantes foram construídas infraestruturas em titânio que possibilitaram simular o comportamento de uma prótese parcial fixa com extensão em cantilever. A avaliação das tensões peri-implantares foi realizada por meio da adaptação de um polariscópio circular à máquina de ensaio universal (EMIC) que possibilitou a aplicação de cargas axiais nos pontos pré-determinados. As franjas isocromáticas geradas nos modelos, foram registradas por fotografia, antes e após à aplicação das cargas em cada ponto. Foi realizada a análise qualitativa das franjas geradas em cada região, bem como a contagem do número de franjas em cada implante e em cada modelo. Para o implante adjacente ao cantilever (implante 2) os resultados mostraram diferentes comportamentos das franjas, sendo que, para o modelo sem inclinação (M0), a concentração de tensões localizou-se na região apical, enquanto que para os modelos com inclinação (M15, M30, M45) houve uma migração progressiva da concentração de tensões para a região cervical do implante. Na comparação entre o modelo sem inclinação e com aplicação de carga sobre o extremo do cantilever e os modelos com inclinação e aplicação de carga sobre o coping, foi verificada menor incidência de franjas no primeiro, em comparação com qualquer inclinação avaliada. Houve também maior tensão, em menor ou maior proporção, nos implantes que estavam distantes do cantilever (implante 1). O modelo de maior incidência de franjas foi o M45, quando houve aplicação de carga sobre o extremo do cantilever, com franjas perpendiculares presentes, tanto na região cervical, quanto na região apical do implante mais próximo ao cantilever (implante 2). Esse estudo pode concluir, do ponto de vista peri-implantar, que a associação do cantilever com a inclinação em 45° elevou significativamente a concentração de tensão peri-implantar, representando um fator de risco biomecânico. Palavras-chave: Implantes dentários. Prótese dentária. Biomecânica. The use of tilted implants and cantilever extensions do not yet have sufficient scientific enlightenment, especially about to the both combination. The present study evaluated the stress periimplant distribution by photoelasticity when simulating differents implant inclinations adjacent to the cantilever, which was also tested in different positions. Four models were made (M0, M15, M30 and M45), from epoxy resin, with two implants positioned. In the first model (M0), two elements were presented axial; in the second model (M15), one of the implants had inclination of 15°; the third model (M30), one of the implants was 30° and in the latter model (M45), the implant was 45°. Over the implants were built titanium frameworks that possible simulate the behavior of a fixed partial denture with cantilever extension. The evaluation of strains peri-implant was performed by fitting of a circular polariscope to a universal testing machine (EMIC), which allowed the application of axial loads in predetermined points. The isochromatic fringes generated in the models were recorded by photography before and after the application of loads at each point. A qualitative analysis was performed of the fringes generated in each region, as well the counting the number of fringes in each implant and in each model. For the implant adjacent to the cantilever (implant 2), the results showed different behaviors of the fringes, being that the model without tilting (M0), the stress concentration was located in the apical region, while for models with tilting (M15, M30, M45) there was a progressive migration of stress concentration for the cervical region of the implant. In comparison between the model with no inclination and applying load on the cantilever end and the models with inclination and application over coping, lower fringes incidence was observed in the first, compared with any inclination evaluated. There was also higher strain, in a greater or lesser extent on the implants that were distant from the cantilever (implant 1). The model with the highest incidence of fringes was the M45, when there was load application on the end of the cantilever, with perpendicular fringes present, both cervical region and apical region of the implant closet to the cantilever (implant 2). This study may conclude, from the peri-implant viewpoint, the association of the cantilever with the inclination at 45° elevated significantly the peri-implant stress concentration, representing a biomechanical risk factor. Keywords: Dental implants. Dental prosthesis. Biomechanics.