Acurácia do BiliUFPR® : um analisador de bilirrubina transcutânea na avaliação de icterícia neonatal

Detalhes bibliográficos
Ano de defesa: 2017
Autor(a) principal: Povaluk, Patricia
Orientador(a): Sarquis, Ana Lúcia Figueiredo
Banca de defesa: Não Informado pela instituição
Tipo de documento: Dissertação
Tipo de acesso: Acesso aberto
Idioma: por
Instituição de defesa: Não Informado pela instituição
Programa de Pós-Graduação: Não Informado pela instituição
Departamento: Não Informado pela instituição
País: Não Informado pela instituição
Palavras-chave em Português:
Link de acesso: http://hdl.handle.net/1884/53401
Resumo: Orientadora: Profª. Drª. Ana Lúcia Figueiredo Sarquis
id UFPR_d3d0e39c70c10e85e7790cc1ddd24b03
oai_identifier_str oai:acervodigital.ufpr.br:1884/53401
network_acronym_str UFPR
network_name_str Repositório Institucional da UFPR
repository_id_str
spelling Povaluk, PatriciaCat, Monica Nunes LimaUniversidade Federal do Paraná. Setor de Ciências da Saúde. Programa de Pós-Graduação em Saúde da Criança e do AdolescenteSarquis, Ana Lúcia Figueiredo2018-05-15T22:04:48Z2018-05-15T22:04:48Z2017http://hdl.handle.net/1884/53401Orientadora: Profª. Drª. Ana Lúcia Figueiredo SarquisCoorientadora: Profª. Drª. Mônica Nunes Lima CatDissertação (mestrado) - Universidade Federal do Paraná, Setor de Ciências da Saúde, Programa de Pós-Graduação em Saúde da Criança e do Adolescente. Defesa: Curitiba, 13/12/2017Inclui referências : f.90-101Resumo: A icterícia é um dos problemas mais frequentes em neonatos. A avaliação transcutânea da bilirrubina propicia medidas rápidas, indolores e sem espoliação sanguínea. Entretanto, o alto custo dos bilirrubinômetros dificulta a sua ampla utilização. O objetivo principal deste estudo foi verificar a acurácia do BiliUFPR®, analisador transcutâneo de bilirrubina desenvolvido na Universidade Federal do Paraná (UFPR) com materiais nacionais e de baixo custo. Avaliou-se também a acurácia do JM-105®, bilirrubinômetro utilizado na rotina do Serviço de Neonatologia do Complexo Hospital de Clínicas da UFPR (CHC-UFPR) e a possível interferência de algumas características dos recém-nascidos (RN) nas medidas. Material e métodos: Foram avaliados 221 RN, em duas etapas de coleta de dados. Na primeira etapa foram realizadas 105 comparações entre medidas séricas e transcutâneas de bilirrubina realizadas com o BiliUFPR®. A partir destes resultados, foram efetuados ajustes técnicos no aparelho, e então procedeu-se a uma nova etapa de coleta de dados. Na segunda etapa, foram incluídas medidas transcutâneas de bilirrubina (BTc) realizadas com o analisador JM-105®. Nesta etapa foram realizadas 185 comparações entre os dois aparelhos, em 101 destas comparações pareadas obteve-se também a bilirrubina sérica (BTs). Para a avaliação da concordância entre as medidas foi aplicado o coeficiente de correlação de Pearson. Resultados: A média da idade gestacional da amostra foi 36,4 +3,0 semanas, do peso de nascimento 2775,9g +762,1, 80,1% apresentavam ? 