Limas mecanizadas desenvolvidas para dentes decíduos comparada as convencionais, na instrumentação, tempo de preparo e qualidade de diferentes técnicas obturadoras em protótipos resinosos
| Ano de defesa: | 2025 |
|---|---|
| Autor(a) principal: | |
| Orientador(a): | |
| Banca de defesa: | |
| Tipo de documento: | Tese |
| Tipo de acesso: | Acesso aberto |
| Idioma: | por |
| Instituição de defesa: |
Biblioteca Digitais de Teses e Dissertações da USP
|
| Programa de Pós-Graduação: |
Não Informado pela instituição
|
| Departamento: |
Não Informado pela instituição
|
| País: |
Não Informado pela instituição
|
| Palavras-chave em Português: | |
| Link de acesso: | https://www.teses.usp.br/teses/disponiveis/25/25145/tde-05022026-154007/ |
Resumo: | A Endodontia tem apresentado avanços substanciais nos últimos anos, com o aprimoramento de técnicas e o desenvolvimento de novos materiais. Entretanto, apesar da modernização relevante pouco se tem sobre instrumentos mecanizados desenvolvidos especificamente para dentes decíduos e sobre diferentes técnicas obturadoras para os mesmos. Dessa forma, o objetivo deste trabalho foi avaliar o tempo e preparo biomecânico realizado com lima rotatória odontopediátrica (Sequence Baby File SBF) e compará-la com limas manuais e mecanizadas convencionais, bem como a qualidade de diferentes técnicas obturadoras em protótipos de molares decíduos. De início, foram necessários 150 canais de um segundo molar decíduo prototipado. A amostra foi escaneada pelo sistema de MicroCT e dividida aleatoriamente em 5 grupos, de acordo com a instrumentação: Lima K (G1), Lima manual M (G2), SBF (G3), ProDesign Logic 2 rotatória (G4) e ProDesign Logic 2 reciprocante (G5). O tempo efetivo de instrumentação foi cronometrado. Após o preparo, um novo escaneamento foi realizado. As medidas de desvio do canal radicular, quantidade de resina remanescente, paredes não tocadas, formação de degraus e perfurações radiculares foram realizadas. Para avaliação da qualidade de obturação, 80 canais de um segundo molar decíduo foram escaneados pelo sistema de MicroCT e divididos em 2 grupos: instrumentados pela Lima K e SBF. Após o preparo, a amostra foi escaneada novamente, e através do software do próprio microtomógrafo o aumento do volume do canal radicular foi calculado. Os 40 canais instrumentados pela SBF foram divididos aleatoriamente em 4 grupos, de acordo com a técnica obturadora: pontas endodônticas descartáveis, lima K, lentulo e ultrassom. Todos foram obturados com pasta endodôntica de hidróxido de cálcio e iodofórmio. Como controle, o mesmo foi realizado nos 40 canais instrumentados com a lima K. Após obturados, um novo escaneamento foi realizado e o percentual volumétrico de áreas de vazios foi obtido. Os dados foram submetidos a análises estatísticas com nível de significância de 5%. Não houve diferença no desvio do canal radicular. Na quantidade de resina removida, G4 apresentou menores desgastes no terço apical, G1 os maiores desgastes no terço médio e no terço cervical não houve diferença entre os grupos. Na porcentagem de paredes não tocadas, G5 apresentou os maiores valores. Não houve diferença estatística para perfurações e degraus. G1 apresentou os maiores tempos de instrumentação. Tanto a lima K quanto a SBF promoveram aumentos semelhantes do volume do canal radicular, sem diferenças estatísticas entre elas. Na obturação, em relação a porcentagem de área de vazio, não houve diferença entre o tipo de lima utilizada na instrumentação, assim como não houve diferença entre as técnicas obturadoras. Com desvio e porcentagem de parede tocadas semelhante aos demais instrumentos e tempo de preparo comparável as limas mecanizadas, as limas manuais de níquel-titânio apresentam-se como uma opção promissora para a instrumentação em dentes decíduos. E preparos endodônticos promotores de aumento do volume do canal radicular, que permitam o devido escoamento da pasta obturadora, aparentam ser mais relevantes para o correto preenchimento do canal do que a técnica utilizada. |