[s.n.]Vedovatto, EduardoCentro de Pesquisas Odontológicas São Leopoldo MandicMählmann, Vanessa de Fátima Silva dos Santos2013info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdf65 f. : il.https://biblioteca.slmandic.edu.br/TerminalWebRI/acervo/detalhe/61690porhttps://biblioteca.slmandic.edu.br/TerminalWebRI/acervo/detalhe/61690reponame:Biblioteca Digital de Teses e Dissertações da Faculdade São Leopoldo Mandicinstname:Faculdade São Leopoldo Mandicinstacron:SLMANDICinfo:eu-repo/semantics/openAccess2022-08-26T19:57:41Zoai:prima.com.br:61690Biblioteca Digital de Teses e DissertaçõesPRIhttps://biblioteca.slmandic.edu.br/biblioteca/oai/oai.aspsamanta.capeletto@slmandic.edu.bropendoar:2022-08-26T19:57:41Biblioteca Digital de Teses e Dissertações da Faculdade São Leopoldo Mandic - Faculdade São Leopoldo Mandicfalse |
| dc.title.none.fl_str_mv |
Avaliação fotoelástica de estresse peri-implantar em função da inclinação do implante e da extensão do cantilever em próteses múltiplas |
| title |
Avaliação fotoelástica de estresse peri-implantar em função da inclinação do implante e da extensão do cantilever em próteses múltiplas |
| spellingShingle |
Avaliação fotoelástica de estresse peri-implantar em função da inclinação do implante e da extensão do cantilever em próteses múltiplas Mählmann, Vanessa de Fátima Silva dos Santos Implante dentário Prótese dentária |
| title_short |
Avaliação fotoelástica de estresse peri-implantar em função da inclinação do implante e da extensão do cantilever em próteses múltiplas |
| title_full |
Avaliação fotoelástica de estresse peri-implantar em função da inclinação do implante e da extensão do cantilever em próteses múltiplas |
| title_fullStr |
Avaliação fotoelástica de estresse peri-implantar em função da inclinação do implante e da extensão do cantilever em próteses múltiplas |
| title_full_unstemmed |
Avaliação fotoelástica de estresse peri-implantar em função da inclinação do implante e da extensão do cantilever em próteses múltiplas |
| title_sort |
Avaliação fotoelástica de estresse peri-implantar em função da inclinação do implante e da extensão do cantilever em próteses múltiplas |
| author |
Mählmann, Vanessa de Fátima Silva dos Santos |
| author_facet |
Mählmann, Vanessa de Fátima Silva dos Santos |
| author_role |
author |
| dc.contributor.none.fl_str_mv |
Vedovatto, Eduardo Centro de Pesquisas Odontológicas São Leopoldo Mandic |
| dc.contributor.author.fl_str_mv |
Mählmann, Vanessa de Fátima Silva dos Santos |
| dc.subject.por.fl_str_mv |
Implante dentário Prótese dentária |
| topic |
Implante dentário Prótese dentária |
| description |
Dissertação (Mestrado em Implantodontia) - Centro de Pesquisas Odontológicas São Leopoldo Mandic. |
| publishDate |
2013 |
| dc.date.none.fl_str_mv |
2013 |
| dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
| dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
| format |
masterThesis |
| status_str |
publishedVersion |
| dc.identifier.uri.fl_str_mv |
https://biblioteca.slmandic.edu.br/TerminalWebRI/acervo/detalhe/61690 |
| url |
https://biblioteca.slmandic.edu.br/TerminalWebRI/acervo/detalhe/61690 |
| dc.language.iso.fl_str_mv |
por |
| language |
por |
| dc.relation.none.fl_str_mv |
https://biblioteca.slmandic.edu.br/TerminalWebRI/acervo/detalhe/61690 |
| dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf 65 f. : il. |
| dc.publisher.none.fl_str_mv |
[s.n.] |
| publisher.none.fl_str_mv |
[s.n.] |
| dc.source.none.fl_str_mv |
reponame:Biblioteca Digital de Teses e Dissertações da Faculdade São Leopoldo Mandic instname:Faculdade São Leopoldo Mandic instacron:SLMANDIC |
| instname_str |
Faculdade São Leopoldo Mandic |
| instacron_str |
SLMANDIC |
| institution |
SLMANDIC |
| reponame_str |
Biblioteca Digital de Teses e Dissertações da Faculdade São Leopoldo Mandic |
| collection |
Biblioteca Digital de Teses e Dissertações da Faculdade São Leopoldo Mandic |
| repository.name.fl_str_mv |
Biblioteca Digital de Teses e Dissertações da Faculdade São Leopoldo Mandic - Faculdade São Leopoldo Mandic |
| repository.mail.fl_str_mv |
samanta.capeletto@slmandic.edu.br |
| _version_ |
1847096529624498176 |