3 dias de vida. Inicialmente a correlação entre a BTc realizada com o BiliUFPR® com a BTs foi fraca (r = 0,39 frontal e r = 0,41 esternal). Após os ajustes técnicos no aparelho, a correlação aumentou para 0,57 na fronte e 0,58 no esterno e a diferença média entre as medidas foi de -2,1 mg/dL. A acurácia do BiliUFPR® foi maior para valores mais baixos de bilirrulina, sendo 8 mg/dL o ponto de corte de melhor acurácia (84,1%). As medidas realizadas com o JM-105® apresentaram coeficiente de correlação de 0,91 com a BTs, com diferença média de 0,1 mg/dL entre as medidas, sendo que estas não sofreram interferência do peso de nascimento e da idade gestacional e pós-natal. O coeficiente de correlação entre os dois aparelhos foi de 0,66. Conclusões: A bilirrubina transcutânea realizada com o BiliUFPR® apresentou correlação moderada com a bilirrubina sérica, a melhor acurácia deste aparelho foi para valores baixos de bilirrubina, enquanto o JM-105® apresentou correlação muito forte e acurácia alta em todos os valores avaliados. Faz-se necessário o aprimoramento do BiliUFPR® na tentativa de produzir um aparelho com melhor acurácia, e ainda assim custo acessível. Palavras-chave: bilirrubina transcutânea, icterícia, recém-nascidoAbstract: Jaundice is one of the most common disorders in neonates. Transcutaneous evaluation of bilirubin provides rapid, painless and no blood spoliation measures. However, the high bilirubinometer's cost makes its wide use difficult. The main objective of this study was to verify the accuracy of BiliUFPR®, a transcutaneous bilirubin analyzer developed in the Universidade Federal do Paraná (UFPR) with national and low-cost materials. The accuracy of JM-105® bilirubinometer device that is used in the routine of the Serviço de Neonatologia do Complexo Hospital de Clínicas da UFPR (CHC-UFPR) and the possible interference of neonatal characteristics in the transcutaneous bilirubin measurements were also evaluated. Materials and methods: A total of 221 newborns were evaluated in two phases of data collection. In the first phase, 105 comparisons were made between serum and transcutaneous bilirubin measurements performed with BiliUFPR®, from these initial results, technical improvements in BiliUFPR® were made, and then a second phase of data collection was carried out. In the second phase, transcutaneous bilirubin (BTc) measurements performed with JM-105® were also included. In this phase, 185 comparisons were made between the two devices, in 101 of these comparisons, serum bilirubin (BTs) was also obtained. To analyze the agreement between the measurements, Pearson correlation was applied. Results: The mean gestational age of the sample was 36.4 +3.0 weeks, the birth weight was 2775.9 g +762.1, 80.1% were ? 3 days of life. Firstly, the correlation between BTc performed with BiliUFPR® and BTs was weak (r = 0.39 on the forehead and r = 0.41 on the sternum). After technical improvements in this device, the correlation increased to 0.57 on the forehead and 0.58 on the sternum and the mean difference between the measurements was -2.1 mg/dL. The accuracy of BiliUFPR® was higher for lower bilirubin measurements, 8 mg/dL was the best accuracy cutoff point (84.1%). The measurements performed with JM-105® showed a correlation of 0.91 with BTs, and the mean difference was 0.1 mg/dL. These measurements were not affected by the newborns' weight, gestational and postnatal age. The correlation between the two devices was 0,66. Conclusions: Transcutaneous bilirubin performed with BiliUFPR® showed a moderate correlation with serum bilirubin, however the highest accuracy was for lower bilirubin values, while JM-105® device showed a very strong correlation between serum and transcutaneous measurements and high accuracy in all values evaluated. Improvements in BiliUFPR® device will be necessary in order to produce a more accurate device and still within an affordable cost. Key words: transcutaneous bilirubin, jaundice, newborn115 f. : il. algumas