| id |
USP_092ddc2b7641d6aa3f5578d5e351458f |
|---|---|
| oai_identifier_str |
oai:teses.usp.br:tde-05022026-154007 |
| network_acronym_str |
USP |
| network_name_str |
Biblioteca Digital de Teses e Dissertações da USP |
| repository_id_str |
|
| spelling |
Limas mecanizadas desenvolvidas para dentes decíduos comparada as convencionais, na instrumentação, tempo de preparo e qualidade de diferentes técnicas obturadoras em protótipos resinososMechanized files developed for deciduous teeth compared to conventional in instrumentation, preparation time and quality of different obturation techniques in resin prototypesDente decíduoMicrotomografia por Raio-XPrimary teethPulpectomiaPulpectomyX-Ray microtomographyA Endodontia tem apresentado avanços substanciais nos últimos anos, com o aprimoramento de técnicas e o desenvolvimento de novos materiais. Entretanto, apesar da modernização relevante pouco se tem sobre instrumentos mecanizados desenvolvidos especificamente para dentes decíduos e sobre diferentes técnicas obturadoras para os mesmos. Dessa forma, o objetivo deste trabalho foi avaliar o tempo e preparo biomecânico realizado com lima rotatória odontopediátrica (Sequence Baby File SBF) e compará-la com limas manuais e mecanizadas convencionais, bem como a qualidade de diferentes técnicas obturadoras em protótipos de molares decíduos. De início, foram necessários 150 canais de um segundo molar decíduo prototipado. A amostra foi escaneada pelo sistema de MicroCT e dividida aleatoriamente em 5 grupos, de acordo com a instrumentação: Lima K (G1), Lima manual M (G2), SBF (G3), ProDesign Logic 2 rotatória (G4) e ProDesign Logic 2 reciprocante (G5). O tempo efetivo de instrumentação foi cronometrado. Após o preparo, um novo escaneamento foi realizado. As medidas de desvio do canal radicular, quantidade de resina remanescente, paredes não tocadas, formação de degraus e perfurações radiculares foram realizadas. Para avaliação da qualidade de obturação, 80 canais de um segundo molar decíduo foram escaneados pelo sistema de MicroCT e divididos em 2 grupos: instrumentados pela Lima K e SBF. Após o preparo, a amostra foi escaneada novamente, e através do software do próprio microtomógrafo o aumento do volume do canal radicular foi calculado. Os 40 canais instrumentados pela SBF foram divididos aleatoriamente em 4 grupos, de acordo com a técnica obturadora: pontas endodônticas descartáveis, lima K, lentulo e ultrassom. Todos foram obturados com pasta endodôntica de hidróxido de cálcio e iodofórmio. Como controle, o mesmo foi realizado nos 40 canais instrumentados com a lima K. Após obturados, um novo escaneamento foi realizado e o percentual volumétrico de áreas de vazios foi obtido. Os dados foram submetidos a análises estatísticas com nível de significância de 5%. Não houve diferença no desvio do canal radicular. Na quantidade de resina removida, G4 apresentou menores desgastes no terço apical, G1 os maiores desgastes no terço médio e no terço cervical não houve diferença entre os grupos. Na porcentagem de paredes não tocadas, G5 apresentou os maiores valores. Não houve diferença estatística para perfurações e degraus. G1 apresentou os maiores tempos de instrumentação. Tanto a lima K quanto a SBF promoveram aumentos semelhantes do volume do canal radicular, sem diferenças estatísticas entre elas. Na obturação, em relação a porcentagem de área de vazio, não houve diferença entre o tipo de lima utilizada na instrumentação, assim como não houve diferença entre as técnicas obturadoras. Com desvio e porcentagem de parede tocadas semelhante aos demais instrumentos e tempo de preparo comparável as limas mecanizadas, as limas manuais de níquel-titânio apresentam-se como uma opção promissora para