Desenvolvimento de um equipamento portátil para verificação em campo de medidores de energia
| Ano de defesa: | 2020 |
|---|---|
| Autor(a) principal: | |
| Orientador(a): | |
| Banca de defesa: | |
| Tipo de documento: | Dissertação |
| Tipo de acesso: | Acesso aberto |
| Idioma: | por |
| Instituição de defesa: |
Universidade Federal de Minas Gerais
|
| Programa de Pós-Graduação: |
Não Informado pela instituição
|
| Departamento: |
Não Informado pela instituição
|
| País: |
Não Informado pela instituição
|
| Palavras-chave em Português: | |
| Link de acesso: | https://hdl.handle.net/1843/50456 |
Resumo: | It its presented the development of a portable and lightweight equipment for energy meter calibration on field, without relying on the use of a battery to ensure its operation, capable of performing all necessary tests required by current technical standards in Brazil, providing a significant cost reduction and shortening the duration of the whole current process. The instrument automates all tests, has its own load up to 50 A and prints, via Bluetooth printer, an on site technical report with the main information of the measurement process. Technical requirements for the device to be viable are presented. It is shown the advantages of its use, as well as a technical analysis of its main functionalities and relevant hardware and software resources. An equipment's MVP was calibrated by an accredited laboratory, having all its functionalities validated. It already has a commercially available model. It is an innovative, point-of-use market solution for the entire field calibration process, reducing costs and lead time related to a standard energy meter verification procedure. |
| id |
UFMG_e437b96fd6bd38d2d111c61dbcf36769 |
|---|---|
| oai_identifier_str |
oai:repositorio.ufmg.br:1843/50456 |
| network_acronym_str |
UFMG |
| network_name_str |
Repositório Institucional da UFMG |
| repository_id_str |
|
| spelling |
2023-02-27T17:51:04Z2025-09-09T00:01:41Z2023-02-27T17:51:04Z2020-02-17https://hdl.handle.net/1843/50456It its presented the development of a portable and lightweight equipment for energy meter calibration on field, without relying on the use of a battery to ensure its operation, capable of performing all necessary tests required by current technical standards in Brazil, providing a significant cost reduction and shortening the duration of the whole current process. The instrument automates all tests, has its own load up to 50 A and prints, via Bluetooth printer, an on site technical report with the main information of the measurement process. Technical requirements for the device to be viable are presented. It is shown the advantages of its use, as well as a technical analysis of its main functionalities and relevant hardware and software resources. An equipment's MVP was calibrated by an accredited laboratory, having all its functionalities validated. It already has a commercially available model. It is an innovative, point-of-use market solution for the entire field calibration process, reducing costs and lead time related to a standard energy meter verification procedure.porotherUniversidade Federal de Minas Geraishttp://creativecommons.org/licenses/by-nc-nd/3.0/pt/info:eu-repo/semantics/openAccessVerificação em campoInstrumento portátilPadrão de energiaIrregularidades e perdasCarga fantasmaEngenharia elétricaMedidores elétricosCalibraçãoDesenvolvimento de um equipamento portátil para verificação em campo de medidores de energiaDevelopment of a portable equipment for field verification of energy metersinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisJoão Vítor Marques Antunesreponame:Repositório Institucional da UFMGinstname:Universidade Federal de Minas Gerais (UFMG)instacron:UFMGhttp://lattes.cnpq.br/1438669062000920Clever Sebastião Pereira Filhohttp://lattes.cnpq.br/8189440518085762Carmela Maria Polito BragaLenin Martins Ferreira MoraisMaria Helena Murta ValeApresenta-se o desenvolvimento de um equipamento para verificação em campo de medidores de energia, portátil e leve, sem a dependência do uso de uma bateria para garantir seu funcionamento, capaz de executar os ensaios exigidos nas normas técnicas vigentes no Brasil, proporcionando uma redução significativa nos prazos e custos envolvidos no procedimento padrão atual. O instrumento automatiza todos os ensaios necessários, implementando a metodologia de inspeção e ensaios de verificação, possui capacidade de fornecimento de corrente de até 50 A e imprime, via impressora Bluetooth, um laudo técnico, in loco, com as principais informações do processo de verificação. São apresentados os requisitos técnicos necessários para que um instrumento deste tipo seja viável e como o verificador desenvolvido atende a estes requisitos. Evidencia-se as vantagens de sua utilização, bem como uma analise técnica, abordando suas principais funcionalidades e características relevantes de hardware e software, é realizada. Um MVP do equipamento foi calibrado por laboratório credenciado, tendo todas as suas funcionalidades validadas. Já possui modelo comercialmente disponível. Trata-se de uma solução inovadora no sentido de que seu uso reduz os custos e prazos relacionados a um procedimento padrão de verificação de medidores de energia.BrasilENG - DEPARTAMENTO DE ENGENHARIA ELÉTRICAPrograma de Pós-Graduação em Engenharia ElétricaUFMGORIGINALDissertação João V M Antunes pdfa.pdfapplication/pdf13077445https://repositorio.ufmg.br//bitstreams/90b3f0b0-3f94-4815-b4fa-c9e9c4fee9e6/downloadf17ae57a559f624d16c2cf83c9a54ac5MD51trueAnonymousREADLICENSElicense.txttext/plain2118https://repositorio.ufmg.br//bitstreams/58f8fe4f-8e08-4456-b20e-623db038b333/downloadcda590c95a0b51b4d15f60c9642ca272MD52falseAnonymousREADCC-LICENSElicense_rdfapplication/octet-stream811https://repositorio.ufmg.br//bitstreams/6d115637-84ef-4c7e-bf2f-dc9c6a2d986d/downloadcfd6801dba008cb6adbd9838b81582abMD53falseAnonymousREAD1843/504562025-09-08 21:01:41.342http://creativecommons.org/licenses/by-nc-nd/3.0/pt/Acesso Abertoopen.accessoai:repositorio.ufmg.br:1843/50456https://repositorio.ufmg.br/Repositório InstitucionalPUBhttps://repositorio.ufmg.br/oairepositorio@ufmg.bropendoar:2025-09-09T00:01:41Repositório Institucional da UFMG - Universidade Federal de Minas Gerais (UFMG)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 |