color., gráfs., tabs.application/pdfPediatriaBilirrubinaIctericiaRecém-nascidosAcurácia do BiliUFPR® : um analisador de bilirrubina transcutânea na avaliação de icterícia neonatalinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisporreponame:Repositório Institucional da UFPRinstname:Universidade Federal do Paraná (UFPR)instacron:UFPRinfo:eu-repo/semantics/openAccessORIGINALR - D - PATRICIA POVALUK.pdfapplication/pdf4663746https://acervodigital.ufpr.br/bitstream/1884/53401/1/R%20-%20D%20-%20PATRICIA%20POVALUK.pdfb3e40a4dff64ccc36d110487745a7eefMD51open access1884/534012018-05-15 19:04:48.143open accessoai:acervodigital.ufpr.br:1884/53401Repositório InstitucionalPUBhttp://acervodigital.ufpr.br/oai/requestinformacaodigital@ufpr.bropendoar:3082018-05-15T22:04:48Repositório Institucional da UFPR - Universidade Federal do Paraná (UFPR)false
dc.title.pt_BR.fl_str_mv Acurácia do BiliUFPR® : um analisador de bilirrubina transcutânea na avaliação de icterícia neonatal
title Acurácia do BiliUFPR® : um analisador de bilirrubina transcutânea na avaliação de icterícia neonatal
spellingShingle Acurácia do BiliUFPR® : um analisador de bilirrubina transcutânea na avaliação de icterícia neonatal
Povaluk, Patricia
Pediatria
Bilirrubina
Ictericia
Recém-nascidos
title_short Acurácia do BiliUFPR® : um analisador de bilirrubina transcutânea na avaliação de icterícia neonatal
title_full Acurácia do BiliUFPR® : um analisador de bilirrubina transcutânea na avaliação de icterícia neonatal
title_fullStr Acurácia do BiliUFPR® : um analisador de bilirrubina transcutânea na avaliação de icterícia neonatal
title_full_unstemmed Acurácia do BiliUFPR® : um analisador de bilirrubina transcutânea na avaliação de icterícia neonatal
title_sort Acurácia do BiliUFPR® : um analisador de bilirrubina transcutânea na avaliação de icterícia neonatal
author Povaluk, Patricia
author_facet Povaluk, Patricia
author_role author
dc.contributor.other.pt_BR.fl_str_mv Cat, Monica Nunes Lima
Universidade Federal do Paraná. Setor de Ciências da Saúde. Programa de Pós-Graduação em Saúde da Criança e do Adolescente
dc.contributor.author.fl_str_mv Povaluk, Patricia
dc.contributor.advisor1.fl_str_mv Sarquis, Ana Lúcia Figueiredo
contributor_str_mv Sarquis, Ana Lúcia Figueiredo
dc.subject.por.fl_str_mv Pediatria
Bilirrubina
Ictericia
Recém-nascidos
topic Pediatria
Bilirrubina
Ictericia
Recém-nascidos
description Orientadora: Profª. Drª. Ana Lúcia Figueiredo Sarquis
publishDate 2017
dc.date.issued.fl_str_mv 2017
dc.date.accessioned.fl_str_mv 2018-05-15T22:04:48Z
dc.date.available.fl_str_mv 2018-05-15T22:04:48Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/1884/53401
url http://hdl.handle.net/1884/53401
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 115 f. : il. algumas color., gráfs., tabs.
application/pdf
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFPR
instname:Universidade Federal do Paraná (UFPR)
instacron:UFPR
instname_str Universidade Federal do Paraná (UFPR)
instacron_str UFPR
institution UFPR
reponame_str Repositório Institucional da UFPR
collection Repositório Institucional da UFPR
bitstream.url.fl_str_mv https://acervodigital.ufpr.br/bitstream/1884/53401/1/R%20-%20D%20-%20PATRICIA%20POVALUK.pdf
bitstream.checksum.fl_str_mv b3e40a4dff64ccc36d110487745a7eef
bitstream.checksumAlgorithm.fl_str_mv MD5
repository.name.fl_str_mv Repositório Institucional da UFPR - Universidade Federal do Paraná (UFPR)
repository.mail.fl_str_mv informacaodigital@ufpr.br
_version_ 1847526148793171968