a instrumentação em dentes decíduos. E preparos endodônticos promotores de aumento do volume do canal radicular, que permitam o devido escoamento da pasta obturadora, aparentam ser mais relevantes para o correto preenchimento do canal do que a técnica utilizada.Endodontics has had great evolution in recent years, with advances in techniques and development of new materials. Despite relevant modernization, little is known about rotary instruments developed specifically for primary teeth, and about different obturation techniques in them. Thus, this work aimed to evaluate the time and biomechanical preparation performed with a file developed for deciduous teeth (Sequence Baby File - SBF) and compare it with different instrumentation techniques, as well as the quality of different obturation techniques in prototypes of deciduous molars. For this, 150 canals of a prototyped deciduous second molar were scanned by the MicroCT system and randomly divided into 5 groups, according to instrumentation: K file (G1), manual M (G2), SBF (G3), ProDesign Logic 2 rotary (G4) and ProDesign Logic 2 reciprocating files (G5). The effective time of Instrumentation was measured. After preparation, a new scan was realized. Measurements of root canal transportation, amount of resin remaining, touched and untouched walls, ledge formation and root perforations were performed. For evaluation of the obturation quality, 80 canals of a prototyped deciduous second molar were scanned by the MicroCT system and randomly divided into 2 groups: instrumented by K file and SBF. After preparation, a new scan was realized and through the microtomograph\'s own software the increase in root canal volume was calculated. The 40 canals instrumented with SBF were divided into 4 groups: disposable endodontic tips, K file, lentulo and ultrasound. All were filled with endodontic paste of calcium hydroxide and iodoform. As a control, the same was performed on the 40 canals instrumented with the K-file. After filling, a final scan was realized and the volumetric percentage of internal voids was obtained. The data were subjected to statistical analysis, considering a 5% level of significance. There was no statistically significant difference in root canal deviation. The analysis of the amount of resin removed indicates that in the apical third, G4 had the least resin wear, in the middle third, G1 exhibited the most wear and no difference was observed in the cervical third. G5 had the highest percentage of untouched walls. There was no significant difference in perforations and steps among the groups. G1 took the longest time for instrumentation compared to the other groups. Both the K-file and the SBF promoted similar increases in root canal volume, with no statistical differences between them. In obturation, in relation to the percentage of internal voids there was no difference between the type of file used in the instrumentation, just as there was no difference between the obturation techniques. With deviation and percentage of wall touched similar to other instruments and preparation time comparable to mechanized files, nickel-titanium manual files are promising for endodontic preparation in deciduous teeth. And endodontic preparations that promote an increase in the volume of the root canal, which allow the proper flow of the filling paste, appear to be more relevant for the correct filling of the canal than the technique used.Biblioteca Digitais de Teses e Dissertações da USPLourenço Neto, NatalinoSouza, Bianca Katsumata de2025-10-31info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisapplication/pdfhttps://www.teses.usp.br/teses/disponiveis/25/25145/tde-05022026-154007/reponame:Biblioteca Digital de Teses e Dissertações da USPinstname:Universidade de São Paulo (USP)instacron:USPReter o conteúdo por motivos de patente, publicação e/ou direitos autoriais.info:eu-repo/semantics/openAccesspor2026-02-23T17:27:02Zoai:teses.usp.br:tde-05022026-154007Biblioteca Digital de Teses e Dissertaçõeshttp://www.teses.usp.br/PUBhttp://www.teses.usp.br/cgi-bin/mtd2br.plvirginia@if.usp.br|| atendimento@aguia.usp.br||virginia@if.usp.bropendoar:27212026-02-23T17:27:02Biblioteca Digital de Teses e Dissertações da USP - Universidade de São Paulo (USP)false |