| dc.title.none.fl_str_mv |
Desenvolvimento de um equipamento portátil para verificação em campo de medidores de energia |
| dc.title.alternative.none.fl_str_mv |
Development of a portable equipment for field verification of energy meters |
| title |
Desenvolvimento de um equipamento portátil para verificação em campo de medidores de energia |
| spellingShingle |
Desenvolvimento de um equipamento portátil para verificação em campo de medidores de energia João Vítor Marques Antunes Engenharia elétrica Medidores elétricos Calibração Verificação em campo Instrumento portátil Padrão de energia Irregularidades e perdas Carga fantasma |
| title_short |
Desenvolvimento de um equipamento portátil para verificação em campo de medidores de energia |
| title_full |
Desenvolvimento de um equipamento portátil para verificação em campo de medidores de energia |
| title_fullStr |
Desenvolvimento de um equipamento portátil para verificação em campo de medidores de energia |
| title_full_unstemmed |
Desenvolvimento de um equipamento portátil para verificação em campo de medidores de energia |
| title_sort |
Desenvolvimento de um equipamento portátil para verificação em campo de medidores de energia |
| author |
João Vítor Marques Antunes |
| author_facet |
João Vítor Marques Antunes |
| author_role |
author |
| dc.contributor.author.fl_str_mv |
João Vítor Marques Antunes |
| dc.subject.por.fl_str_mv |
Engenharia elétrica Medidores elétricos Calibração |
| topic |
Engenharia elétrica Medidores elétricos Calibração Verificação em campo Instrumento portátil Padrão de energia Irregularidades e perdas Carga fantasma |
| dc.subject.other.none.fl_str_mv |
Verificação em campo Instrumento portátil Padrão de energia Irregularidades e perdas Carga fantasma |
| description |
It its presented the development of a portable and lightweight equipment for energy meter calibration on field, without relying on the use of a battery to ensure its operation, capable of performing all necessary tests required by current technical standards in Brazil, providing a significant cost reduction and shortening the duration of the whole current process. The instrument automates all tests, has its own load up to 50 A and prints, via Bluetooth printer, an on site technical report with the main information of the measurement process. Technical requirements for the device to be viable are presented. It is shown the advantages of its use, as well as a technical analysis of its main functionalities and relevant hardware and software resources. An equipment's MVP was calibrated by an accredited laboratory, having all its functionalities validated. It already has a commercially available model. It is an innovative, point-of-use market solution for the entire field calibration process, reducing costs and lead time related to a standard energy meter verification procedure. |
| publishDate |
2020 |
| dc.date.issued.fl_str_mv |
2020-02-17 |
| dc.date.accessioned.fl_str_mv |
2023-02-27T17:51:04Z 2025-09-09T00:01:41Z |
| dc.date.available.fl_str_mv |
2023-02-27T17:51:04Z |
| dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
| dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
| format |
masterThesis |
| status_str |
publishedVersion |
| dc.identifier.uri.fl_str_mv |
https://hdl.handle.net/1843/50456 |
| url |
https://hdl.handle.net/1843/50456 |
| dc.language.iso.fl_str_mv |
por other |
| language |
por |
| language_invalid_str_mv |
other |
| dc.rights.driver.fl_str_mv |
http://creativecommons.org/licenses/by-nc-nd/3.0/pt/ info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
http://creativecommons.org/licenses/by-nc-nd/3.0/pt/ |
| eu_rights_str_mv |
openAccess |
| dc.publisher.none.fl_str_mv |
Universidade Federal de Minas Gerais |
| publisher.none.fl_str_mv |
Universidade Federal de Minas Gerais |
| dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UFMG instname:Universidade Federal de Minas Gerais (UFMG) instacron:UFMG |
| instname_str |
Universidade Federal de Minas Gerais (UFMG) |
| instacron_str |
UFMG |
| institution |
UFMG |
| reponame_str |
Repositório Institucional da UFMG |
| collection |
Repositório Institucional da UFMG |
| bitstream.url.fl_str_mv |
https://repositorio.ufmg.br//bitstreams/90b3f0b0-3f94-4815-b4fa-c9e9c4fee9e6/download https://repositorio.ufmg.br//bitstreams/58f8fe4f-8e08-4456-b20e-623db038b333/download https://repositorio.ufmg.br//bitstreams/6d115637-84ef-4c7e-bf2f-dc9c6a2d986d/download |
| bitstream.checksum.fl_str_mv |
f17ae57a559f624d16c2cf83c9a54ac5 cda590c95a0b51b4d15f60c9642ca272 cfd6801dba008cb6adbd9838b81582ab |
| bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 |
| repository.name.fl_str_mv |
Repositório Institucional da UFMG - Universidade Federal de Minas Gerais (UFMG) |
| repository.mail.fl_str_mv |
repositorio@ufmg.br |
| _version_ |
1862105761450033152 |