| dc.title.none.fl_str_mv |
Limas mecanizadas desenvolvidas para dentes decíduos comparada as convencionais, na instrumentação, tempo de preparo e qualidade de diferentes técnicas obturadoras em protótipos resinosos Mechanized files developed for deciduous teeth compared to conventional in instrumentation, preparation time and quality of different obturation techniques in resin prototypes |
| title |
Limas mecanizadas desenvolvidas para dentes decíduos comparada as convencionais, na instrumentação, tempo de preparo e qualidade de diferentes técnicas obturadoras em protótipos resinosos |
| spellingShingle |
Limas mecanizadas desenvolvidas para dentes decíduos comparada as convencionais, na instrumentação, tempo de preparo e qualidade de diferentes técnicas obturadoras em protótipos resinosos Souza, Bianca Katsumata de Dente decíduo Microtomografia por Raio-X Primary teeth Pulpectomia Pulpectomy X-Ray microtomography |
| title_short |
Limas mecanizadas desenvolvidas para dentes decíduos comparada as convencionais, na instrumentação, tempo de preparo e qualidade de diferentes técnicas obturadoras em protótipos resinosos |
| title_full |
Limas mecanizadas desenvolvidas para dentes decíduos comparada as convencionais, na instrumentação, tempo de preparo e qualidade de diferentes técnicas obturadoras em protótipos resinosos |
| title_fullStr |
Limas mecanizadas desenvolvidas para dentes decíduos comparada as convencionais, na instrumentação, tempo de preparo e qualidade de diferentes técnicas obturadoras em protótipos resinosos |
| title_full_unstemmed |
Limas mecanizadas desenvolvidas para dentes decíduos comparada as convencionais, na instrumentação, tempo de preparo e qualidade de diferentes técnicas obturadoras em protótipos resinosos |
| title_sort |
Limas mecanizadas desenvolvidas para dentes decíduos comparada as convencionais, na instrumentação, tempo de preparo e qualidade de diferentes técnicas obturadoras em protótipos resinosos |
| author |
Souza, Bianca Katsumata de |
| author_facet |
Souza, Bianca Katsumata de |
| author_role |
author |
| dc.contributor.none.fl_str_mv |
Lourenço Neto, Natalino |
| dc.contributor.author.fl_str_mv |
Souza, Bianca Katsumata de |
| dc.subject.por.fl_str_mv |
Dente decíduo Microtomografia por Raio-X Primary teeth Pulpectomia Pulpectomy X-Ray microtomography |
| topic |
Dente decíduo Microtomografia por Raio-X Primary teeth Pulpectomia Pulpectomy X-Ray microtomography |
| description |
A Endodontia tem apresentado avanços substanciais nos últimos anos, com o aprimoramento de técnicas e o desenvolvimento de novos materiais. Entretanto, apesar da modernização relevante pouco se tem sobre instrumentos mecanizados desenvolvidos especificamente para dentes decíduos e sobre diferentes técnicas obturadoras para os mesmos. Dessa forma, o objetivo deste trabalho foi avaliar o tempo e preparo biomecânico realizado com lima rotatória odontopediátrica (Sequence Baby File SBF) e compará-la com limas manuais e mecanizadas convencionais, bem como a qualidade de diferentes técnicas obturadoras em protótipos de molares decíduos. De início, foram necessários 150 canais de um segundo molar decíduo prototipado. A amostra foi escaneada pelo sistema de MicroCT e dividida aleatoriamente em 5 grupos, de acordo com a instrumentação: Lima K (G1), Lima manual M (G2), SBF (G3), ProDesign Logic 2 rotatória (G4) e ProDesign Logic 2 reciprocante (G5). O tempo efetivo de instrumentação foi cronometrado. Após o preparo, um novo escaneamento foi realizado. As medidas de desvio do canal radicular, quantidade de resina remanescente, paredes não tocadas, formação de degraus e perfurações radiculares foram realizadas. Para avaliação da qualidade de obturação, 80 canais de um segundo molar decíduo foram escaneados pelo sistema de MicroCT e divididos em 2 grupos: instrumentados pela Lima K e SBF. Após o preparo, a amostra foi escaneada novamente, e através do software do próprio microtomógrafo o aumento do volume do canal radicular foi calculado. Os 40 canais instrumentados pela SBF foram divididos aleatoriamente em 4 grupos, de acordo com a técnica obturadora: pontas endodônticas descartáveis, lima K, lentulo e ultrassom. Todos foram obturados com pasta endodôntica de hidróxido de cálcio e iodofórmio. Como controle, o mesmo foi realizado nos 40 canais instrumentados com a lima K. Após obturados, um novo escaneamento foi realizado e o percentual volumétrico de áreas de vazios foi obtido. Os dados foram submetidos a análises estatísticas com nível de significância de 5%. Não houve diferença no desvio do canal radicular. Na quantidade de resina removida, G4 apresentou menores desgastes no terço apical, G1 os maiores desgastes no terço médio e no terço cervical não houve diferença entre os grupos. Na porcentagem de paredes não tocadas, G5 apresentou os maiores valores. Não houve diferença estatística para perfurações e degraus. G1 apresentou os maiores tempos de instrumentação. Tanto a lima K quanto a SBF promoveram aumentos semelhantes do volume do canal radicular, sem diferenças estatísticas entre elas. Na obturação, em relação a porcentagem de área de vazio, não houve diferença entre o tipo de lima utilizada na instrumentação, assim como não houve diferença entre as técnicas obturadoras. Com desvio e porcentagem de parede tocadas semelhante aos demais instrumentos e tempo de preparo comparável as limas mecanizadas, as limas manuais de níquel-titânio apresentam-se como uma opção promissora para a instrumentação em dentes decíduos. E preparos endodônticos promotores de aumento do volume do canal radicular, que permitam o devido escoamento da pasta obturadora, aparentam ser mais relevantes para o correto preenchimento do canal do que a técnica utilizada. |
| publishDate |
2025 |
| dc.date.none.fl_str_mv |
2025-10-31 |
| dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
| dc.type.driver.fl_str_mv |
info:eu-repo/semantics/doctoralThesis |
| format |
doctoralThesis |
| status_str |
publishedVersion |
| dc.identifier.uri.fl_str_mv |
https://www.teses.usp.br/teses/disponiveis/25/25145/tde-05022026-154007/ |
| url |
https://www.teses.usp.br/teses/disponiveis/25/25145/tde-05022026-154007/ |
| dc.language.iso.fl_str_mv |
por |
| language |
por |
| dc.relation.none.fl_str_mv |
|
| dc.rights.driver.fl_str_mv |
Reter o conteúdo por motivos de patente, publicação e/ou direitos autoriais. info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
Reter o conteúdo por motivos de patente, publicação e/ou direitos autoriais. |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.coverage.none.fl_str_mv |
|
| dc.publisher.none.fl_str_mv |
Biblioteca Digitais de Teses e Dissertações da USP |
| publisher.none.fl_str_mv |
Biblioteca Digitais de Teses e Dissertações da USP |
| dc.source.none.fl_str_mv |
reponame:Biblioteca Digital de Teses e Dissertações da USP instname:Universidade de São Paulo (USP) instacron:USP |
| instname_str |
Universidade de São Paulo (USP) |
| instacron_str |
USP |
| institution |
USP |
| reponame_str |
Biblioteca Digital de Teses e Dissertações da USP |
| collection |
Biblioteca Digital de Teses e Dissertações da USP |
| repository.name.fl_str_mv |
Biblioteca Digital de Teses e Dissertações da USP - Universidade de São Paulo (USP) |
| repository.mail.fl_str_mv |
virginia@if.usp.br|| atendimento@aguia.usp.br||virginia@if.usp.br |
| _version_ |
1865492427130798080 |